Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
FA MCR-HT-1TS-I-OLP
Weight
0.187 kg

FA MCR-HT-1TS-I-OLP - Head-mounted transducer

Output loop-powered head transmitter for transmitting RTD and TC sensor signals, as well as from resistance and voltage sensors via 4 mA ... 20 mA. HART, Standard configuration, Screw connection

Technical Specifications

Product properties

Product familyField Analog
No. of channels1
ConfigurationSoftware
ConfigurationHART

Insulation characteristics

Overvoltage categoryII
Pollution degree2

Electrical properties

Step response (0–99%)1 s (TC)
Step response (0–99%)1 s (RTD)

Electrical isolation Input/output

Test voltage2 kV AC (50 Hz, 60 s)

Supply

Supply Voltage Rangeloop-powered, no external supply necessary
Supply Voltage Range10 V DC ... 36 V DC (Standard)

Measurement

Number of Inputs1
Input voltage range-20 mV ... 100 mV (Minimum measuring span: 5 mV)
Sensor types (RTD) that can be usedPt, Ni, Cu sensors: 2, 3, 4-wire
Sensor types that can be used (TC)A, B, C, D, E, J, K, L, N, R, S, T, U
Temperature measuring range-250 °C ... 2500 °C (Range depending on the sensor type)
Temperature measuring range≥ 10 K (RTD)
Temperature measuring range≥ 50 K (TC)
Linear resistance measuring range10 Ω ... 2000 Ω (Minimum measuring span: 10 Ω)

Signal: Current

Current Output Signal4 mA ... 20 mA (HART)
Current Output Signal20 mA ... 4 mA (HART)
Max. current output signal23 mA
Load(UL - 10 V) / 0.023 A
HART codingFSK ± 0.5 mA
HART version7
Transmission Speed1200 Baud
Mains frequency filter50/60 Hz
Communication resistance≥ 250 Ω
Switch-on delay 7 s (HART)
Switch-on delay 7 s (Measured value)

Connection data

Connection MethodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Tightening torque0.5 Nm

Ex data

Ex installation (EPL)Gc
Ex installation (EPL)Div. 2

Data communication (bypass)

Protocols SupportedHART

Ambient conditions

Degree of ProtectionIP00 (upon installation in field housing IP66/67, NEMA 4X)
Ambient Temperature (Operation)-40 °C ... 85 °C
Ambient temperature (storage/transport)-50 °C ... 100 °C
Altitude≤ 4000 m (Above sea level)
Climatic classC1
Permissible humidity (operation)5 % ... 95 % (condensation permitted)

CE

CertificateCE-compliant

ATEX

Identification II 3 G Ex ec IIC T6
CertificatePxCIF20ATEX1145192U

CSA

IdentificationEx ec IIC T6...T4

Mounting

Mounting TypeInstallation
Mounting TypeDIN rail mounting
Assembly instructionsInstallation in connecting head B in accordance with DIN EN 50446

Why Proax for Phoenix Contact 1145210?

Proax is an authorized distributor of Phoenix Contact 1145210 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery