Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
PSR-SCP-230AC/ESAM2/3X1/1X2/B
Weight
0.239 kg
Series PSR-SCP

PSR-SCP-230AC/ESAM2/3X1/1X2/B - Safety relays

Safety relay for emergency stop and safety door up to SIL 1, Cat. 1, PL c, depending on the application up to SIL 3, Cat. 4, PL e, single-channel operation, 3 enabling current paths, nominal input voltage of 230 V AC/DC, plug-in screw terminal blocks

  • Up to Cat. 1/PL c in accordance with ISO 13849-1, SIL 1 in accordance with EN IEC 62061, SIL 1 in accordance with IEC 61508
  • Depending on the application, up to Cat. 4/PL e in accordance with ISO 13849-1, SIL 3 in accordance with EN IEC 62061, SIL 3 in accordance with IEC 61508
  • 1-channel control
  • Basic insulation
Technical Specifications

Product properties

Product familyPSRclassic
ApplicationEmergency stop
ApplicationSafety door
Mechanical service lifeapprox. 10⁷ cycles
Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3

Electrical properties

Maximum power dissipation for nominal condition2.88 W
Nominal operating mode100% operating factor

Air clearances and creepage distances between the power circuits

Rated Insulation Voltage250 V AC
Rated surge voltage/insulation4 kV / basic insulation (safe isolation, reinforced insulation, and 6 kV between A1-A2/logic/enabling and signaling current paths)

General

Rated control circuit supply voltage US230 V AC -15 % / +10 %
Rated control supply current IS22 mA
Voltage at input/start and feedback circuit~ 24 V DC
Typical response time50 ms (manual start)
Typical response time300 ms (automatic start)
Typ. starting time with Us300 ms (when controlled via A1 or S11/S12)
Typical release time20 ms (when controlled via S11/S12)
Typical release time150 ms (when controlled via A1)
Recovery time1 s
Maximum switching frequency0.5 Hz
Protective circuitSurge protection; Suppressor diode
Protective circuitSurge protection; Varistor
Max. permissible overall conductor resistance50 Ω

Output data

Contact switching type3 enabling current paths
Contact switching type1 signaling current path
Contact MaterialAgSnO2, gold-flashed
Maximum Switching Voltage250 V AC/DC
Minimum Switching Voltage10 V AC/DC
Limiting Continuous Current6 A (Enabling current paths)
Limiting Continuous Current5 A (Signaling current path)
Maximum Inrush Current6 A
Inrush current, minimum10 mA
Sq. Total current72 A2 (ITH2 = I12 + I22 + I32)
Interrupting rating (ohmic load) max.144 W (at 24 V DC)
Interrupting rating (ohmic load) max.230 W (at 48 V DC)
Interrupting rating (ohmic load) max.68 W (at 110 V DC)
Interrupting rating (ohmic load) max.88 W (at 220 V DC)
Interrupting rating (ohmic load) max.2000 VA (for 250 V AC)
Maximum interrupting rating (inductive load)48 W (at 24 V DC)
Maximum interrupting rating (inductive load)40 W (at 48 V DC)
Maximum interrupting rating (inductive load)35 W (at 110 V DC)
Maximum interrupting rating (inductive load)33 W (at 220 V DC)
Switching capacity min.100 mW
Switching capacity (360/h cycles)6 A (24 V DC)
Switching capacity (360/h cycles)5 A (230 V AC)
Switching capacity (3600/h cycles)3 A (24 V (DC13))
Switching capacity (3600/h cycles)3 A (230 V (AC 15))
Output fuse10 A gL/gG NEOZED (Enabling current paths)
Output fuse6 A gL/gG NEOZED (Signaling current paths)

Connection technology

pluggableyes

Conductor connection

Connection MethodScrew connection
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross-section AWG24 ... 12
Stripping length7 mm
Screw threadM3

Signaling

Status display2 x green LEDs
Operating voltage display1 x green LED

Dimensions

Width22.5 mm
Height99 mm
Depth114.5 mm

Material specifications

Housing MaterialPolyamide

Safety data

Stop category0

Safety data: EN ISO 13849

Category1 (up to Cat. 4 depending on the application)
Performance level (PL)c (up to PL e depending on the application)

Safety data

Safety Integrity Level (SIL)1 (up to SIL 3 depending on the application)
Safety Integrity Level (SIL)1 (up to SIL 3 depending on the application)
Safety Integrity Level (SIL)1 (up to SIL 3 depending on the application)

Ambient conditions

Degree of ProtectionIP20
Min. degree of protection of inst. locationIP54
Ambient Temperature (Operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Shock15g
Vibration (Operation)10 Hz ... 150 Hz, 2g

Conformity/Approvals

ConformanceCE-compliant

Air clearances and creepage distances between the power circuits

Standards/regulationsIEC 60664-1

Mounting

Mounting TypeDIN rail mounting
Mounting Positionany

Why Proax for Phoenix Contact 2901430?

Proax is an authorized distributor of Phoenix Contact 2901430 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability