2905909
SKU
PHX2905909
MPN
TRIO-UPS-2G/1AC/1AC/230V/750VA
Weight
6.355 kg
This product is Not Cancellable/Not Returnable
Series TRIO-UPS
TRIO-UPS-2G/1AC/1AC/230V/750VA - Uninterruptible power supply
1AC/1AC/750 VA uninterruptible power supply with integrated battery, lead AGM, VRLA technology, 24 V DC, 4 Ah for 230 V AC applications.
- Smooth transition, thanks to the pure sine curve: the sine generated in battery operation is synchronous with the mains previously used for supply
- Space saving: Combination of UPS module and battery in the same housing
- Long buffer times with integrated VRLA battery, can be extended with additional battery module
- USB interface for connection to higher-level controllers such as industrial PCs
- Startup from energy storage possible, even without mains input
Technical Specifications
General
| Note on the battery | This product contains a battery with a limited shelf life that must be charged every few months. The product packaging indicates when the battery must be started up or recharged. The general shelf life can be found in the technical data area under “Latest startup”. |
AC operation
| Input Voltage | 230 V AC |
| Input voltage range | 184 V AC ... 264 V AC |
| Voltage type of supply voltage | AC |
| Frequency range (fN) | 45 Hz ... 55 Hz |
| Frequency range (fN) | 55 Hz ... 65 Hz |
| Current consumption | 3 A (max.) |
| Power factor (cos phi) | 0.8 |
| Input fuse | 10 A 400 V gRL |
| Permissible backup fuse | B6 B10 B16 |
Digital Control (configurable)
| Designation | Remote |
| Low signal | Connection to SGnd with < 2.7 kΩ |
| High signal | Open (> 35 kΩ between Remote and SGnd) |
Digital Control Low-Active (configurable)
| Battery-operated start 230 V AC low signal | Connection to SGnd with < 2.7 kΩ |
| Battery-operated start 230 V AC high signal | Open (> 200 kΩ between Bat.-Start and SGnd) |
Output data
| Classification according to IEC 62040-3 | VFD-SS-311 |
| Efficiency | > 95 % (100% load, with charged battery) |
| Efficiency | ~ 81 % (100 % load ) |
| Nominal Output Voltage | 230 V AC |
| Form of output voltage | Pure sine |
| Nominal output current (IN) | 3 A |
| Bridging time | 60 s |
| UPS connection in parallel | no |
| UPS connection in series | no |
| Apparent power | 750 VA |
| Nominal power | 600 W (Real power) |
| Crest factor | 2.8 |
| Switch-over time | < 10 ms |
| Connection in parallel | no |
| Connection in series | No |
Mains operation
| Nominal Output Voltage | 230 V AC |
| Nominal output current (IN) | 3 A (750 VA) |
Battery operation
| Nominal Output Voltage | 230 V AC |
| Nominal output current (IN) | 3 A (750 VA) |
| Frequency (after automatic detection in mains operation) | 50 Hz |
| Frequency (after automatic detection in mains operation) | 60 Hz |
Signal: Alarm
| Output Voltage | 24 V (SELV) |
| Continuous load current | ≤ 20 mA |
Signal: Battery mode
| Output Voltage | 24 V (SELV) |
| Continuous load current | ≤ 20 mA |
Signal: Ready
| Output Voltage | 24 V (SELV) |
| Continuous load current | ≤ 20 mA |
Signal:
| Signal ground SGnd | Reference potential for Bat.-Mode, Ready, Remote, and Bat.-Start |
Energy storage
| Nominal voltage UN | 24 V DC |
| Charging current | 0.7 A ... 1.1 A |
| Nominal capacity | 4 Ah |
| Nominal capacity range | 4 Ah |
| Charging time | 7 h |
| Buffer period | 20 min. (100 W) |
| Buffer period | 4 min. (300 W) |
| Buffer period | 1 min. (600 W) |
| Latest startup date (battery only) | 6 Months (0 °C ... 20 °C) |
| Latest startup (battery only) - range | 6 Months ... 3 Months (20 °C ... 30 °C) |
| Latest startup (battery only) - range | 3 Months ... 1 Months (30 °C ... 40 °C) |
| Battery technology | Lead rechargeable battery module |
| Memory medium | Lead rechargeable battery module |
| Accumulator type | 2x Panasonic UP-VW1220P1 / BB Battery HR4.2-12FR |
| Can be extended with external battery | 1x 24 V 4 Ah |
| Battery fuse | 40 A, 32 V |
Input
| Connection Method | Push-in connection |
| Conductor cross section, rigid min. | 0.2 mm² |
| Conductor cross section, rigid max. | 4 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 10 mm |
Output
| Connection Method | Push-in connection |
| Conductor cross section, rigid min. | 0.2 mm² |
| Conductor cross section, rigid max. | 4 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 10 mm |
Signal
| Connection Method | Push-in connection |
| Conductor cross section, rigid min. | 0.2 mm² |
| Conductor cross section, rigid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
Interfaces
| Interface | MINI-USB type B |
| Maximum cable length | 3 m |
Signaling
| Types of signaling | LED |
Signal output: Transistor output, active
| Signalization designation | Alarm |
| Status display | LED |
| Color | red |
| Signalization designation | Battery mode |
| Status display | LED |
| Color | yellow |
| Signalization designation | Ready |
Signal output
| Status display | LED |
| Color | green |
| Signalization designation | Battery charge |
| Status display | LED |
| Color | yellow |
| Signalization designation | Service |
| Status display | LED |
| Color | red |
Electrical properties
| Number of phases | 1.00 |
Product properties
| Product family | TRIO AC UPS – UPS with integrated battery |
| MTBF (IEC 61709, SN 29500) | > 206000 h (40 °C) |
Insulation characteristics
| Protection class | I |
| Overvoltage category | III |
| Degree of pollution | 2 |
Life expectancy (electrolytic capacitors)
| Time | 32000 h |
Dimensions
| Width | 210 mm |
| Height | 170 mm |
| Depth | 136 mm |
Installation dimensions
| Installation distance right/left | 0 mm / 0 mm |
| Installation distance top/bottom | 50 mm / 50 mm |
Mounting
| Mounting Type | DIN rail mounting |
Material specifications
| Type of housing | DX51D+AZ (steel sheet / Galvalume) |
| Hood version | PC + ABS |
Ambient conditions
| Degree of Protection | IP20 |
| Ambient Temperature (Operation) | 0 °C ... 40 °C |
| Ambient temperature (storage/transport) | -15 °C ... 40 °C (with charged energy storage device) |
| Maximum altitude | ≤ 3000 m (> 2000 m, observe derating) |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Max. permissible relative humidity (operation) | ≤ 95 % (25 °C, non-condensing) |
| Shock | 20g in all directions (EN 60068-2-27) |
| Shock | 30g in each space direction with UWA 130 |
| Vibration (Operation) | 5 Hz ... 100 Hz, 0.7g (EN 60068-2-6) |
Standards
| Standard uninterruptible power supply systems | EN 62040-1 |
EMC data
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
| Interference emission | Noise emission in accordance with EN 62040-2 |
| Noise immunity | Immunity in accordance with EN 62040-2 |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Conducted noise emission | EN 62040-02 (Class C2) |
Electrostatic discharge
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | 6 kV (Test Level 3) |
| Discharge in air | 8 kV (Test Level 3) |
| Comments | Criterion A |
Electromagnetic HF field
| Standards/regulations | EN 61000-4-3 |
| Frequency Range | 80 MHz ... 3 GHz |
| Test field strength | 10 V/m |
| Comments | Criterion A |
Fast transients (burst)
| Standards/regulations | EN 61000-4-4 |
| Input | 2 kV (Test Level 3 - asymmetrical) |
| Input | 2 kV (Test Level 3 - asymmetrical) |
| Output | 2 kV (Test Level 3 - asymmetrical) |
| Signal | 2 kV (Test Level 3 - asymmetrical) |
| Signal | 2 kV (Test Level 3 - asymmetrical) |
| Comments | Criterion A (B for USB) |
Surge voltage load (surge)
| Standards/regulations | EN 61000-4-5 |
| Input | 1 kV (Test Level 2 - symmetrical) |
| Input | 2 kV (Test Level 3 - asymmetrical) |
| Output | 1 kV (Test Level 2 - symmetrical) |
| Output | 2 kV (Test Level 3 - asymmetrical) |
| Signal | 1 kV (Test Level 2 - asymmetrical) |
| Comments | Criterion B |
Conducted interference
| Standards/regulations | EN 61000-4-6 |
| Frequency Range | 0.15 MHz ... 80 MHz |
| Comments | Criterion A |
| Voltage | 10 V |
Power frequency magnetic field
| Standards/regulations | EN 61000-4-8 |
| Frequency | 50 Hz |
| Test field strength | 100 A/m |
| Comments | Criterion A |
Emitted interference
| Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Criteria
| Criterion A | Normal operating behavior within the specified limits. |
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Accessories
Why Proax for Phoenix Contact 2905909?
Proax is an authorized distributor of Phoenix Contact 2905909 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended
TRIO-PS/1AC/12DC/10, TRIO POWER power supplies with standard functionalityTRIO POWER is particularly suited to standard machine production, thanks to 1- and 3-phase versions up to 960 W. The wide-range input and the international approval package enable worldwide use.The robust metal housing, the high electric strength, and the wide temperature range ensure a high level of power supply reliability.
TRIO-PS/1AC/5DC/10, TRIO POWER power supplies with standard functionalityTRIO POWER is particularly suited to standard machine production, thanks to 1- and 3-phase versions up to 960 W. The wide-range input and the international approval package enable worldwide use.The robust metal housing, the high electric strength, and the wide temperature range ensure a high level of power supply reliability.