MACX MCR-EX-1TS-I-OLP - Temperature measuring transducer
Ex i-Output loop-powered temperature transducer for transmitting RTD and TC sensor signals as well as from resistance and voltage sensors via 4 mA ... 20 mA. HART, Ex i signal conditioners, Standard configuration, Screw connection
Technical Specifications
Product properties
Product family | MACX Analog |
No. of channels | 1 |
Type | Ex i signal conditioners |
Configuration | Software |
Configuration | HART |
Insulation characteristics
Overvoltage category | II |
Pollution degree | 2 |
Electrical properties
Step response (0–99%) | 1 s (TC) |
Step response (0–99%) | 1 s (RTD) |
Electrical isolation Input/output
Test voltage | 2 kV AC (50 Hz, 60 s) |
Supply
Supply Voltage Range | loop-powered, no external supply necessary |
Supply Voltage Range | 11 V DC ... 30 V DC |
Signal
Input Signal | Temperature |
Measurement
Number of Inputs | 1 |
Input voltage range | -20 mV ... 100 mV (Minimum measuring span: 5 mV) |
Sensor types (RTD) that can be used | Pt, Ni, Cu sensors: 2, 3, 4-wire |
Sensor types that can be used (TC) | A, B, C, D, E, J, K, L, N, R, S, T, U |
Temperature measuring range | -250 °C ... 2500 °C (Range depending on the sensor type) |
Temperature measuring range | ≥ 10 K (RTD) |
Temperature measuring range | ≥ 50 K (TC) |
Linear resistance measuring range | 10 Ω ... 2000 Ω (Minimum measuring span: 10 Ω) |
Signal: Current
Current Output Signal | 4 mA ... 20 mA |
Current Output Signal | 20 mA ... 4 mA |
Max. current output signal | 23 mA |
Load | (UL - 11 V) / 0,023 A |
HART coding | FSK ± 0.5 mA |
HART version | 7 |
Transmission Speed | 1200 Baud |
Mains frequency filter | 50/60 Hz |
Communication resistance | ≥ 250 Ω |
Switch-on delay | 7 s (HART) |
Switch-on delay | 7 s (Measured value) |
Connection data
Connection Method | Screw connection |
Stripping length | 7 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Tightening torque | 0.5 Nm ... 0.6 Nm |
Test socket
Max. diameter | 2 mm |
Ex data
Ex installation (EPL) | Gb |
Ex installation (EPL) | Div. 1 |
Data communication (bypass)
Protocols Supported | HART |
Signaling
Status display | LED red |
Dimensions
Width | 12.5 mm |
Height | 112.5 mm |
Depth | 113.7 mm |
Depth NS 35/7,5 | 114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715) |
Material specifications
Color | gray (RAL 7042) |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -40 °C ... 85 °C |
Ambient temperature (storage/transport) | -50 °C ... 100 °C |
Altitude | ≤ 4000 m (Above sea level) |
Climatic class | B2 |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
CE
Certificate | CE-compliant |
ATEX
Identification | II 2 (1) G Ex ib [ia Ga] IIC T6...T4 Gb |
Certificate | EPS 20 ATEX 1 166 X |
IECEx
Identification | Ex ib [ia Ga] IIC T6...T4 Gb |
Certificate | IECEx EPS 20.0060X |
CSA
Identification | IS for Class I, Div. 2, Groups A, B, C, D; T6...T4 |
Identification | AIS / Class I / Div. 1 / ABCD |
Mounting
Mounting Type | DIN rail mounting |
Accessories
Why Proax for Phoenix Contact 1145365?
Proax is an authorized distributor of Phoenix Contact 1145365 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- MACX MCR-EX-IDS-I-I-SP - Ex i output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA … 20 mA signals with intrinsic safety to a load in the Ex area. 3-way electrical isolation, line fault detection (can be switched off via DIP switch), SIL 2 (SC3) in accordance with IEC 61508, Push-in connection.