Official Distributor
SKU
MPN
PLC-RPT- 24UC/2X21/FG
Weight
0.078 kg
This product is Not Cancellable/Not Returnable
Series PLC-RPT
PLC-RPT- 24UC/2X21/FG - Relay Module
PLC-INTERFACE, consisting of a relay base and plug-in safety relay with force-guided contacts in accordance with DIN EN 61810-3, Push-in connection, 2 changeover contacts, forcibly actuated, Bridge rectifier, Input voltage: 24 V AC/DC
Technical Specifications
Product properties
Product family | PLC-INTERFACE |
Application | Forcibly guided contacts |
Operating mode | 100% operating factor |
Mechanical service life | approx. 107 cycles |
B10d | 600000 Cycles (AC1; 250 V / 6 A; 1 NO) |
B10d | 900000 Cycles (AC1; 250 V / 3 A; 1 NO) |
B10d | 1800000 Cycles (AC1; 250 V / 1,5 A; 1 NO) |
B10d | 180000 Cycles (AC15; 250 V / 3 A; 1 NO) |
B10d | 560000 Cycles (AC15; 250 V / 2 A; 1 NO) |
B10d | 4600000 Cycles (AC15; 250 V / 0,75 A; 1 NO) |
B10d | 360000 Cycles (DC13; 24 V / 3 A; 1 NO) |
B10d | 740000 Cycles (DC13; 24 V / 1,5 A; 1 NO) |
B10d | 4200000 Cycles (DC13; 24 V / 0,75 A; 1 NO) |
Insulation characteristics
Insulation | Safe isolation, reinforced insulation |
Insulation characteristics: Standards/regulations
Insulation | Safe isolation, reinforced insulation |
Overvoltage category | III |
Pollution degree | 2 |
Electrical properties
Maximum power dissipation for nominal condition | 0.72 W |
Test voltage (Winding/contact) | 4 kVrms (50 Hz, 1 min., winding/contact) |
Test voltage (Changeover contact/changeover contact) | 2.5 kVrms (50 Hz, 1 min., changeover contact/changeover contact) |
Standards/regulations
Rated Insulation Voltage | 250 V AC |
Rated surge voltage | 6 kV |
Coil side
Nominal input voltage UN | 24 V AC/DC |
Input voltage range | 20.9 V DC ... 32.4 V DC (20 °C) |
Input voltage range in reference to UN | see diagram |
Drive and function | monostable |
Drive (polarity) | polarized |
Typical input current at UN | 30 mA |
Typical response time | 3 ms ... 15 ms |
Typical release time range | 3 ms ... 15 ms |
Coil Voltage | 24 V DC |
Protective circuit | Bridge rectifier |
Operating voltage display | Yellow LED |
Switching
Contact switching type | 2 changeover contacts, forcibly actuated |
Type of switch contact | Single contact |
Contact Material | AgNi |
Maximum Switching Voltage | 250 V AC/DC |
Minimum Switching Voltage | 5 V (10 mA) |
Limiting Continuous Current | 6 A |
Maximum Inrush Current | 6 A |
Min. switching current | 10 mA (5 V) |
Interrupting rating (ohmic load) max. | 144 W (24 V DC) |
Interrupting rating (ohmic load) max. | 288 W (48 V DC) |
Interrupting rating (ohmic load) max. | 88 W (110 V DC) |
Interrupting rating (ohmic load) max. | 110 W (220 V DC) |
Interrupting rating (ohmic load) max. | 1500 VA (250 V AC) |
Switching capacity min. | 150 mW |
Switching capacity | 3 A (24 V, DC13) |
Switching capacity | 3 A (230 V, AC15) |
Force-guided contacts in accordance with EN 61810-3 | Type B |
Connection data
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² (Single ferrule) |
Conductor cross section flexible | 2x 0.5 mm² ... 1 mm² (TWIN ferrule) |
Conductor cross section AWG | 26 ... 14 |
Dimensions
Width | 14 mm |
Height | 80 mm |
Depth | 104 mm |
Material specifications
Color | gray (RAL 7042) |
Ambient conditions
Degree of protection (Relay) | RT II (Relay) |
Degree of protection (Relay base) | IP20 (Relay base) |
Degree of protection (Installation location) | ≥ IP54 (Installation location) |
Ambient Temperature (Operation) | -20 °C ... 60 °C |
Ambient temperature (storage/transport) | -20 °C ... 85 °C |
Altitude | ≤ 2000 m |
CE
Certificate | CE-compliant |
UKCA
Certificate | UKCA-compliant |
UL, USA
Identification | UL 508 |
Identification | UL 508 Recognized |
UL, USA/Canada
Identification | UL 508 |
Identification | UL 508 Recognized |
Shipbuilding approval
Certificate | TAE0000196 |
Corrosive gas test
Identification | ISA-S71.04. G3 Harsh Group |
Identification | EN 60068-2-60 |
DNV GL data
Temperature | D |
Humidity | A |
Vibration | B/C |
EMC | B |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive |
Electromagnetic compatibility | Conformance with EMC directive |
Standards/regulations
Standards/regulations | IEC 60947-5-1 |
Standards/regulations | DIN EN 61810-3 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | in rows with zero spacing |
Mounting Position | any |
Accessories
Why Proax for Phoenix Contact 2910539?
Proax is an authorized distributor of Phoenix Contact 2910539 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 10 |
Recommended