2804403
SKU
PHX2804403
MPN
VAL-CP-MOSO 60-3S-FM
Weight
1.375 kg
Series VAL-CP-MOSO
VAL-CP-MOSO 60-3S-FM - Type 2 surge arrester
Combination of type 2 surge protection and arrester backup fuse, with arrester monitoring, in combination with a status indicator and remote indication contact. Design: 5-conductor system (L1, L2, L3, N, PE), mounting on 60 mm system technology (power rail system)
- Tool-free mounting on 5 and 10 mm busbars
- Disconnect device on each individual plug
- Excellent level of information provided by visual status indicator and remote indication contact
- Type 2 consistent plug-in surge arresters
Technical Specifications
Product properties
| IEC test classification | II |
| IEC test classification | T2 |
| EN type | T2 |
| IEC power supply system | TN-S |
| IEC power supply system | TT |
| Type | Module for 60 mm system technology |
| Number of Positions | 4 |
| Surge protection fault message | Optical, remote indicator contact |
Insulation characteristics
| Overvoltage category | III |
| Pollution degree | 2 |
Electrical properties
| Nominal frequency fN | 50 Hz (60 Hz) |
| Nominal voltage UN | 240 V AC (230/400 V AC ... 240/415 V AC) |
Indicator/remote signaling
| Connection name | Remote fault indicator contact |
| Switching function | Changeover contact |
| Operating Voltage | 5 V AC ... 250 V AC |
| Operating Voltage | 125 V DC (200 mA DC) |
| Operating current | 5 mA AC ... 1 A AC |
| Operating current | 1 A DC (30 V DC) |
PE conductor connection
| Connection Method | Screw connection |
| Screw thread | M5 |
| Tightening torque | 4.5 Nm |
| Stripping length | 16 mm |
| Conductor cross section flexible | 2.5 mm² ... 16 mm² |
| Conductor cross section rigid | 2.5 mm² ... 25 mm² |
| Conductor cross section AWG | 12 ... 4 |
N conductor connection
| Connection Method | Screw connection |
| Screw thread | M5 |
| Tightening torque | 4.5 Nm |
| Stripping length | 16 mm |
| Conductor cross section flexible | 2.5 mm² ... 16 mm² |
| Conductor cross section rigid | 2.5 mm² ... 25 mm² |
| Conductor cross section AWG | 12 ... 4 |
Phase conductor connection
| Connection Method | 60 mm power rail system |
Remote fault indicator contact
| Connection Method | Pluggable screw connection |
| Screw thread | M2 |
| Tightening torque | 0.25 Nm |
| Stripping length | 7 mm |
| Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
| Conductor cross section rigid | 0.14 mm² ... 1.5 mm² |
| Conductor cross section AWG | 28 ... 16 |
Dimensions
| Width | 54 mm |
| Height | 220 mm |
| Depth | 134 mm |
Material specifications
| Color | light grey (RAL 7035) |
| Flammability rating according to UL 94 | V-0 |
| CTI value of material | 600 |
| Insulating material | PBT, PA6, PA66 |
| Material group | I |
| Housing Material | PBT |
| Housing Material | PA 6 |
| Housing Material | PA 6.6 |
Protective circuit
| Mode of protection | L-N |
| Mode of protection | L-PE |
| Mode of protection | N-PE |
| Direction of action | 3L-N & N-PE |
| Nominal voltage UN | 240/415 V AC (TN-S) |
| Nominal voltage UN | 240/415 V AC (TT) |
| Nominal frequency fN | 50 Hz (60 Hz) |
| Maximum continuous operating voltage UC (L-N) | 350 V AC |
| Maximum continuous operating voltage UC (L-PE) | 350 V AC |
| Maximum continuous operating voltage UC (N-PE) | 264 V AC |
| Residual current IPE | ≤ 1 µA |
| Nominal discharge current In (8/20) µs | 20 kA |
| Maximum discharge current Imax (8/20) µs (L-N) | 25 kA |
| Maximum discharge current Imax (8/20) µs (L-PE) | 25 kA |
| Maximum discharge current Imax (8/20) µs (N-PE) | 40 kA |
| Follow current interrupt rating Ifi (N-PE) | 100 A (264 V AC) |
| Short-circuit current rating ISCCR | 25 kA |
| Voltage protection level Up (L-N) | ≤ 2.5 kV |
| Voltage protection level Up (N-PE) | ≤ 1.5 kV |
| Residual voltage Ures (L-N) | ≤ 2.1 kV (at In) |
| Residual voltage Ures (L-N) | ≤ 1.9 kV (at 10 kA) |
| Residual voltage Ures (L-N) | ≤ 1.8 kV (at 5 kA) |
| Residual voltage Ures (L-N) | ≤ 1.7 kV (at 3 kA) |
| Residual voltage Ures (L-PE) | ≤ 2.3 kV (at In) |
| Residual voltage Ures (L-PE) | ≤ 2 kV (at 10 kA) |
| Residual voltage Ures (L-PE) | ≤ 1.9 kV (at 5 kA) |
| Residual voltage Ures (L-PE) | ≤ 1.8 kV (at 3 kA) |
| Residual voltage Ures (N-PE) | ≤ 0.5 kV (at In) |
| Residual voltage Ures (N-PE) | ≤ 0.5 kV (at 10 kA) |
| Residual voltage Ures (N-PE) | ≤ 0.5 kV (at 5 kA) |
| Residual voltage Ures (N-PE) | ≤ 0.5 kV (at 3 kA) |
| TOV behavior at UT (L-N) | 415 V AC (5 s / withstand mode) |
| TOV behavior at UT (L-N) | 440 V AC (120 min / safe failure mode) |
| TOV behavior at UT (N-PE) | 1200 V AC (200 ms / withstand mode) |
| Response time tA (L-N) | ≤ 25 ns |
| Response time tA (L-PE) | ≤ 100 ns |
| Response time tA (N-PE) | ≤ 100 ns |
| Max. backup fuse with branch wiring | not required |
Ambient conditions
| Degree of Protection | IP20 |
| Ambient Temperature (Operation) | -25 °C ... 55 °C |
| Ambient temperature (storage/transport) | -40 °C ... 75 °C |
| Altitude | ≤ 2000 m (amsl) |
| Permissible humidity (operation) | 5 % ... 95 % |
Air clearances and creepage distances
| Standards/regulations | DIN VDE 0110-1 / IEC 60664-1 / IEC 61643-11 |
| Standards/specifications | IEC 61643-11 |
| Note | 2011 |
| Standards/specifications | EN 61643-11 |
| Note | 2012 |
Mounting
| Mounting Type | 60 mm system technology (power rail) |
Accessories
Why Proax for Phoenix Contact 2804403?
Proax is an authorized distributor of Phoenix Contact 2804403 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended