Series PLC-RSC

PLC-RSC-230UC/21HC/SO46 - Relay Module

PLC-INTERFACE for protection against interference currents/voltages on the control side. Consisting of PLC-BSC-230UC/21HC/SO46 basic terminal block with screw connection and plug-in miniature relay with power contact up to 10 A, 1 changeover contact, 230 V AC input voltage

Technical Specifications

Notes

Notes on operationThe PLC-ATP partition plate must be installed for voltages greater than 250 V (L1, L2, L3) between identical terminal blocks on adjacent modules.
Notes on operationThe PLC-ATP separating plate should be installed for safe isolation between adjacent modules
Notes on operationThe system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact.
Assembly instruction:The PLC-ATP separating plate is required at the start and end of every PLC terminal strip.

Product properties

Product familyPLC-INTERFACE
ApplicationFilter to prevent interference
Operating mode100% operating factor
Mechanical service lifeapprox. 3x 107 cycles

Insulation characteristics

InsulationBasic insulation

Insulation characteristics: Air clearances and creepage distances between the power circuits

InsulationBasic insulation
Overvoltage categoryIII
Pollution degree3

Electrical properties

Maximum power dissipation for nominal condition2.3 W
Test voltage (Winding/contact)4 kVrms (50 Hz, 1 min., winding/contact)

Air clearances and creepage distances between the power circuits

Rated Insulation Voltage250 V AC
Rated surge voltage4 kV (Safe isolation, reinforced insulation, and 6 kV between input circuit and output contact current paths)

Coil side

Nominal input voltage UN230 V AC
Nominal input voltage UN220 V DC
Input voltage range179.4 V AC ... 264.5 V AC (20 °C)
Input voltage range171.6 V DC ... 253 V DC (20 °C)
Mains frequency50/60 Hz
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN8.5 mA (50 Hz)
Typical input current at UN10 mA (60 Hz)
Typical response time7 ms
Typical release time10 ms
Typical release voltage60 V AC
Coil Voltage110 V DC
Protective circuitRC element
Protective circuitBridge rectifier
Status displayYellow LED

Switching

Contact switching type1 changeover contact
Type of switch contactSingle contact
Contact MaterialAgNi
Maximum Switching Voltage250 V AC/DC
Minimum Switching Voltage12 V (10 mA)
Limiting Continuous Current6 A
Limiting Continuous Current10 A (value applies to connections 12. If connections 12 are bridged, the normal value applies.)
Maximum Inrush Current30 A (300 ms, N/O contact)
Min. switching current10 mA (12 V)
Interrupting rating (ohmic load) max.144 W (24 V DC)
Interrupting rating (ohmic load) max.240 W (24 V DC, value is valid for connections 12. If connections 12 are bridged, the normal value applies.)
Interrupting rating (ohmic load) max.58 W (48 V DC)
Interrupting rating (ohmic load) max.48 W (60 V DC)
Interrupting rating (ohmic load) max.50 W (110 V DC)
Interrupting rating (ohmic load) max.80 W (220 V DC)
Interrupting rating (ohmic load) max.1500 VA (250 V AC)
Interrupting rating (ohmic load) max.2500 W (250 V AC, value is valid for connections 12. If connections 12 are bridged, the normal value applies.)
Switching capacity2 A (DC13, 24 V)
Switching capacity0.2 A (DC13, 250 V)
Switching capacity6 A (AC15, 24 V)
Switching capacity6 A (AC15, 250 V)

Connection data

Connection MethodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm² (Single ferrule)
Conductor cross section flexible2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG26 ... 14
Tightening torque0.6 Nm ... 0.8 Nm

Dimensions

Width14 mm
Height80 mm
Depth94 mm

Material specifications

Colorgray (RAL 7042)

Ambient conditions

Degree of protection (Relay base)IP20 (Relay base)
Degree of protection (Relay)RT II (Relay)
Degree of protection (Installation location)IP54 (Installation location)
Ambient Temperature (Operation)-40 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m

CE

CertificateCE-compliant

UKCA

CertificateUKCA-compliant

Shipbuilding approval

CertificateTAE0000196

Corrosive gas test

IdentificationISA-S71.04. G3 Harsh Group
IdentificationEN 60068-2-60

DNV GL data

TemperatureD
HumidityA
VibrationB/C
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive
Electromagnetic compatibilityConformance with EMC directive

Air clearances and creepage distances between the power circuits

Standards/regulationsIEC 60947-5-1

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsin rows with zero spacing
Mounting Positionany

Why Proax for Phoenix Contact PLC-RSC-230UC/21HC/SO46?

Proax is an authorized distributor of Phoenix Contact PLC-RSC-230UC/21HC/SO46 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesPLCRSC230UC21HCSO46
Pack Size10
Recommended
Sold in quantities of 10

Available for order