
SKU
MPN
FA MCR-HT-TS-I-OLP-PT
Weight
0.197 kg
FA MCR-HT-TS-I-OLP-PT - Head-mounted transducer
The output-loop-powered head transmitter transmits up to two sensor signals from RTD and TC sensors as well as from resistance-type sensors and voltage sensors and via HART_communication or 4 ... 20 mA, configurable. SIL2/3
Technical Specifications
Product properties
Product family | Field Analog |
Insulation characteristics
Overvoltage category | II |
Pollution degree | 2 |
Electrical properties
Step response (0–99%) | 0.8 s (TC) |
Electrical isolation Input/output
Test voltage | 2 kV AC |
Supply
Supply Voltage Range | loop-powered, no external supply necessary |
Supply Voltage Range | 11 V ... 42 V (Standard) |
Supply Voltage Range | 11 V ... 32 V (SIL active) |
Measurement
Input voltage range | -20 mV ... 100 mV |
Sensor types (RTD) that can be used | Pt, Ni, Cu sensors: 2, 3, 4-wire |
Sensor types that can be used (TC) | A, B, C, D, E, J, K, L, N, R, S, T, U |
Temperature measuring range | -250 °C ... 2500 °C (Range depending on the sensor type) |
Temperature measuring range | -200 °C ... 850 °C (Pt 100) |
Temperature measuring range | > 10 K (RTD) |
Temperature measuring range | > 50 K (TC) |
Linear resistance measuring range | 10 Ω ... 2000 Ω (Minimum measuring span: 10 Ω) |
Signal
Configurable/programmable | no |
Current Output Signal | 4 mA ... 20 mA (HART) |
Current Output Signal | 20 mA ... 4 mA (HART) |
Max. current output signal | 23 mA |
Load | (UB – 11 V) / 0.023 A |
HART coding | FSK ± 0.5 mA |
HART version | 7 |
Transmission Speed | 1200 Baud |
Mains frequency filter | 50/60 Hz |
Communication resistance | ≥ 250 Ω |
Switch-on delay | approx. 10 s (HART) |
Switch-on delay | approx. 28 s (Measured value) |
Connection data
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Ambient conditions
Degree of Protection | IP33 (upon installation in field housing IP66/67, NEMA 4X) |
Ambient Temperature (Operation) | -40 °C ... 85 °C |
Ambient Temperature (Operation) | -40 °C ... 70 °C (SIL active) |
Ambient temperature (storage/transport) | -50 °C ... 100 °C |
Altitude | ≤ 4000 m (Above sea level) |
Climatic class | C1 |
Permissible humidity (operation) | 5 % ... 95 % (condensation permitted) |
CE
Certificate | CE-compliant |
ATEX
Identification | II 3G Ex nA IIC T6...T4 Gc |
UL, USA/Canada
Identification | UL 61010 Recognized |
FM
Identification | NI / Class I / Div. 1, 2 / Group ABCD T6/T5/T4 |
CSA
Identification | NI, Class I, Div. 2, Groups A, B, C, D |
Mounting
Assembly instructions | Installation in connecting head B in accordance with DIN EN 50446 |
Accessories
Why Proax for Phoenix Contact 2908742?
Proax is an authorized distributor of Phoenix Contact 2908742 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended