Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
PLC-RSC-230UC/21-21AU/MS
Weight
0.08 kg
Series PLC-RSC

PLC-RSC-230UC/21-21AU/MS - Relay Module

PLC-INTERFACE, consisting of a relay base and pluggable multilayer gold contact relay with manual operation, integrated status LED, Screw connection, 2 changeover contacts, Bridge rectifier, Input voltage: 230 V AC / 220 V DC

Technical Specifications

Product properties

Product familyPLC-INTERFACE
ApplicationPalm switch
Operating mode100% operating factor
Mechanical service life5x 106 cycles

Insulation characteristics

InsulationSafe isolation, reinforced insulation

Insulation characteristics: Standards/regulations

InsulationSafe isolation, reinforced insulation
Overvoltage categoryIII
Pollution degree2

Electrical properties

Maximum power dissipation for nominal condition1.15 W
Test voltage (Winding/contact)4 kVrms (50 Hz, 1 min., winding/contact)
Test voltage (Changeover contact/changeover contact)2.5 kVrms (50 Hz, 1 min., changeover contact/changeover contact)

Standards/regulations

Rated Insulation Voltage250 V AC
Rated surge voltage6 kV

Coil side

Nominal input voltage UN230 V AC
Nominal input voltage UN220 V DC
Input voltage range207 V AC ... 264.5 V AC (20 °C)
Input voltage range209 V DC ... 264 V DC (20 °C)
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN5 mA
Typical response time6 ms (220 V DC)
Typical response time3 ms ... 15 ms (230 V AC)
Typical release time10 ms (220 V DC)
Typical release time range3 ms ... 15 ms (230 V AC)
Protective circuitBridge rectifier; Bridge rectifier
Operating voltage displayYellow LED

Switching

Contact switching type2 changeover contacts
Type of switch contactSingle contact
Contact MaterialAgNi, hard gold-plated
Maximum Switching Voltage30 V AC
Maximum Switching Voltage36 V DC
Minimum Switching Voltage12 V (1 mA)
Limiting Continuous Current50 mA
Maximum Inrush Current50 mA
Min. switching current1 mA (12 V)

Switching: when the gold layer is destroyed

Notethe following values are applicable if a gold layer is destroyed
Maximum Switching Voltage250 V AC/DC
Minimum Switching Voltage12 V (10 mA)
Limiting Continuous Current6 A
Maximum Inrush Current12 A (20 ms)
Min. switching current10 mA (12 V)
Interrupting rating (ohmic load) max.192 W (24 V DC)
Interrupting rating (ohmic load) max.62 W (48 V DC)
Interrupting rating (ohmic load) max.42 W (60 V DC)
Interrupting rating (ohmic load) max.55 W (110 V DC)
Interrupting rating (ohmic load) max.66 W (220 V DC)
Interrupting rating (ohmic load) max.2000 VA (250 V AC)
Switching capacity1 A (24 V, DC13)
Switching capacity1.5 A (230 V, AC15)

Connection data

Connection MethodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm² (Single ferrule)
Conductor cross section flexible2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG26 ... 14
Tightening torque0.6 Nm ... 0.8 Nm

Dimensions

Width14 mm
Height80 mm
Depth104 mm

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)

Ambient conditions

Degree of protection (Relay)RT II (Relay)
Degree of protection (Relay base)IP20 (Relay base)
Degree of protection (Installation location)≥ IP54 (Installation location)
Ambient Temperature (Operation)-20 °C ... 50 °C
Ambient temperature (storage/transport)-20 °C ... 85 °C
Altitude≤ 2000 m

CE

CertificateCE-compliant

UKCA

CertificateUKCA-compliant

UL, USA

IdentificationUL 508
IdentificationUL 508 Recognized

UL, USA/Canada

IdentificationUL 508
IdentificationUL 508 Recognized

Shipbuilding approval

CertificateTAE0000196

Corrosive gas test

IdentificationISA-S71.04. G3 Harsh Group
IdentificationEN 60068-2-60

DNV GL data

TemperatureD
HumidityA
VibrationB/C
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive
Electromagnetic compatibilityConformance with EMC directive

Standards/regulations

Standards/regulationsEN 50178

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsin rows with zero spacing
Mounting Positionany
Accessories

Why Proax for Phoenix Contact 2910513?

Proax is an authorized distributor of Phoenix Contact 2910513 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size10
Recommended
Sold in quantities of 10

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability