
1136242
PLC-RPT-230UC/21HC/SO46 - Relay Module
PLC-INTERFACE for protection against interference currents or interference voltages on the control side. Consisting of basic terminal block with Push-in connection and plug-in miniature relay with power contact up to 10 A, 1 changeover contact, 230 V AC input voltage
PLC-RPT
Phoenix Contact PLC-RPT Series – Compact relay modules for reliable switching in control cabinets and industrial automation systems. Features slim DIN-rail design with push-in terminals for tool-free installation.
Series Options:
- Universal Relays: Standard switching with single/dual changeover contacts
- High-Current (HC): Up to 10 A continuous load capacity
- Gold-Plated (AU): Optimized for low-power signal switching
- Manual Switch (MS): Integrated test buttons and LED indication
- Voltage Range: 12 V DC to 230 V AC/DC compatibility
Key Benefits: Space-saving slim profile, tool-free push-in connections, comprehensive voltage and contact options, LED status indication available, and reliable performance in demanding industrial environments.
Applications: Industrial automation, control panel switching, signal isolation, and load control.
Notes
| Notes on operation | The PLC-ATP partition plate must be installed for voltages greater than 250 V (L1, L2, L3) between identical terminal blocks on adjacent modules. |
| Notes on operation | The PLC-ATP separating plate should be installed for safe isolation between adjacent modules |
| Notes on operation | The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact. |
| Assembly instruction: | The PLC-ATP separating plate is required at the start and end of every PLC terminal strip. |
Product properties
| Product family | PLC-INTERFACE |
| Application | Filter to prevent interference |
| Operating mode | 100% operating factor |
| Mechanical service life | approx. 3x 10⁷ cycles |
Insulation characteristics
| Insulation | Basic insulation |
Insulation characteristics: Air clearances and creepage distances between the power circuits
| Insulation | Basic insulation |
| Overvoltage category | III |
| Pollution degree | 3 |
Electrical properties
| Maximum power dissipation for nominal condition | 2.3 W |
| Test voltage (Winding/contact) | 4 kVrms (50 Hz, 1 min., winding/contact) |
Air clearances and creepage distances between the power circuits
| Rated Insulation Voltage | 250 V AC |
| Rated surge voltage | 4 kV (Safe isolation, reinforced insulation, and 6 kV between input circuit and output contact current paths) |
Coil side
| Nominal input voltage UN | 230 V AC |
| Nominal input voltage UN | 220 V DC |
| Input voltage range | 179.4 V AC ... 264.5 V AC (20 °C) |
| Input voltage range | 171.6 V DC ... 253 V DC (20 °C) |
| Mains frequency | 50/60 Hz |
| Drive and function | monostable |
| Drive (polarity) | polarized |
| Typical input current at UN | 8.5 mA (50 Hz) |
| Typical input current at UN | 10 mA (60 Hz) |
| Typical response time | 7 ms |
| Typical release time | 10 ms |
| Typical release voltage | 60 V AC |
| Coil Voltage | 110 V DC |
| Protective circuit | RC element |
| Protective circuit | Bridge rectifier |
| Status display | Yellow LED |
Switching
| Contact switching type | 1 changeover contact |
| Type of switch contact | Single contact |
| Contact Material | AgNi |
| Maximum Switching Voltage | 250 V AC/DC |
| Minimum Switching Voltage | 12 V (10 mA) |
| Limiting Continuous Current | 6 A |
| Limiting Continuous Current | 10 A (value applies to connections 12. If connections 12 are bridged, the normal value applies.) |
| Maximum Inrush Current | 30 A (300 ms, N/O contact) |
| Min. switching current | 10 mA (12 V) |
| Interrupting rating (ohmic load) max. | 144 W (24 V DC) |
| Interrupting rating (ohmic load) max. | 240 W (24 V DC, value is valid for connections 12. If connections 12 are bridged, the normal value applies.) |
| Interrupting rating (ohmic load) max. | 58 W (48 V DC) |
| Interrupting rating (ohmic load) max. | 48 W (60 V DC) |
| Interrupting rating (ohmic load) max. | 50 W (110 V DC) |
| Interrupting rating (ohmic load) max. | 80 W (220 V DC) |
| Interrupting rating (ohmic load) max. | 1500 VA (250 V AC) |
| Interrupting rating (ohmic load) max. | 2500 W (250 V AC, value is valid for connections 12. If connections 12 are bridged, the normal value applies.) |
| Switching capacity | 2 A (DC13, 24 V) |
| Switching capacity | 0.2 A (DC13, 250 V) |
| Switching capacity | 6 A (AC15, 24 V) |
| Switching capacity | 6 A (AC15, 250 V) |
Connection data
| Connection Method | Push-in connection |
| Stripping length | 10 mm |
| Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² (Single ferrule) |
| Conductor cross section flexible | 2x 0.5 mm² ... 1 mm² (TWIN ferrule) |
| Conductor cross section AWG | 26 ... 14 |
Dimensions
| Width | 14 mm |
| Height | 80 mm |
| Depth | 94 mm |
Material specifications
| Color | gray (RAL 7042) |
Ambient conditions
| Degree of protection (Relay base) | IP20 (Relay base) |
| Degree of protection (Relay) | RT II (Relay) |
| Degree of protection (Installation location) | IP54 (Installation location) |
| Ambient Temperature (Operation) | -40 °C ... 55 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Altitude | ≤ 2000 m |
CE
| Certificate | CE-compliant |
UKCA
| Certificate | UKCA-compliant |
Shipbuilding approval
| Certificate | TAE0000196 |
Corrosive gas test
| Identification | ISA-S71.04. G3 Harsh Group |
| Identification | EN 60068-2-60 |
DNV GL data
| Temperature | D |
| Humidity | A |
| Vibration | B/C |
| EMC | B |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board |
EMC data
| Low Voltage Directive | Conformance with Low Voltage Directive |
| Electromagnetic compatibility | Conformance with EMC directive |
Air clearances and creepage distances between the power circuits
| Standards/regulations | IEC 60947-5-1 |
Mounting
| Mounting Type | DIN rail mounting |
| Assembly instructions | in rows with zero spacing |
| Mounting Position | any |
Why Proax for Phoenix Contact 1136242?
Proax is an authorized distributor of Phoenix Contact 1136242 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
| Pack Size | 10 |



















