Series VAL-CP-MCB
VAL-CP-MCB-1S-350/40/FM - Type 2 surge arrester
Combination of type 2 surge protection and arrester backup fuse, with monitoring of arrester and arrester backup fuse, in combination with a remote indication contact. Design: 3-conductor system (L1, N, PE), mounting on NS 35 DIN rail
- Combinations of type 2 arresters with integrated arrester backup fuse
- Signaling to monitoring systems via remote indication contact in the event of an error
- Overload of the surge protection results in all-pos. disconnection from the mains
- Type 2 consistent plug-in surge arresters
- Optical, mechanical status indication for the individual arresters
Technical Specifications
Product properties
| Product family | SEC Family |
| IEC test classification | II |
| IEC test classification | T2 |
| EN type | T2 |
| IEC power supply system | TN-S |
| IEC power supply system | TT |
| Type | DIN rail module, two-section, divisible |
| Number of Positions | 2 |
| Surge protection fault message | Optical, remote indicator contact |
Insulation characteristics
| Overvoltage category | III |
| Pollution degree | 2 |
Electrical properties
| Nominal frequency fN | 50 Hz (60 Hz) |
Indicator/remote signaling
| Connection name | Remote fault indicator contact |
| Switching function | Changeover contact |
| Operating Voltage | 250 V AC |
| Operating Voltage | 250 V DC |
| Operating current | 1 mA AC ... 2 A AC |
| Operating current | 1 mA DC ... 50 mA DC |
Connection protective circuit
| Connection Method | Screw connection |
| Tightening torque | 3.5 Nm |
| Stripping length | 14 mm |
| Conductor cross section flexible | 4 mm² ... 25 mm² |
| Conductor cross section rigid | 4 mm² ... 35 mm² |
| Conductor cross section AWG | 18 ... 2 |
Protective ground connection
| Connection Method | Screw connection |
| Screw thread | M5 |
| Tightening torque | 4.5 Nm |
| Stripping length | 16 mm |
| Conductor cross section flexible | 2.5 mm² ... 16 mm² |
| Conductor cross section rigid | 2.5 mm² ... 25 mm² |
| Conductor cross section AWG | 12 ... 4 |
Remote fault indicator contact
| Connection Method | Pluggable screw connection |
| Screw thread | M2 |
| Tightening torque | 0.25 Nm |
| Stripping length | 7 mm |
| Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
| Conductor cross section rigid | 0.14 mm² ... 1.5 mm² |
| Conductor cross section AWG | 28 ... 16 |
Dimensions
| Width | 72 mm |
| Height | 101 mm |
| Depth | 76 mm |
| Horizontal pitch | 4 Div. |
Material specifications
| Color | light grey (RAL 7035) |
| Color | black (RAL 9005) |
| Flammability rating according to UL 94 | V-0 |
| CTI value of material | 600 |
| Insulating material | PBT-FR |
| Material group | I |
| Housing Material | PBT-FR |
Protective circuit
| Mode of protection | L-N |
| Mode of protection | L-PE |
| Mode of protection | N-PE |
| Direction of action | 1L-N & N-PE |
| Nominal voltage UN | 240 V AC (TN-S) |
| Nominal voltage UN | 240 V AC (TT) |
| Nominal frequency fN | 50 Hz (60 Hz) |
| Maximum continuous operating voltage UC (L-N) | 350 V AC |
| Maximum continuous operating voltage UC (L-PE) | 350 V AC |
| Maximum continuous operating voltage UC (N-PE) | 264 V AC |
| Residual current IPE | ≤ 1 µA |
| Nominal discharge current In (8/20) µs (L-N) | 15 kA |
| Nominal discharge current In (8/20) µs (L-PE) | 15 kA |
| Nominal discharge current In (8/20) µs (N-PE) | 20 kA |
| Maximum discharge current Imax (8/20) µs | 30 kA |
| Follow current interrupt rating Ifi (N-PE) | 100 A |
| Short-circuit current rating ISCCR | 25 kA |
| Voltage protection level Up (L-N) | ≤ 2.5 kV |
| Voltage protection level Up (N-PE) | ≤ 1.7 kV |
| Residual voltage Ures (L-N) | ≤ 2.3 kV (at In) |
| Residual voltage Ures (L-N) | ≤ 1.6 kV (at 10 kA) |
| Residual voltage Ures (L-N) | ≤ 1.3 kV (at 5 kA) |
| Residual voltage Ures (L-N) | ≤ 1 kV (at 3 kA) |
| Residual voltage Ures (L-PE) | ≤ 2.5 kV (at In) |
| Residual voltage Ures (L-PE) | ≤ 2 kV (at 10 kA) |
| Residual voltage Ures (L-PE) | ≤ 1.5 kV (at 5 kA) |
| Residual voltage Ures (L-PE) | ≤ 1.1 kV (at 3 kA) |
| Residual voltage Ures (N-PE) | ≤ 1.2 kV (at 10 kA) |
| Residual voltage Ures (N-PE) | ≤ 0.8 kV (at 5 kA) |
| Residual voltage Ures (N-PE) | ≤ 0.5 kV (at 4 kA) |
| Residual voltage Ures (N-PE) | ≤ 0.3 kV (at 3 kA) |
| TOV behavior at UT (L-N) | 415 V AC (5 s / withstand mode) |
| TOV behavior at UT (L-N) | 457 V AC (120 min / safe failure mode) |
| TOV behavior at UT (N-PE) | 1200 V AC (200 ms / withstand mode) |
| Response time tA (L-N) | ≤ 25 ns |
| Response time tA (L-PE) | ≤ 100 ns |
| Response time tA (N-PE) | ≤ 100 ns |
| Max. backup fuse with V-type through wiring | 40 A (gG) |
Ambient conditions
| Degree of Protection | IP20 |
| Ambient Temperature (Operation) | -25 °C ... 60 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m (amsl) |
| Permissible humidity (operation) | 5 % ... 95 % |
Standards and Regulations
| Standards/specifications | IEC 61643-11 |
| Note | 2011 |
| Standards/specifications | EN 61643-11 |
| Note | 2012 |
| Standards/specifications | IEC 60364-4-443 |
| Standards/specifications | IEC 60364-5-534 |
Mounting
| Mounting Type | DIN rail: 35 mm |
Why Proax for Phoenix Contact 2882763?
Proax is an authorized distributor of Phoenix Contact 2882763 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended