Series PSR-MM

PSR-MM30-2NO-2DO-24DC-SP - Safety relay module

2-channel over-speed and zero-speed safety relay up to SIL 3, Cat. 4, PL e, 2 safe relay outputs, suitable for connecting HTL, TTL, or sine/cosine encoders as well as proximity switches, plug-in Push-in terminal block, width: 22.5 mm

  • Monitoring of up to three different speeds as well as downtime
  • Compatible with a range of motion sensors
  • Easy parameterization and online monitoring with the PSRmotion software, which can be downloaded free of charge
  • Force-guided relay contacts, parameterizable signal outputs
  • Up to Cat. 4/PL e in accordance with EN ISO 13849-1, SIL 3 in accordance with EN IEC 62061, SIL 3 in accordance with IEC 61508
Technical Specifications

Product properties

ApplicationZero-speed safety relay
ApplicationOver-speed safety relay
Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3

Times

Typical response time< 200 ms (For Us autostart)
Typical response time< 150 ms (For Us manual, monitored start)
Delay time range0 s ... 10 s ±10 % (Adjustable switch-on delay for downtime contacts 23/24)
Restart time< 1 s (Boot time)
Recovery time< 1 s

Electrical properties

Maximum power dissipation for nominal condition6.5 W (at US = 26.4 V, UINPUT =30 V, IL² = 72 A²)
Nominal operating mode100% operating factor
InterfacesEncoder
InterfacesProximity switches

Air clearances and creepage distances between the power circuits

Rated Insulation Voltage250 V AC
Rated surge voltage/insulationBasic insulation 4 kV between all current paths and housing
Rated surge voltage/insulationSafe isolation, reinforced insulation 6 kV between input circuit (A1/A2, I1, I2, I3, MI1, MI2, IN1, IN2, S34, MO1, MO2, RJ45, USB) and the enabling current paths (13/14, 23/24)

Supply

DesignationA1/A2
Rated control circuit supply voltage US20.4 V DC ... 26.4 V DC
Rated control circuit supply voltage US24 V DC -15 % / +10 %
Rated control supply current IStyp. 74 mA
Power consumption at UStyp. 1.78 W
Inrush Current< 18 A (Δt = 500 µs at Us)
Filter time2 ms (at A1 in the event of voltage dips at Us)
Protective circuitSerial protection against polarity reversal; 33 V suppressor diode

Digital: Operating mode and monitoring inputs

Description of the inputNPN, IEC 61131-2, type 1
Number of Inputs1 (Non-safety-related start input: S34)
Number of Inputs3 (Safety-related operating mode inputs: I1, I2, I3)
Number of Inputs2 (Safety-related monitoring inputs: MI1, MI2)
Discrepancy time2 s (I1, I2, I3)
Discrepancy time2.5 s (MI1, MI2)
Input voltage range "0" signal0 V DC ... 5 V DC
Input voltage range "1" signal15 V DC ... 30 V DC
Input current range "0" signal0 mA ... 1.5 mA
Inrush Current< 5 mA
Filter timemax. 2 ms (Test pulse width; low test pulses for operating mode and monitoring inputs)
Filter timeTest pulse rate = 5 x Test pulse width
Max. permissible overall conductor resistance150 Ω
Protective circuit33 V suppressor diode
Current consumptiontyp. 4 mA (at US)

Measurement

Input nameProximity switch inputs
Description of the inputNPN, IEC 61131-2, type 1
Number of Inputs2 (Safety-related proximity switch inputs: IN1 IN2)
Input voltage range "0" signal0 V DC ... 5 V DC
Input voltage range "1" signal15 V DC ... 30 V DC
Input current range "0" signal0 mA ... 1.5 mA
Inrush Current< 12 mA
Precision± 2 % (in reference to the parameterized limit value)
Limit frequencymax. 2 kHz (Minimum pulse duration: 45 µs)
Max. permissible overall conductor resistance150 Ω
Protective circuit33 V suppressor diode
Current consumptiontyp. 10 mA (at US)
Input nameEncoder input
Description of the inputTTL, HTL, Sin/Cos
Number of Inputs1 (Safety-related encoder input, RJ45)
Precision± 2 % (in reference to the parameterized limit value)
Limit frequencymax. 400 kHz
Limit frequencymax. 250 kHz For active diagnostic safety encoder
Max. permissible overall conductor resistance150 Ω
HTL Signal form/signal level0 V DC ... 3 V DC (Low)
HTL Signal form/signal level12 V DC ... 30 V DC (High)
TTL Signal form/signal level0 V DC ... 0.9 V DC (Low)
TTL Signal form/signal level2.5 V DC ... 5 V DC (High)
Sine / cosine Signal form/signal level2 V DC ... 3 V DC (1 Vpp differential signal)
Current consumption< 3 mA (Per track for US)

Relay: Enabling current path

Output description2 NO contacts each in series, without delay, floating
Number of Outputs2 (safety-related N/O contacts: 13/14, 23/24)
Contact switching type2 enabling current paths
Contact MaterialAgSnO2
Switching voltagemin. 12 V AC/DC
Switching voltagemax. 250 V AC/DC (Observe the load curve)
Switching capacitymin. 60 mW
Inrush Currentmin. 3 mA
Inrush Currentmax. 6 A
Switching capacity in accordance with IEC 60947-5-14 A (24 V (DC13))
Switching capacity in accordance with IEC 60947-5-15 A (250 V (AC15))
Limiting Continuous Current6 A
Sq. Total current72 A2 (observe derating)
Switching frequencymax. 0.5 Hz
Mechanical service life10x 106 cycles
Output fuse6 A gL/gG

Signal

Output descriptionPNP
Number of Outputs2 (Non-safety-related signal outputs: MO1, MO2)
Voltageapprox. 22 V DC (Us - 2 V)
Currentmax. 100 mA
Maximum Inrush Current500 mA (Δt = 1 ms at Us)
Protective circuit33 V suppressor diode
Short-circuit protectionno

Connection technology

pluggableyes

Conductor connection

Connection MethodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross-section AWG24 ... 16
Stripping length8 mm

Signaling

Status display2x LED green (OUT1, OUT2)
Operating voltage display1 x green LED (PWR)

Dimensions

Width22.5 mm
Height117.5 mm
Depth114.5 mm

Material specifications

Color (Housing)yellow (RAL 1018)
Housing MaterialPolyamide

Safety data

Stop category0

Safety data: EN ISO 13849

Category4
Performance level (PL)e (6 A DC1, 17520 switching cycles/year)

Safety data: IEC 61508 - High demand

Safety Integrity Level (SIL)3

Safety data: EN IEC 62061

Safety Integrity Level (SIL)3 (For applications in SIL 3, the required demand rate for the safety function is once per day.)

Ambient conditions

Degree of ProtectionIP20
Min. degree of protection of inst. locationIP54
Ambient Temperature (Operation)-40 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 70 °C
Maximum altitude≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Shock15g
Vibration (Operation)10 Hz ... 150 Hz, 2g

CE

CertificateCE-compliant

Air clearances and creepage distances between the power circuits

Standards/regulationsDIN EN 50178, EN 60947-5-1

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsSee derating curve
Mounting Positionvertical or horizontal
Accessories

Why Proax for Phoenix Contact 2702358?

Proax is an authorized distributor of Phoenix Contact 2702358 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability