Official Distributor
SKU
MPN
PLC-RSC-230UC/21-21/SO46
Weight
0.079 kg
This product is Not Cancellable/Not Returnable
Series PLC-RSC
PLC-RSC-230UC/21-21/SO46 - Relay Module
PLC-INTERFACE with protection against interference currents/voltages on the control side, consisting of PLC-BSC.../21 basic terminal block with screw connection and plug-in miniature relay with power contact, 2 changeover contacts, input voltage 230 V AC
Technical Specifications
Product properties
Product family | PLC-INTERFACE |
Application | Filter to prevent interference |
Operating mode | 100% operating factor |
Mechanical service life | 3x 107 cycles |
Insulation characteristics
Insulation | Basic insulation |
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation | Basic insulation |
Overvoltage category | III |
Pollution degree | 3 |
Electrical properties
Maximum power dissipation for nominal condition | 1.04 W |
Test voltage (Winding/contact) | 4 kV AC (50 Hz, 1 min., winding/contact) |
Test voltage (Changeover contact/changeover contact) | 2.5 kV AC (50 Hz, 1 min., changeover contact/changeover contact) |
Air clearances and creepage distances between the power circuits
Rated Insulation Voltage | 250 V AC |
Rated surge voltage | 4 kV (Safe isolation, reinforced insulation, and 6 kV between input circuit and output contact current paths) |
Coil side
Nominal input voltage UN | 230 V AC |
Nominal input voltage UN | 220 V DC |
Input voltage range | 179.4 V AC ... 264.5 V AC (20 °C) |
Input voltage range | 171.6 V DC ... 253 V DC (20 °C) |
Mains frequency | 50/60 Hz |
Drive and function | monostable |
Drive (polarity) | polarized |
Typical input current at UN | 9 mA |
Typical response time | 7 ms |
Typical release time | 10 ms |
Typical release voltage | 60 V AC/DC |
Protective circuit | Bridge rectifier |
Status display | Yellow LED |
Switching
Contact switching type | 2 changeover contacts |
Type of switch contact | Single contact |
Contact Material | AgNi |
Maximum Switching Voltage | 250 V AC/DC |
Minimum Switching Voltage | 5 V (10 mA) |
Limiting Continuous Current | 6 A |
Maximum Inrush Current | 15 A (300 ms) |
Min. switching current | 10 mA (5 V) |
Interrupting rating (ohmic load) max. | 140 W (24 V DC) |
Interrupting rating (ohmic load) max. | 85 W (48 V DC) |
Interrupting rating (ohmic load) max. | 60 W (60 V DC) |
Interrupting rating (ohmic load) max. | 44 W (110 V DC) |
Interrupting rating (ohmic load) max. | 60 W (220 V DC) |
Interrupting rating (ohmic load) max. | 1500 VA (250 V AC) |
Switching capacity | 2 A (at 24 V, DC13) |
Switching capacity | 0.2 A (at 250 V, DC13) |
Switching capacity | 3 A (at 24 V, AC15) |
Switching capacity | 3 A (at 120 V, AC15) |
Switching capacity | 3 A (at 250 V, AC15) |
Connection data
Connection Method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² (Single ferrule) |
Conductor cross section flexible | 2x 0.5 mm² ... 1.5 mm² (TWIN ferrule) |
Conductor cross section AWG | 26 ... 14 |
Tightening torque | 0.6 Nm ... 0.8 Nm |
Dimensions
Width | 14 mm |
Height | 80 mm |
Depth | 94 mm |
Material specifications
Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V0 (Housing) |
Ambient conditions
Degree of protection (Relay) | RT III (Relay) |
Degree of protection (Relay base) | IP20 (Relay base) |
Ambient Temperature (Operation) | -40 °C ... 55 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
CE
Certificate | CE-compliant |
UKCA
Certificate | UKCA-compliant |
Shipbuilding approval
Certificate | TAE0000196 |
Corrosive gas test
Identification | ISA-S71.04. G3 Harsh Group |
Identification | EN 60068-2-60 |
DNV GL data
Temperature | D |
Humidity | A |
Vibration | B/C |
EMC | B |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
Low Voltage Directive | Conformance with Low Voltage Directive |
Electromagnetic compatibility | Conformance with EMC directive |
Air clearances and creepage distances between the power circuits
Standards/regulations | IEC 60947-5-1 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | in rows with zero spacing |
Mounting Position | any |
Why Proax for Phoenix Contact 2980500?
Proax is an authorized distributor of Phoenix Contact 2980500 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 10 |
Recommended