3047617
UT 4-FE - Feed-through terminal block
Feed-through terminal block, nom. voltage: 1000 V, nominal current: 32 A, number of connections: 2, number of positions: 1, connection method: Screw connection, cross section: 0.14 mm2 - 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: black/yellow
UT
The Phoenix Contact UT Series comprises feed-through terminal blocks that utilize screw connection technology, offering reliable and maintenance-free conductor connections for various industrial applications. These terminal blocks are designed to accommodate a wide range of conductor cross-sections, providing flexibility and ease of installation.
Key Features:
- ✅ Screw Connection Technology: The UT Series employs a screw connection method, ensuring secure and durable connections. The Reakdyn principle, a screw locking technique developed by Phoenix Contact, prevents loosening of terminal block screws, eliminating the need for retightening.
- ✅ Versatile Conductor Accommodation: These terminal blocks can connect solid and stranded conductors without ferrules, even above the nominal cross-section, due to their large wiring space. This feature allows for universal application across various conductor types and sizes.
- ✅ Compact Design: The UT Series offers a compact, space-saving design, making it ideal for smaller control cabinets and boxes where space is at a premium.
Product properties
| Number of Positions | 1 | 
| Number of Connections | 2 | 
| Number of rows | 1 | 
Insulation characteristics
| Overvoltage category | III | 
| Degree of pollution | 3 | 
Electrical properties
| Rated surge voltage | 8 kV | 
| Maximum power dissipation for nominal condition | 1.02 W | 
Connection data
| Number of connections per level | 2 | 
| Nominal cross section | 4 mm² | 
| Rated cross section AWG | 10 | 
| Screw thread | M3 | 
| Tightening torque | 0.6 ... 0.8 Nm | 
| Stripping length | 9 mm | 
| Internal cylindrical gage | A4 | 
| Connection in acc. with standard | IEC 60947-7-1 | 
| Conductor cross section rigid | 0.14 mm² ... 6 mm² | 
| Cross section AWG | 26 ... 10 (converted acc. to IEC) | 
| Conductor cross section flexible | 0.14 mm² ... 6 mm² | 
| Conductor cross section, flexible [AWG] | 26 ... 10 (converted acc. to IEC) | 
| Conductor cross-section flexible (ferrule without plastic sleeve) | 0.25 mm² ... 4 mm² | 
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.25 mm² ... 4 mm² | 
| 2 conductors with same cross section, solid | 0.14 mm² ... 1.5 mm² | 
| 2 conductors with same cross section, flexible | 0.14 mm² ... 1.5 mm² | 
| 2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² | 
| 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² ... 2.5 mm² | 
| Nominal Current | 32 A (with 4 mm² conductor cross section) | 
| Maximum Load Current | 41 A (with 6 mm² conductor cross section) | 
| Nominal Voltage | 1000 V | 
| Note | Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area. | 
Rated data (ATEX/IECEx)
| Identification |  II 2 GD Ex eb IIC Gb | 
| Operating temperature range | -60 °C ... 110 °C | 
| Ex-certified accessories | 3047028 D-UT 2,5/10 | 
| Ex-certified accessories | 3047167 ATP-UT | 
| Ex-certified accessories | 1205053 SZS 0,6X3,5 | 
| Ex-certified accessories | 3022276 CLIPFIX 35-5 | 
| Ex-certified accessories | 3022218 CLIPFIX 35 | 
| List of bridges | Plug-in bridge / FBS 2-6 / 3030336 | 
| List of bridges | Plug-in bridge / FBS 3-6 / 3030242 | 
| List of bridges | Plug-in bridge / FBS 4-6 / 3030255 | 
| List of bridges | Plug-in bridge / FBS 5-6 / 3030349 | 
| List of bridges | Plug-in bridge / FBS 10-6 / 3030271 | 
| List of bridges | Plug-in bridge / FBS 20-6 / 3030365 | 
| List of bridges | Plug-in bridge / FBS 50-6 / 3032224 | 
| Bridge data | 27 A / 4 mm² | 
| Ex temperature increase | 40 K (33.3 A / 4 mm²) | 
| Rated voltage | 690 V | 
| for bridging with bridge | 690 V | 
| - At bridging between non-adjacent terminal blocks | 352 V | 
| - At bridging between non-adjacent terminal blocks via PE terminal block | 275 V | 
| - At cut-to-length bridging with cover | 220 V | 
| - At cut-to-length bridging with partition plate | 275 V | 
| Rated Insulation Voltage | 630 V | 
| Output | (Permanent) | 
Ex level General
| Rated current | 30 A | 
| Maximum Load Current | 38 A | 
| Contact resistance | 0.26 mΩ | 
Ex connection data General
| Torque range | 0.6 Nm ... 0.8 Nm | 
| Nominal cross section | 4 mm² | 
| Rated cross section AWG | 12 | 
| Connection capacity rigid | 0.14 mm² ... 6 mm² | 
| Connection capacity AWG | 26 ... 10 | 
| Connection capacity flexible | 0.14 mm² ... 4 mm² | 
| Connection capacity AWG | 26 ... 12 | 
| 2 conductors with same cross section, solid | 0.14 mm² ... 1.5 mm² | 
| 2 conductors with the same cross-section AWG rigid | 26 ... 16 | 
| 2 conductors with same cross section, stranded | 0.14 mm² ... 1.5 mm² | 
| 2 conductors with the same cross-section AWG flexible | 26 ... 16 | 
Dimensions
| Width | 6.2 mm | 
| End cover width | 2.2 mm | 
| Height | 46.9 mm | 
| Depth on NS 35/7,5 | 47.5 mm | 
| Depth on NS 35/15 | 55 mm | 
Material specifications
| Color | black/yellow | 
| Flammability rating according to UL 94 | V0 | 
| Insulating material group | I | 
| Insulating material | PA | 
| Static insulating material application in cold | -60 °C | 
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C | 
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 | 
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 | 
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 | 
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 | 
| Surface flammability NFPA 130 (ASTM E 162) | passed | 
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed | 
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed | 
Surge voltage test
| Test voltage setpoint | 9.8 kV | 
| Result | Test passed | 
Temperature-rise test
| Requirement temperature-rise test | Increase in temperature ≤ 45 K | 
| Result | Test passed | 
| Short-time withstand current 4 mm² | 0.48 kA | 
| Short-time withstand current 6 mm² | 0.72 kA | 
| Result | Test passed | 
Power-frequency withstand voltage
| Test voltage setpoint | 2.2 kV | 
| Result | Test passed | 
Mechanical data
| Open side panel | Yes | 
Mechanical strength
| Result | Test passed | 
Attachment on the carrier
| DIN rail/fixing support | NS 35 | 
| Test force setpoint | 1 N | 
| Result | Test passed | 
Test for conductor damage and slackening
| Rotation speed | 10 rpm | 
| Revolutions | 135 | 
| Conductor cross section/weight | 0.14 mm² / 0.2 kg | 
| Conductor cross section/weight | 4 mm² / 0.9 kg | 
| Conductor cross section/weight | 6 mm² / 1.4 kg | 
| Result | Test passed | 
Needle-flame test
| Time of exposure | 30 s | 
| Result | Test passed | 
Oscillation/broadband noise
| Specification | DIN EN 50155 (VDE 0115-200):2008-03 | 
| Spectrum | Service life test category 1, class B, body mounted | 
| Frequency | f1 = 5 Hz to f2 = 150 Hz | 
| ASD level | 1.857 (m/s²)²/Hz | 
| Acceleration | 0.8g | 
| Test duration per axis | 5 h | 
| Test directions | X-, Y- and Z-axis | 
| Result | Test passed | 
Shocks
| Specification | DIN EN 50155 (VDE 0115-200):2008-03 | 
| Pulse shape | Half-sine | 
| Acceleration | 5g | 
| Shock duration | 30 ms | 
| Number of shocks per direction | 3 | 
| Test directions | X-, Y- and Z-axis (pos. and neg.) | 
| Result | Test passed | 
Ambient conditions
| Ambient Temperature (Operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) | 
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) | 
| Ambient temperature (assembly) | -5 °C ... 70 °C | 
| Ambient temperature (actuation) | -5 °C ... 70 °C | 
| Permissible humidity (operation) | 20 % ... 90 % | 
| Permissible humidity (storage/transport) | 30 % ... 70 % | 
Standards and Regulations
| Connection in acc. with standard | IEC 60947-7-1 | 
Mounting
| Mounting Type | NS 35/7,5 | 
| Mounting Type | NS 35/15 | 
Why Proax for Phoenix Contact 3047617?
Proax is an authorized distributor of Phoenix Contact 3047617 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
| Pack Size | 50 | 
 UT 4-HESILED 60 (5X20) - Fuse modular terminal block, fuse type: Glass / ceramics / ..., fuse type: G / 5 x 20, nom. voltage: 60 V, nominal current: 6.3 A, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2- 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: black UT 4-HESILED 60 (5X20) - Fuse modular terminal block, fuse type: Glass / ceramics / ..., fuse type: G / 5 x 20, nom. voltage: 60 V, nominal current: 6.3 A, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2- 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: black
 UT 4-HESILED 24-P/P - Fuse modular terminal block, With test socket screws for insertion of test plugs, fuse type: Glass / ceramics / ..., fuse type: G / 5 x 20, nom. voltage: 24 V, nominal current: 6.3 A, number of positions: 1, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2- 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: black UT 4-HESILED 24-P/P - Fuse modular terminal block, With test socket screws for insertion of test plugs, fuse type: Glass / ceramics / ..., fuse type: G / 5 x 20, nom. voltage: 24 V, nominal current: 6.3 A, number of positions: 1, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2- 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: black
 UT 4-HESILED 24 (5X20) - Fuse modular terminal block, fuse type: Glass / ceramics / ..., fuse type: G / 5 x 20, nom. voltage: 24 V, nominal current: 6.3 A, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2- 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: black UT 4-HESILED 24 (5X20) - Fuse modular terminal block, fuse type: Glass / ceramics / ..., fuse type: G / 5 x 20, nom. voltage: 24 V, nominal current: 6.3 A, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2- 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: black
 UT 4-HESILED 24 (5X20) 820KOHM - Fuse modular terminal block, fuse type: Glass / ceramics / ..., fuse type: G / 5 x 20, nom. voltage: 24 V, nominal current: 6.3 A, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2- 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: black UT 4-HESILED 24 (5X20) 820KOHM - Fuse modular terminal block, fuse type: Glass / ceramics / ..., fuse type: G / 5 x 20, nom. voltage: 24 V, nominal current: 6.3 A, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2- 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: black
 UT 4-HESILED 24 (5X20) BU - Fuse modular terminal block, fuse type: Glass / ceramics / ..., fuse type: G / 5 x 20, nom. voltage: 24 V, nominal current: 6.3 A, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2- 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: blue UT 4-HESILED 24 (5X20) BU - Fuse modular terminal block, fuse type: Glass / ceramics / ..., fuse type: G / 5 x 20, nom. voltage: 24 V, nominal current: 6.3 A, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2- 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: blue
 UT 4-HESILED 24 (5X20) GY - Fuse modular terminal block, fuse type: Glass / ceramics / ..., fuse type: G / 5 x 20, nom. voltage: 24 V, nominal current: 6.3 A, number of positions: 1, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2- 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: gray UT 4-HESILED 24 (5X20) GY - Fuse modular terminal block, fuse type: Glass / ceramics / ..., fuse type: G / 5 x 20, nom. voltage: 24 V, nominal current: 6.3 A, number of positions: 1, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2- 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: gray
 UT 4-HESILA 250 (5X20) - Fuse modular terminal block, fuse type: Glass / ceramics / ..., fuse type: G / 5 x 20, nom. voltage: 250 V, nominal current: 6.3 A, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2- 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: black UT 4-HESILA 250 (5X20) - Fuse modular terminal block, fuse type: Glass / ceramics / ..., fuse type: G / 5 x 20, nom. voltage: 250 V, nominal current: 6.3 A, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2- 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: black
 UT 4-CB - Feed-through terminal block, With breakout partition plate in the bridge shaft, nom. voltage: 1000 V, nominal current: 32 A, number of connections: 2, number of positions: 1, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2 - 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: gray UT 4-CB - Feed-through terminal block, With breakout partition plate in the bridge shaft, nom. voltage: 1000 V, nominal current: 32 A, number of connections: 2, number of positions: 1, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2 - 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: gray
 UT 4-CB BN - Feed-through terminal block, With breakout partition plate in the bridge shaft, nom. voltage: 1000 V, nominal current: 32 A, number of connections: 2, number of positions: 1, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2 - 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: brown UT 4-CB BN - Feed-through terminal block, With breakout partition plate in the bridge shaft, nom. voltage: 1000 V, nominal current: 32 A, number of connections: 2, number of positions: 1, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2 - 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: brown