VAL-CP-2S-175 - Type 2 surge arrester

Plug-in surge arrester for 2-phase power supply networks with separate N and PE (4-conductor system: L1, L2, N, PE), with remote indication contact.

Technical Specifications

Product properties

IEC test classificationII
IEC test classificationT2
EN typeT2
IEC power supply systemTN-S
IEC power supply systemTT
TypeDIN rail module, two-section, divisible
Number of Positions3
Surge protection fault messageOptical, remote indicator contact

Insulation characteristics

Overvoltage categoryIII
Pollution degree2

Electrical properties

Nominal frequency fN50 Hz (60 Hz)
Nominal voltage UN120 V AC

Indicator/remote signaling

Connection nameRemote fault indicator contact
Switching functionChangeover contact
Operating Voltage5 V AC ... 250 V AC
Operating Voltage125 V DC (200 mA DC)
Operating current5 mA AC ... 1 A AC
Operating current1 A DC (30 V DC)

Connection data

Connection MethodScrew connection
Screw threadM5
Tightening torque4.5 Nm
Stripping length16 mm
Conductor cross section flexible2.5 mm² ... 16 mm²
Conductor cross section rigid2.5 mm² ... 25 mm²
Conductor cross section AWG12 ... 4

Remote fault indicator contact

Connection MethodPluggable screw connection
Screw threadM2
Tightening torque0.25 Nm
Stripping length7 mm
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Conductor cross section rigid0.14 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16

Dimensions

Width37.25 mm
Height98 mm
Depth71.5 mm
Horizontal pitch2 Div.

Material specifications

Flammability rating according to UL 94V-0
CTI value of material600
Insulating materialPBT-FR
Material groupI
Housing MaterialPBT-FR

Protective circuit

Mode of protectionL-N
Mode of protectionL-PE
Mode of protectionN-PE
Direction of action2L-N & N-PE
Nominal voltage UN120/208 V AC (TN-S)
Nominal voltage UN120/208 V AC (TT)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous operating voltage UC (L-N)175 V AC
Maximum continuous operating voltage UC (L-PE)175 V AC
Maximum continuous operating voltage UC (N-PE)150 V AC
Rated load current IL40 A (Biconnect M4 fork-type cable lug 6​ mm²)
Rated load current IL63 A (TWIN ferrule 2 x 10 mm²)
Residual current IPE≤ 1 µA
Nominal discharge current In (8/20) µs (L-N)20 kA
Nominal discharge current In (8/20) µs (N-PE)20 kA
Maximum discharge current Imax (8/20) µs (L-N)40 kA
Maximum discharge current Imax (8/20) µs (N-PE)40 kA
Follow current interrupt rating Ifi (N-PE)100 A (150 V AC)
Short-circuit current rating ISCCR25 kA
Voltage protection level Up (L-N)≤ 0.85 kV
Voltage protection level Up (L-PE)≤ 1.3 kV
Voltage protection level Up (N-PE)≤ 0.95 kV
Residual voltage Ures (L-N)≤ 0.85 kV (at In)
Residual voltage Ures (L-N)≤ 0.75 kV (at 10 kA)
Residual voltage Ures (L-N)≤ 0.65 kV (at 5 kA)
Residual voltage Ures (L-N)≤ 0.63 kV (at 4 kA)
Residual voltage Ures (L-N)≤ 0.57 kV (at 2 kA)
Residual voltage Ures (N-PE)≤ 0.4 kV (at In)
Residual voltage Ures (N-PE)≤ 0.4 kV (at 10 kA)
Residual voltage Ures (N-PE)≤ 0.4 kV (at 5 kA)
Residual voltage Ures (N-PE)≤ 0.4 kV (at 4 kA)
Residual voltage Ures (N-PE)≤ 0.4 kV (at 2 kA)
TOV behavior at UT (L-N)240 V AC (5 s / withstand mode)
TOV behavior at UT (L-N)240 V AC (120 min / safe failure mode)
TOV behavior at UT (N-PE)1200 V AC (200 ms / withstand mode)
Response time tA (L-N)≤ 25 ns
Response time tA (N-PE)≤ 100 ns
Max. backup fuse with V-type through wiring40 A (gG / Biconnect M4 fork-type cable lug, 6​ mm²)
Max. backup fuse with V-type through wiring63 A (gG / TWIN ferrule 2x 10mm²)
Max. backup fuse with branch wiring315 A (gG)

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl)
Permissible humidity (operation)5 % ... 95 %
Shock (operation)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (Operation)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)

UL specifications

Maximum continuous operating voltage MCOV (L-L)350 V AC
Maximum continuous operating voltage MCOV (L-N)175 V AC
Maximum continuous operating voltage MCOV (L-G)175 V AC
Maximum continuous operating voltage MCOV (N-G)150 V AC
Nominal discharge current In (L-L)20 kA
Nominal discharge current In (L-N)20 kA
Nominal discharge current In (L-G)20 kA
Nominal discharge current In (N-G)20 kA
Mode of protectionL-L
Mode of protectionL-N
Mode of protectionL-G
Mode of protectionN-G
Nominal Voltage120/208 V AC
Power distribution systemWye
Nominal frequency50/60 Hz
Measured limiting voltage MLV (L-L)2010 V
Measured limiting voltage MLV (L-N)1510 V
Measured limiting voltage MLV (L-G)1630 V
Measured limiting voltage MLV (N-G)560 V
Follow current (L-G)200 A (150 V AC)
SPD Type4CA

UL indicator/remote signaling

Operating Voltage125 V AC
AC operating current1 A AC

UL connection data

Tightening torque40 lbf-in. ... 50 lbf-in.
Conductor cross section AWG14 ... 2 (solid)
Conductor cross section AWG14 ... 4 (flexible)

Air clearances and creepage distances

Standards/regulationsDIN VDE 0110-1 / IEC 60664-1 / IEC 61643-11 / UL 1449
Standards/specificationsIEC 61643-11
Note2011
Standards/specificationsEN 61643-11
Note2012

Mounting

Mounting TypeDIN rail: 35 mm

Why Proax for Phoenix Contact 2859495?

Proax is an authorized distributor of Phoenix Contact 2859495 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size1
Recommended

Price N/A

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability