PLC-RPT- 24UC/21/RW - Relay Module

PLC-INTERFACE for railway applications, consisting of basic terminal block with Push-in connection and plug-in miniature relay with power contact, range: 0.7 x UN to 1.25 x UN, temperature class TX: -40°C to +70°C, 1 changeover contact, input voltage 24 V DC

  • Optimum relay operation thanks to wide-range electronics
  • Certified in accordance with EN 50155
  • Vibration and shock resistance in accordance with EN 50155
  • Safe isolation between coil and contact side
  • Temperature range: -40 °C ... + 70 °C (short-term 85 °C)
  • Input voltage range of 0.7 to 1.25 x UN (1.4 x UN briefly)
Technical Specifications

Product properties

Product familyPLC-INTERFACE
ApplicationRailway applications
Installation locationAttached to the vehicle body
Operating mode100% operating factor
Mechanical service lifeapprox. 2x 107 cycles

Insulation characteristics

Overvoltage categoryIII
Pollution degree2

Electrical properties

Maximum power dissipation for nominal condition0.22 W
Test voltage (Winding/contact)4 kVrms (50 Hz, 1 min., winding/contact)
Rated Insulation Voltage250 V AC
Rated surge voltage6 kV

Coil side

Nominal input voltage UN24 V DC
Input voltage range18.5 V DC ... 33.6 V DC
Input voltage range in reference to UN0.7 ... 1.25
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN9 mA
Typical response time4 ms
Typical release time4 ms
Coil Voltage12 V DC
Protective circuitSurge protection; Freewheeling diode
Protective circuitRCZ filter
Protective circuitWide-range electronics
Operating voltage displayYellow LED

Switching

Contact switching type1 changeover contact
Type of switch contactSingle contact
Contact MaterialAgSnO
Maximum Switching Voltage250 V AC/DC (Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules.)
Minimum Switching Voltage5 V (100 mA)
Limiting Continuous Current6 A
Maximum Inrush Current10 A (4 s)
Min. switching current10 mA (12 V)
Short-circuit current200 A (conditional short-circuit current)
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
Interrupting rating (ohmic load) max.20 W (at 48 V DC)
Interrupting rating (ohmic load) max.18 W (at 60 V DC)
Interrupting rating (ohmic load) max.23 W (at 110 V DC)
Interrupting rating (ohmic load) max.40 W (at 220 V DC)
Interrupting rating (ohmic load) max.1500 VA (for 250 V AC)
Output fuse4 A gL/gG NEOZED
Switching capacity1 A (at 24 V, DC13)
Switching capacity0.2 A (at 110 V, DC13)
Switching capacity0.1 A (at 220 V, DC13)
Switching capacity3 A (at 24 V, AC15)
Switching capacity3 A (at 120 V, AC15)
Switching capacity3 A (at 230 V, AC15)

Connection data

Connection MethodPush-in connection
Stripping length10 mm
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm² (Single ferrule)
Conductor cross section flexible2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG26 ... 14

Dimensions

Width6.2 mm
Height80 mm
Depth94 mm

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)

Ambient conditions

Degree of protection (Relay)RT III (Relay)
Degree of protection (Relay base)IP20 (Relay base)
Ambient Temperature (Operation)-40 °C ... 70 °C (Temperature class TX)
Ambient temperature (storage/transport)-40 °C ... 85 °C

CE

CertificateCE-compliant

UKCA

CertificateUKCA-compliant

Shipbuilding approval

CertificateTAE0000196

Corrosive gas test

IdentificationISA-S71.04. G3 Harsh Group
IdentificationEN 60068-2-60

DNV GL data

TemperatureD
HumidityA
VibrationB/C
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive
Electromagnetic compatibilityConformance with EMC directive

Standards and Regulations

Standards/regulationsIEC 60947-5-1
Standards/regulationsEN 50155 (VDE 0115 part 200)
Standards/regulationsEN 61373
Standards/regulationsEN 50121

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsin rows with zero spacing
Mounting Positionany
Accessories

Why Proax for Phoenix Contact PLC-RPT- 24UC/21/RW?

Proax is an authorized distributor of Phoenix Contact PLC-RPT- 24UC/21/RW and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesPLCRPT24UC21RW
Pack Size10
Recommended
Sold in quantities of 10

Available for order