Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
FA MCR-EX-HT-TS-I-OLP-PT
Weight
0.197 kg

FA MCR-EX-HT-TS-I-OLP-PT - Head-mounted transducer

The output loop-powered head transmitter transmits up to two sensor signals from RTD and TC sensors as well as from resistance-type sensors and voltage sensors via HART communication or 4 ... 20 mA, configurable. SIL 2/3, intrinsic safety.

Technical Specifications

Product properties

Product familyField Analog

Insulation characteristics

Overvoltage categoryII
Pollution degree2

Electrical properties

Step response (0–99%)0.8 s (TC)

Electrical isolation Input/output

Test voltage2 kV AC

Supply

Supply Voltage Rangeloop-powered, no external supply necessary
Supply Voltage Range11 V ... 42 V (Standard)
Supply Voltage Range11 V ... 32 V (SIL active)
Supply Voltage Range11 V ... 30 V (Ex)

Measurement

Input voltage range-20 mV ... 100 mV
Sensor types (RTD) that can be usedPt, Ni, Cu sensors: 2, 3, 4-wire
Sensor types that can be used (TC)A, B, C, D, E, J, K, L, N, R, S, T, U
Temperature measuring range-250 °C ... 2500 °C (Range depending on the sensor type)
Temperature measuring range-200 °C ... 850 °C (Pt 100)
Temperature measuring range> 10 K (RTD)
Temperature measuring range> 50 K (TC)
Linear resistance measuring range10 Ω ... 2000 Ω (Minimum measuring span: 10 Ω)

Signal

Current Output Signal4 mA ... 20 mA (HART)
Current Output Signal20 mA ... 4 mA (HART)
Max. current output signal23 mA
Load(UL - 11 V) / 0,023 A
HART codingFSK ± 0.5 mA
HART version7
Transmission Speed1200 Baud
Mains frequency filter50/60 Hz
Communication resistance≥ 250 Ω
Switch-on delayapprox. 10 s (HART)
Switch-on delayapprox. 28 s (Measured value)

Connection data

Connection MethodPush-in connection
Stripping length10 mm
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16

Ambient conditions

Degree of ProtectionIP33 (upon installation in field housing IP66/67, NEMA 4X)
Ambient Temperature (Operation)-40 °C ... 85 °C
Ambient Temperature (Operation)-40 °C ... 70 °C (SIL active)
Ambient temperature (storage/transport)-50 °C ... 100 °C
Altitude≤ 4000 m (Above sea level)
Climatic classC1
Permissible humidity (operation)5 % ... 95 % (condensation permitted)

CE

CertificateCE-compliant

ATEX

Identification II 1G Ex ia IIC T6...T4 Ga
Identification II 2G Ex ia IIC T6...T4 Gb
CertificateEPS 17 ATEX 1 130 X

IECEx

IdentificationEx ia IIC T6...T4 Ga
IdentificationEx ia IIC T6...T4 Gb
CertificateIECEx EPS 17.0076X

UL, USA/Canada

IdentificationUL 61010 Recognized

FM

IdentificationNI / Class I / Div. 1, 2 / Group ABCD T6/T5/T4
IdentificationIS / Class I / Div. 1, 2 / Group ABCD

CSA

IdentificationExia / Class I / Group ABCD T6/T5/T4

Mounting

Assembly instructionsInstallation in connection head according to DIN 43729 form B

Why Proax for Phoenix Contact 2908743?

Proax is an authorized distributor of Phoenix Contact 2908743 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability