QUINT4-ORING/12-24DC/2X20/2X20 - Redundancy module

Active redundancy module QUINT ORING with decoupling MOSFET, ACB Technology, DIN rail mounting, 12 V DC ... 24 V DC, 2x 20 A, 2x 20 A

  • Service life of the redundant solution is doubled, thanks to uniform distribution of the load
  • Save energy
  • Permanent monitoring of redundancy
  • Consistent redundancy up to the load
Technical Specifications

Input data

Nominal input voltage range12 V DC ... 24 V DC
Input voltage range8 V DC ... 29.5 V DC
Voltage type of supply voltageDC
Nominal input current (IN)2x 20 A
Static Boost (IStat.Boost)2x 25 A
Dynamic Boost (IDyn.Boost)2x 30 A (5 s)
Selective Fuse Breaking (ISFB)2x 120 A (15 ms)
Reverse polarity protection< yes60 V DC
Intended listed circuit breaker for input protection60 V DC
Intended listed circuit breaker for input protection16 A (Characteristic B, C)
Voltage drop, input/outputtyp. 0.1 V (IOUT = 20 A)

Output data

Efficiencytyp. 98.5 % (12 V DC)
Efficiencytyp. 99 % (24 V DC)
Nominal Output VoltageUIn - 0.1 V
Nominal output current (IN)2x 20 A
Nominal output current (IN)1x 40 A
Static Boost (IStat.Boost)2x 25 A
Static Boost (IStat.Boost)1x 50 A
Dynamic Boost (IDyn.Boost)2x 30 A (5 s)
Dynamic Boost (IDyn.Boost)1x 60 A (5 s)
Selective Fuse Breaking (ISFB)2x 120 A (15 ms)
Selective Fuse Breaking (ISFB)1x 240 A (15 ms)
Connection in seriesNo
Feedback voltage resistance≤ 32 V DC
Protection against overvoltage at the output (OVP)≤ 32 V DC
Power loss nominal load max.4.08 W (IOUT = 40 A)
Power loss nominal load max.12.7 W (IOUT = 40 A)

Signal relay 13/14

Connection labeling3.1, 3.2
Switch contact (floating)floating
Maximum contact load30 V DC
Maximum contact load100 mA
Signal optionRedundancy OK

Signal relay 23/24

Connection labeling3.3, 3.4
Switch contact (floating)floating
Maximum contact load30 V DC
Maximum contact load100 mA
Signal optionACB OK

Input

Position1.x

Conductor connection

Connection MethodScrew connection
rigid0.2 mm² ... 6 mm²
flexible0.2 mm² ... 4 mm²
flexible with ferrule without plastic sleeve0.25 mm² ... 4 mm²
flexible with ferrule with plastic sleeve0.25 mm² ... 4 mm²
rigid (AWG)24 ... 10
Stripping length8 mm
Tightening torque0.5 Nm ... 0.6 Nm
Drive form screw headSlotted L

Output

Position2.x

Conductor connection

Connection MethodScrew connection
rigid0.5 mm² ... 16 mm²
flexible0.5 mm² ... 16 mm²
flexible with ferrule without plastic sleeve0.5 mm² ... 16 mm²
flexible with ferrule with plastic sleeve0.5 mm² ... 16 mm²
rigid (AWG)20 ... 6
Stripping length10 mm
Tightening torque1.2 Nm ... 1.6 Nm
Drive form screw headSlotted L

Signal

Position3.x

Conductor connection

Connection MethodPush-in connection
rigid0.2 mm² ... 1 mm²
flexible0.2 mm² ... 1.5 mm²
flexible with ferrule without plastic sleeve0.2 mm² ... 1.5 mm²
flexible with ferrule with plastic sleeve0.2 mm² ... 0.75 mm²
rigid (AWG)24 ... 16
Stripping length8 mm

LED signaling

Types of signalingDC OK (green)
Signal thresholdRedundancy OK (LED lights up green)
Signal thresholdI < In (LED lights up green)
Signal thresholdACB OK (LED lights up green)
Signal thresholdACB OK (sources are slightly asymmetrical) (LED lights up green and yellow)
Signal thresholdSources are asymmetrical (LED flashing red)

Electrical properties

Insulation voltage input, output / housing600 V AC
Insulation voltage input, output / housing850 V DC

Product properties

Product familyQUINT ORING
MTBF (IEC 61709, SN 29500)> 1792000 h (25 °C)
MTBF (IEC 61709, SN 29500)> 1007000 h (40 °C)
MTBF (IEC 61709, SN 29500)> 460000 h (60 °C)
Environmental protection directiveRoHS Directive 2011/65/EU
Environmental protection directiveWEEE
Environmental protection directiveReach
LEDyes

Insulation characteristics

Protection classIII
Degree of pollution2

Life expectancy (electrolytic capacitors)

Current40 A
Temperature40 °C
Time224000 h
Additional text12 V DC
Current40 A
Temperature40 °C
Time182000 h
Additional text24 V DC

Item dimensions

Width46 mm
Height130 mm
Depth132 mm
Depth125 mm (Device depth (DIN rail mounting))

Item dimensions with alternative mounting

Width122 mm
Height130 mm
Depth49 mm

Installation dimensions

Installation distance right/left5 mm / 5 mm
Installation distance top/bottom50 mm / 50 mm

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsalignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
Mounting Positionhorizontal DIN rail NS 35, EN 60715

Material specifications

Flammability rating according to UL 94 (housing / terminal blocks)V0
Housing MaterialMetal
Type of housingAluminum (AlMg3)
Hood versionGalvanized sheet steel, free from chrome (VI)
Side element versionAluminum

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude5000 m
Max. permissible relative humidity (operation)≤ 100 % (at 25 °C, non-condensing)
Shock (operation)18 ms, 30g, per spatial direction (IEC 60068-2-27)
Vibration (Operation)< 15 Hz, amplitude ±2.5 mm (IEC 60068-2-6)
Vibration (Operation)15 Hz ... 150 Hz, 2.3g, 90 min.

Electrical safety

Standard designationElectrical safety (of control and regulation devices)
Standards/specificationsIEC 61010-1

Protective extra-low voltage

Standard designationProtective extra-low voltage
Standards/specificationsEN 61010-1 (SELV)
Standard designationProtective extra-low voltage
Standards/specificationsIEC 61010-2-201 (PELV)

Shipbuilding

IdentificationDNV

UL

IdentificationUL Listed UL 61010-1
IdentificationUL Listed UL 61010-2-201
IdentificationUL 121201 & CSA C22.2 No. 213-17 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)

CSA

IdentificationCAN/CSA-C22.2 No. 61010-1-12
IdentificationCAN/CSA C22.2 No. 61010-2-201:18

ATEX

Identification II 3 G Ex ec nC IIC T4 Gc
IdentificationDEKRA 22ATEX0104 X

IECEx

IdentificationEx ec nC IIC T4 Gc
IdentificationIECEx DEK 22.0089X

UKEX

Identification II 3 G Ex ec nC IIC T4 Gc
IdentificationDEKRA 22UKEX6029X

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emissionEN 61000-6-3
EMC requirements for noise emissionEN 61000-6-4
EMC requirements for noise immunityEN 61000-6-1
EMC requirements for noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Conducted noise emissionEN 55016
Conducted noise emissionEN 61000-6-3 (Class B)
Noise emissionAdditional basic standard EN 61000-6-5 (immunity in power station)
Noise emissionEN 55016
Noise emissionEN 61000-6-3 (Class B)
DNV GL conducted interferenceClass B
Additional textBridge and deck area
DNV GL noise radiationClass B
Additional textBridge and deck area

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge6 kV (Test Level 3)
Discharge in air8 kV (Test Level 3)
CommentsCriterion B

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 1 GHz
Test field strength20 V/m (Test Level 3)
Frequency Range1 GHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input2 kV (Test Level 3 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
Signal2 kV (Test Level 4 - asymmetrical)
CommentsCriterion A

Surge voltage load (surge)

Standards/regulationsEN 61000-4-5
Input0.5 kV (Test Level 2 - symmetrical)
Input1 kV (Test Level 2 - asymmetrical)
Output0.5 kV (Test Level 2 - symmetrical)
Output1 kV (Test Level 2 - asymmetrical)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
I/O/Sasymmetrical
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

Why Proax for Phoenix Contact 1088207?

Proax is an authorized distributor of Phoenix Contact 1088207 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability