MACX MCR-EX-TC-I - Temperature measuring transducer

Ex i temperature transducer: converts signals from thermocouples installed in Ex areas and mV sources and transmits a 0/4…20 mA signal to a load in the safe area. Freely programmable. 3-way isolation, screw connection, SIL.

  • Input for thermocouples and mV sources
  • Power supply possible via DIN rail connector
  • Programming during operation with Ex measuring circuit connected and also voltage-free using IFS-USB-PROG-ADAPTER programming adapter
  • Installation in zone 2, protection type "ec" (EN 60079-7) permitted
  • 3-way electrical isolation
  • Status indicator for supply voltage, cable, sensor, and module errors
  • Configuration via software (FDT/DTM): sensor type, connection technology, measuring range, measuring unit, filter, alarm signal, and output range
  • Output: 0 mA ... 20 mA or 4 mA ... 20 mA
Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties

Product familyMACX Analog
ApplicationTemperature
No. of channels1
TypeEx i signal conditioners with SIL functional safety
ConfigurationSoftware

Insulation characteristics: GB Standard

Overvoltage categoryII
Pollution degree2

Electrical properties

Electrical isolation3-way isolation
Electrical isolation between input and outputNo
Cold point error, max.± 2 K
Step response (0–99%)1 s
Step response (0–99%)≤ 1.7 s
Temperature coefficient, typical0.01 %/K
Transmission error, typical0.1 % (For full identification of transmission errors, see the data sheet)

Electrical isolation Input/output/power supply

Rated Insulation Voltage300 Vrms
Test voltage2.5 kV AC (50 Hz, 60 s)
InsulationSafe isolation in accordance with IEC/EN 61010-1

Electrical isolation Input/output

Electrical isolation375 V (Peak value in accordance with IEC/EN 60079-11)

Electrical isolation Input/power supply

Electrical isolation375 V (Peak value in accordance with IEC/EN 60079-11)

Supply

Nominal Supply Voltage24 V DC
Supply Voltage Range19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %)
Max. current consumption< 40 mA (24 V DC)
Power dissipation≤ 0.76 W
Power consumption≤ 1 W

Signal

Number of Inputs1
Input SignalTemperature
Input SignalVoltage

Measurement

Description of the inputIntrinsically safe
Sensor types that can be used (TC)B, E, J, K, N, R, S, T, L, U, C, D, A-1, A-2, A-3, M, Lr
Temperature measuring range-250 °C ... 2500 °C (Range depending on the sensor type)
Sensor type: 500 °C ... 1820 °C
Sensor type: -230 °C ... 1000 °C
Sensor type: -210 °C ... 1200 °C
Sensor type: -250 °C ... 1372 °C
Sensor type: -200 °C ... 1300 °C
Sensor type: -50 °C ... 1768 °C
Sensor type: -50 °C ... 1768 °C
Sensor type: -200 °C ... 400 °C
Sensor type: -200 °C ... 900 °C
Sensor type: -200 °C ... 600 °C
Sensor type: 0 °C ... 2315 °C
Sensor type: 0 °C ... 2315 °C
Sensor type: 0 °C ... 2500 °C
Sensor type: 0 °C ... 1800 °C
Sensor type: 0 °C ... 1800 °C
Sensor type: -200 °C ... 100 °C
Sensor type: -200 °C ... 800 °C
Linear mV signal range-1000 mV ... 1000 mV
Temperature measuring rangeMin. 50 K with thermocouple, 10% of the nominal span of the respective range with mV sources

Signal: Current

Number of Outputs1
Configurable/programmableYes
Current Output Signal0 mA ... 20 mA
Current Output Signal4 mA ... 20 mA (SIL)
Load/Output Load Current Output≤ 600 Ω
Output ripple (current)< 15 µAPP
Output ripple (current)< 10 µArms
Behavior in the event of a sensor errorAs per NE 43 or can be freely defined

Connection data

Connection MethodScrew connection
Stripping length7 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Tightening torque0.5 Nm ... 0.6 Nm

Test socket

Max. diameter2 mm

Ex data

Ex installation (EPL)Gc
Ex installation (EPL)Div. 2
Ex i circuits (EPL)Ga
Ex i circuits (EPL)Da
Ex i circuits (EPL)Ma
Ex i circuits (EPL)Div. 1

Safety data: Terminals: 4.1, 4.2, 5.1, 5.2

Max. internal capacitance Ci44 nF
Max. output voltage Uo6 V
Max. output current Io4.3 mA (mV)
Max. output current Io7.1 mA (TC with internal cold junction compensation)
Max. output current Io16.8 mA (TC with external cold junction, TC and cold junction connected)
Max. output power Po25.2 mW (Linear)
Safety-related maximum voltage Um253 V AC
Safety-related maximum voltage Um125 V DC
Safety-related maximum voltage Um30 V DC (Zone 2: 3.1, 3.2)
IIA/I (simple circuit): Max. external inductivity Lo / Max. external capacitance Co850 mH / 1000 µF
IIB/IIIC (simple circuit): Max. external inductivity Lo / Max. external capacitance Co460 mH / 1000 µF
IIC (simple circuit): Max. external inductivity Lo / Max. external capacitance Co100 mH / 40 µF
IIB/IIA (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co100 mH / 950 nF, 50 mH / 950 nF, 5 mH / 950 nF, 1 mH / 950 nF
IIIC/I (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co100 mH / 950 nF, 50 mH / 950 nF, 5 mH / 950 nF, 1 mH / 950 nF
IIC (mixed circuit): Max. external inductivity Lo / Max. external capacitance Co100 mH / 555 nF, 50 mH / 555 nF, 5 mH / 555 nF, 1 mH / 555 nF, 10 µH / 555 nF

Signaling

Status displayGreen LED (supply voltage)
Status displayRed LED, flashing 2.4 Hz (cable error, sensor error on input or output, ERR)
Status displayRed LED, flashing 1.2 Hz (service operation, ERR)
Status displayRed LED, permanently on (module error, ERR)

Dimensions

Width12.5 mm
Height112.5 mm
Depth113.7 mm
Depth NS 35/7,5114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)
Housing MaterialPA 6.6-FR

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 70 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)

Altitude range (≤ 2000 m)

Altitude≤ 2000 m (The technical data refers to altitudes ≤2000 m above mean sea level. For altitudes >2000 m above mean sea level, refer to the data sheet.)
Ambient Temperature (Operation)-40 °C ... 70 °C
Test voltage2.5 kV
Rated Insulation Voltage300 Vrms (IEC/EN 60079-11)
Rated Insulation Voltage375 VPP (IEC/EN 60079-11)

Altitude range (≤ 3000 m)

Height Range> 2000 m ... 3000 m
Ambient Temperature (Operation)-40 °C ... 60 °C
Test voltage2.25 kV
Safety-related maximum voltage Um190 V AC
Safety-related maximum voltage Um110 V DC
Rated Insulation Voltage190 Vrms (IEC/EN 60079-11)

Altitude range (≤ 4000 m)

Height Range> 3000 m ... 4000 m
Ambient Temperature (Operation)-40 °C ... 55 °C
Test voltage2 kV
Safety-related maximum voltage Um60 V AC/DC
Rated Insulation Voltage60 Vrms (IEC/EN 60079-11)

Altitude range (≤ 5000 m)

Height Range> 4000 m ... 5000 m
Ambient Temperature (Operation)-40 °C ... 49 °C
Test voltage1.75 kV
Safety-related maximum voltage Um60 V AC/DC
Rated Insulation Voltage60 Vrms (IEC/EN 60079-11)

CE

CertificateCE-compliant
Noteand EN 61326

ATEX

Identification I (M1) [Ex ia Ma] I
Identification II (1) G [Ex ia Ga] IIC
Identification II (1) D [Ex ia Da] IIIC
Identification II 3(1) G Ex ec ic [ia Ga] IIC T4 Gc
CertificateIBExU19ATEX1006 X

UKCA Ex (UKEX)

Identification I (M1) [Ex ia Ma] I
Identification II (1) G [Ex ia Ga] IIC
Identification II (1) D [Ex ia Da] IIIC
Identification II 3 (1) G Ex ec ic [ia Ga] IIC T4 Gc
CertificateCML 22UKEX3531X

IECEx

Identification[Ex ia Ma] I
Identification[Ex ia Ga] IIC
Identification[Ex ia Da] IIIC
IdentificationEx ec ic [ia Ga] IIC T4 Gc
CertificateIECEx IBE 19.0001 X

CCC / China-Ex

Identification[Ex ia Ga] IIC
Identification[Ex iaD]
IdentificationEx nA ic [ia Ga] IIC T4 Gc
CertificateNEPSI GYJ20.1305X

UL, USA/Canada

IdentificationUL 61010 Listed
IdentificationClass I Div 2; IS for Class I, II, III Div 1
Certificate, C.D.-No 83104549

Shipbuilding approval

CertificateDNV GL TAA00000AG

Safety Integrity Level (SIL, IEC 61508)

Identification2

INMETRO

Identification[Ex ia Ma] I
Identification[Ex ia Ga] IIC
Identification[Ex ia Da] IIIC
IdentificationEx ec ic [ia Ga] IIC T4 Gc
CertificateDNV 21.0064 X

DNV GL data

TemperatureB
HumidityB
VibrationA
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4

Electromagnetic HF field

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value1 %

Fast transients (burst)

DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value1 %

Conducted interference

DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value1 %

Standards and Regulations

Electrical isolation3-way isolation

GB Standard

Standards/regulationsGB 3626.20
Standards/regulationsGB 3836.1
Standards/regulationsGB 3836.4
Standards/regulationsGB 3836.8
Standards/regulationsGB 12476.1
Standards/regulationsGB 12476.4

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 1050233?

Proax is an authorized distributor of Phoenix Contact 1050233 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability