Official Distributor
SKU
MPN
PSR-MM25-1NO-2DO-24DC-SP
Weight
0.144 kg
This product is Not Cancellable/Not Returnable
Series PSR-MM
PSR-MM25-1NO-2DO-24DC-SP - Safety relay module
Safety relay module for sensor-free zero-speed monitoring for 3- and 1-phase motors up to SIL 3, Cat. 3, PL e, 2-channel evaluation of the residual voltage of AC, three-phase, and DC motors, plug-in Push-in terminal block, width: 12.5 mm
- Monitoring of 1 and 3-phase AC or DC motors
- No additional sensors required
- Adjustable delay time from 0.5 s ... 20 s
- Adjustable switching threshold from 50 mV... 500 mV
- 1 enabling current path, 2 digital signal outputs
- Low housing width of just 12.5 mm
- Up to Cat. 3/PL e in accordance with EN ISO 13849-1, SIL 3 in accordance with EN IEC 62061
Technical Specifications
Product properties
Application | Zero-speed safety relay |
Times
Typ. starting time with Us | < 1 s |
Response time | typ. 20 ms (at 50 Hz input frequency) |
Delay time range | 0.5 s ... 20 s ±1 % (K1, K2 can be parameterized) |
Electrical properties
Nominal operating mode | 100% operating factor |
Interfaces | Without sensor |
Air clearances and creepage distances between the power circuits
Rated Insulation Voltage | 250 V AC |
Rated Insulation Voltage | 250 V AC |
Rated Insulation Voltage | 400 V AC with isolation paths between (L1/L2/L3) and the remaining current paths |
Rated Insulation Voltage | 690 V AC (with isolation paths within L1/L2/L3) |
Rated surge voltage/insulation | Basic insulation 4 kV:between all current paths and housingBasic insulation 8 kV:between L1 and L2between L1 and L3between L2 and L3 |
Rated surge voltage/insulation | Safe isolation, reinforced insulation 6 kV:between A1/A2 and 13/14between MO/FO and 13/14Safe isolation, reinforced insulation 8 kV:between L1/L2/L3 and A1/A2between L1/L2/L3 and MO/FObetween L1/L2/L3 and 13/14 |
Supply
Rated control circuit supply voltage US | 20.4 V DC ... 26.4 V DC |
Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
Rated control supply current IS | typ. 50 mA |
Power consumption at US | typ. 1.2 W |
Inrush Current | 5.6 A (Δt = 400 µs at Us) |
Filter time | 1 ms (at A1 in the event of voltage dips at Us) |
Protective circuit | Surge protection; Suppressor diode |
Protective circuit | Protection against polarity reversal for rated control circuit supply voltage |
Measurement
Voltage input signal | max. 690 V AC/DC (at L1/L2/L3) |
Limit frequency | max. 3 kHz (At voltages > 2 VRMS) |
Current consumption | max. 0.35 mA (at L1/L2/L3) |
Relay: Enabling current path
Output description | safety-related N/O contacts |
Number of Outputs | 1 (undelayed) |
Contact switching type | 1 enabling current path |
Contact Material | AgSnO2 |
Switching voltage | min. 24 V AC/DC |
Switching voltage | max. 250 V AC/DC (Observe the load curve) |
Switching capacity | min. 72 mW |
Inrush Current | min. 3 mA |
Inrush Current | max. 5 A |
Limiting Continuous Current | 5 A (observe derating) |
Sq. Total current | 25 A2 (observe derating) |
Switching frequency | max. 0.5 Hz |
Mechanical service life | 10x 106 cycles |
Output fuse | 5 A gL/gG |
Signal
Number of Outputs | 2 (digital, PNP) |
Voltage | 23 V DC (US - 1 V) |
Current | max. 100 mA |
Maximum Inrush Current | 500 mA |
Short-circuit protection | Yes |
Connection technology
pluggable | yes |
Conductor connection
Connection Method | Push-in connection |
Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6) |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6) |
Conductor cross-section AWG | 24 ... 16 |
Stripping length | 8 mm |
Signaling
Status display | 4 x LED Bi-Colour |
Dimensions
Width | 12.5 mm |
Height | 116.6 mm |
Depth | 114.5 mm |
Material specifications
Color (Housing) | yellow (RAL 1018) |
Housing Material | Polyamide |
Safety data
Stop category | 0 |
Safety data: EN ISO 13849
Category | 3 |
Performance level (PL) | e (4 A DC13; 5 A AC15; 17520 switching cycles/year) |
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL) | 3 (4 A DC13; 5 A AC15; 17520 switching cycles/year) |
Safety data: EN IEC 62061
Safety Integrity Level (SIL) | 3 (4 A DC13; 5 A AC15; 17520 switching cycles/year) |
Ambient conditions
Degree of Protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Ambient Temperature (Operation) | -20 °C ... 55 °C (observe derating) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Maximum altitude | max. 2000 m (Above sea level) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Shock | 15g |
Vibration (Operation) | 10 Hz ... 150 Hz, 2g |
CE
Certificate | CE-compliant |
Air clearances and creepage distances between the power circuits
Standards/regulations | DIN EN 50178 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | See derating curve |
Mounting Position | vertical or horizontal |
Accessories
Why Proax for Phoenix Contact 2702356?
Proax is an authorized distributor of Phoenix Contact 2702356 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended