MACX MCR-EX-1TS-I-OLP - Temperature measuring transducer
Ex i-Output loop-powered temperature transducer for transmitting RTD and TC sensor signals as well as from resistance and voltage sensors via 4 mA ... 20 mA. HART, Ex i signal conditioners, Standard configuration, Screw connection
Technical Specifications
Product properties
| Product family | MACX Analog |
| No. of channels | 1 |
| Type | Ex i signal conditioners |
| Configuration | Software |
| Configuration | HART |
Insulation characteristics
| Overvoltage category | II |
| Pollution degree | 2 |
Electrical properties
| Step response (0–99%) | 1 s (TC) |
| Step response (0–99%) | 1 s (RTD) |
Electrical isolation Input/output
| Test voltage | 2 kV AC (50 Hz, 60 s) |
Supply
| Supply Voltage Range | loop-powered, no external supply necessary |
| Supply Voltage Range | 11 V DC ... 30 V DC |
Signal
| Input Signal | Temperature |
Measurement
| Number of Inputs | 1 |
| Input voltage range | -20 mV ... 100 mV (Minimum measuring span: 5 mV) |
| Sensor types (RTD) that can be used | Pt, Ni, Cu sensors: 2, 3, 4-wire |
| Sensor types that can be used (TC) | A, B, C, D, E, J, K, L, N, R, S, T, U |
| Temperature measuring range | -250 °C ... 2500 °C (Range depending on the sensor type) |
| Temperature measuring range | ≥ 10 K (RTD) |
| Temperature measuring range | ≥ 50 K (TC) |
| Linear resistance measuring range | 10 Ω ... 2000 Ω (Minimum measuring span: 10 Ω) |
Signal: Current
| Current Output Signal | 4 mA ... 20 mA |
| Current Output Signal | 20 mA ... 4 mA |
| Max. current output signal | 23 mA |
| Load | (UL - 11 V) / 0,023 A |
| HART coding | FSK ± 0.5 mA |
| HART version | 7 |
| Transmission Speed | 1200 Baud |
| Mains frequency filter | 50/60 Hz |
| Communication resistance | ≥ 250 Ω |
| Switch-on delay | 7 s (HART) |
| Switch-on delay | 7 s (Measured value) |
Connection data
| Connection Method | Screw connection |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 14 |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
Test socket
| Max. diameter | 2 mm |
Ex data
| Ex installation (EPL) | Gb |
| Ex installation (EPL) | Div. 1 |
Data communication (bypass)
| Protocols Supported | HART |
Signaling
| Status display | LED red |
Dimensions
| Width | 12.5 mm |
| Height | 112.5 mm |
| Depth | 113.7 mm |
| Depth NS 35/7,5 | 114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715) |
Material specifications
| Color | gray (RAL 7042) |
Ambient conditions
| Degree of Protection | IP20 |
| Ambient Temperature (Operation) | -40 °C ... 85 °C |
| Ambient temperature (storage/transport) | -50 °C ... 100 °C |
| Altitude | ≤ 4000 m (Above sea level) |
| Climatic class | B2 |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
CE
| Certificate | CE-compliant |
ATEX
| Identification | II 2 (1) G Ex ib [ia Ga] IIC T6...T4 Gb |
| Certificate | EPS 20 ATEX 1 166 X |
IECEx
| Identification | Ex ib [ia Ga] IIC T6...T4 Gb |
| Certificate | IECEx EPS 20.0060X |
CSA
| Identification | IS for Class I, Div. 2, Groups A, B, C, D; T6...T4 |
| Identification | AIS / Class I / Div. 1 / ABCD |
Mounting
| Mounting Type | DIN rail mounting |
Accessories
Why Proax for Phoenix Contact 1145365?
Proax is an authorized distributor of Phoenix Contact 1145365 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended
MACX MCR-EX-IDS-I-I-SP - Ex i output signal conditioner, HART-transparent. Isolates and transmits 0/4 mA … 20 mA signals with intrinsic safety to a load in the Ex area. 3-way electrical isolation, line fault detection (can be switched off via DIP switch), SIL 2 (SC3) in accordance with IEC 61508, Push-in connection.