Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
PSR-SCP-42-230UC/URM4/4X1/2X2B
Weight
0.239 kg
This product has been discontinued and replaced with 2702924
Series PSR-SCP

PSR-SCP-42-230UC/URM4/4X1/2X2B - Extension module

1- or 2-channel contact extension with wide range input, 4 N/O contacts, 1 N/C contact, 1 confirmation current path, together with basic device up to Cat. 4, PL e in accordance with EN ISO 13849, plug-in screw terminal block, width: 22.5 mm

Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties

Product familyPSRclassic
ApplicationExtension module
Mechanical service life10x 10⁶ cycles
Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3

Electrical properties

Maximum power dissipation for nominal condition1.8 W
Nominal operating mode100% operating factor

Air clearances and creepage distances between the power circuits

Rated Insulation Voltage250 V AC
Rated surge voltage/insulationBasic insulation 4 kV:between all current paths and housingSafe isolation, reinforced insulation 6 kV:between A1/A2 and 13/14, 23/24, 33/34, 43/44between 51/52, 61/62 and 13/14, 23/24, 33/34, 43/44between A1/A2 and 51/52, 61/62

General

Power consumption at UStyp. 1.68 W (42 V DC)
Power consumption at UStyp. 4.6 W (230 V AC)
Control supply voltage range42 V AC/DC ... 230 V AC/DC -15 % ... +10 % (Rated control circuit supply voltage US)
Rated control supply current IS40 mA (42 V DC)
Rated control supply current IS20 mA (230 V AC)
Inrush Current15 A (Δt = 100 μs at Us)
Typ. starting time with Us< 55 ms (when controlled via A1)
Typical release time< 20 ms (Control via A1 at 42 V DC)
Typical release time< 30 ms (Control via A1 at 48 V DC)
Typical release time< 40 ms (Control via A1 at 60 V DC)
Typical release time< 60 ms (Control via A1 at 110 V AC)
Typical release time< 150 ms (Control via A1 at 230 V AC)
Recovery time< 1 s
Maximum switching frequency0.5 Hz
Protective circuitSurge protection; Suppressor diode and varistors
Operating voltage display1 x green LED

Output data

Contact switching type4 enabling current paths
Contact switching type1 confirmation current path
Contact switching type1 signaling current path
Contact MaterialAgSnO2
Maximum Switching Voltage250 V AC/DC (Observe the load curve)
Minimum Switching Voltage5 V AC/DC
Limiting Continuous Current6 A (N/O contact, pay attention to the derating)
Limiting Continuous Current6 A (N/C contact)
Maximum Inrush Current8 A
Inrush current, minimum10 mA
Sq. Total current36 A2 (observe derating)
Interrupting rating (ohmic load) max.144 W (24 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.288 W (48 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.180 W (60 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.77 W (110 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.88 W (220 V DC, τ = 0 ms)
Interrupting rating (ohmic load) max.1500 VA (250 V AC, τ = 0 ms)
Maximum interrupting rating (inductive load)42 W (24 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)40 W (48 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)36 W (60 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)35 W (110 V DC, τ = 40 ms)
Maximum interrupting rating (inductive load)33 W (220 V DC, τ = 40 ms)
Switching capacity min.50 mW
Switching capacity (360/h cycles)4 A (24 V DC)
Switching capacity (360/h cycles)4 A (230 V AC)
Switching capacity (3600/h cycles)2.5 A (24 V (DC13))
Switching capacity (3600/h cycles)3 A (230 V (AC15))
Output fuse10 A gL/gG (N/O contact)
Output fuse6 A gL/gG (N/C contact)

Connection technology

pluggableyes

Conductor connection

Connection MethodScrew connection
Conductor cross section, rigid0.2 mm² ... 2.5 mm²
Conductor cross section, flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Stripping length7 mm
Screw threadM3

Dimensions

Width22.5 mm
Height99 mm
Depth114.5 mm

Material specifications

Coloryellow
Housing MaterialPolyamide

Safety data

Stop category0

Safety data: EN ISO 13849

Category4 (In conjunction with suitable evaluating device)
Performance level (PL)e (In conjunction with suitable evaluating device)

Safety data: EN 50156

Safety Integrity Level (SIL)3

Safety data: IEC 61508 - High demand

Safety Integrity Level (SIL)3 (In conjunction with suitable evaluating device)

Safety data: IEC 61508 - Low demand

Safety Integrity Level (SIL)3 (In conjunction with suitable evaluating device)

Safety data: EN IEC 62061

Safety Integrity Level (SIL)3 (In conjunction with suitable evaluating device)

Ambient conditions

Degree of ProtectionIP20
Min. degree of protection of inst. locationIP54
Ambient Temperature (Operation)-20 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Shock15g
Vibration (Operation)10 Hz ... 150 Hz, 2g

CE

CertificateCE-compliant

Air clearances and creepage distances between the power circuits

Standards/regulationsDIN EN 50178/VDE 0160

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsSee derating curve
Mounting Positionvertical or horizontal

Why Proax for Phoenix Contact 2902935?

Proax is an authorized distributor of Phoenix Contact 2902935 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability