Series PLC-RPT

PLC-RPT-230UC/21-21AU/RWF - Relay Module

PLC-INTERFACE for railway applications, consisting of basic terminal block with Push-in connection and plug-in miniature relay with multi-layer gold contact, range: 0.75 x UN to 1.15 x UN, nominal input frequency 16.7 Hz, 2 changeover contacts, input voltage 230 V AC

  • Vibration and shock resistance in accordance with EN 50155
  • Safe isolation between coil and contact side
  • Nominal input frequency of 16.7 Hz
  • Screw, spring-cage or Push-in connection
Technical Specifications

Product properties

Product familyPLC-INTERFACE
ApplicationRailway applications
Operating mode100% operating factor
Mechanical service lifeapprox. 3x 107 cycles

Insulation characteristics

InsulationBasic insulation

Insulation characteristics: Air clearances and creepage distances between the power circuits

InsulationBasic insulation
Overvoltage categoryIII
Pollution degree2

Electrical properties

Maximum power dissipation for nominal condition1.1 W
Test voltage (Winding/contact)6 kV (50 Hz, 1 min., winding/contact)

Air clearances and creepage distances between the power circuits

Rated Insulation Voltage250 V AC
Rated surge voltage6 kV

Coil side

Nominal input voltage UN230 V AC
Input voltage range172.5 V AC ... 264.5 V AC (20 °C)
Mains frequency16.67 Hz
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN4.8 mA (with AC)
Typical response time20 ms
Typical release time60 ms
Coil Voltage110 V DC
Protective circuitBridge rectifier
Operating voltage displayYellow LED

Switching

Contact switching type2 changeover contacts
Type of switch contactSingle contact
Contact MaterialAgNi, hard gold-plated
NoteIf the specified maximum values are exceeded, the gold plating is destroyed. The AgNi contact values are then valid for further operation; a reduction in length of service life is to be expected.
Maximum Switching Voltage30 V AC
Maximum Switching Voltage36 V DC
Minimum Switching Voltage100 mV
Limiting Continuous Current50 mA
Maximum Inrush Current50 mA
Min. switching current1 mA
Interrupting rating (ohmic load) max.1.2 W (24 V DC)
Switching capacity2 A (24 V (DC13), in acc. with DIN VDE 0660/IEC 60947)
Switching capacity0.2 A (220 V DC / 230 V AC (DC13), in acc. with DIN VDE 0660/IEC 60947)
Switching capacity3 A (220 V DC / 230 V AC (AC15), in acc. with DIN EVDE 0660/IEC 60947)

Switching: when the gold layer is destroyed

Notethe following values are applicable if a gold layer is destroyed
Contact MaterialAgNi
Maximum Switching Voltage250 V AC/DC (Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules.)
Minimum Switching Voltage5 V AC/DC
Limiting Continuous Current6 A
Maximum Inrush Current8 A
Min. switching current10 mA
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
Interrupting rating (ohmic load) max.85 W (at 48 V DC)
Interrupting rating (ohmic load) max.60 W (at 60 V DC)
Interrupting rating (ohmic load) max.44 W (at 110 V DC)
Interrupting rating (ohmic load) max.60 W (at 220 V DC)
Interrupting rating (ohmic load) max.1500 VA (for 250 V AC)
Switching capacity2 A (at 24 V, DC13)
Switching capacity0.2 A (at 110 V, DC13)
Switching capacity0.2 A (at 250 V, DC13)
Switching capacity2 A (at 24 V, AC15)
Switching capacity2 A (at 120 V, AC15)
Switching capacity2 A (at 250 V, AC15)

Connection data

Connection MethodPush-in connection
Stripping length10 mm
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm² (Single ferrule)
Conductor cross section flexible2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG26 ... 14

Dimensions

Width14 mm
Height80 mm
Depth94 mm

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)

Ambient conditions

Degree of protection (Relay)RT III (Relay)
Degree of protection (Relay base)IP20 (Relay base)
Ambient Temperature (Operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

CE

CertificateCE-compliant

Corrosive gas test

IdentificationISA-S71.04. G3 Harsh Group
IdentificationEN 60068-2-60

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive
Electromagnetic compatibilityConformance with EMC directive

Air clearances and creepage distances between the power circuits

Standards/regulationsIEC 60947-5-1

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsin rows with zero spacing
Mounting Positionany
Accessories

Why Proax for Phoenix Contact PLC-RPT-230UC/21-21AU/RWF?

Proax is an authorized distributor of Phoenix Contact PLC-RPT-230UC/21-21AU/RWF and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesPLCRPT230UC2121AURWF
Pack Size10
Recommended
Sold in quantities of 10

Available for order

Phoenix Contact Availability