Series PSR-PC
PSR-PC32-2NO-1NC-24-230UC-SC - Coupling relay
Coupling relay for SIL 3 high and low-demand applications, couples digital signals to the I/O, 24 V ... 230 V wide-range input, 2 enabling current paths (1x up to 60 V, 1x up to 250 V) 1 confirmation current path, safe state off applications, plug-in screw terminal block
- Up to SIL 3 in accordance with IEC 61508
- Force-guided contacts in accordance with EN 50205
- Easy proof test according to IEC 61508
- Slim design
- Wide-range input
- Corrosion protection through protective coating on the PCB
Technical Specifications
Utilization restriction
CCCex note | Use in potentially explosive areas is not permitted in China. |
Product properties
Product family | PSRmini |
Application | Safe switch off |
Application | High demand |
Application | Low demand |
Application | Ex |
Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
Times
Typical response time | < 100 ms (with Us when controlled via A1) |
Typical release time | < 200 ms (with Us when controlled via A1) |
Recovery time | < 500 ms |
Electrical properties
Maximum power dissipation for nominal condition | 5.7 W (at IL² = 72 A²) |
Nominal operating mode | 100% operating factor |
Air clearances and creepage distances between the power circuits
Rated Insulation Voltage | 250 V AC |
Rated surge voltage/insulation | Basic insulation 4 kV between all current paths and housing |
Rated surge voltage/insulation | Safe isolation, reinforced insulation 2.5 kV between (93/94) and (31/32, 24V/GND) |
Rated surge voltage/insulation | Safe isolation, reinforced insulation 6 kV:between (A1/A2) and (13/14) and (31/32, 24V/GND)between (A1/A2) and (93/94)between (13/14) and (93/94) |
Supply
Designation | A1/A2 |
Rated control circuit supply voltage US | 24 V AC/DC ... 230 V AC/DC -15 % ... +10 % |
Rated control supply current IS | 75 mA (24 V DC) |
Rated control supply current IS | 34 mA (48 V DC) |
Rated control supply current IS | 97 mA (42 V AC) |
Rated control supply current IS | 28 mA (120 V AC) |
Rated control supply current IS | 16 mA (230 V AC) |
Power consumption at US | 1.8 W (with DC) |
Power consumption at US | 2.1 W (with AC) |
Apparent power | typ. 4.1 VA |
Inrush Current | typ. 16 A (Δt < 100 µs at Us) |
Inrush Current | < 5 mA (at terminal blocks 24V/GND at UD) |
Filter time | 10 ms (24 V DC, A1 in the event of voltage dips at Us ) |
Filter time | max. 1.5 ms (at A1-A2; test pulse width; at 24 V DC) |
Filter time | 7.5 ms (at A1-A2; test pulse rate; at 24 V DC) |
Filter time | Test pulse rate = 5 x Test pulse width |
Protective circuit | Surge protection; Varistor 275 V |
Designation | 24V/GND |
Diagnostic supply voltage UD | 24 V DC -15 % / +10 % |
Input current at UD | < 5 mA (at terminal blocks 24V/GND at UD) |
Protective circuit | Surge protection; 33 V suppressor diode |
Protective circuit | Reverse polarity protection |
Relay: Enabling current path
Output description | safety-related N/O contacts |
Number of Outputs | 2 (undelayed) |
Contact switching type | 2 enabling current paths |
Contact Material | AgSnO2 |
Switching voltage | min. 12 V AC/DC |
Switching voltage | max. 250 V AC/DC (13/14, observe the load curve) |
Switching voltage | max. 60 V AC/DC (93/94, observe the load curve) |
Switching capacity | min. 60 mW |
Inrush Current | min. 3 mA |
Inrush Current | max. 6 A |
Switching capacity (360/h cycles) | 4 A (24 V (DC13)) |
Switching capacity (360/h cycles) | 5 A (230 V (AC 15)) |
Limiting Continuous Current | 6 A (observe derating) |
Sq. Total current | 72 A2 (observe derating) |
Switching frequency | max. 1 Hz |
Mechanical service life | 10x 10⁶ cycles |
Output fuse | 6 A gL/gG |
Output fuse | 4 A gL/gG (for low-demand applications) |
Relay: Confirmation current path
Output description | Safety-related N/C contacts |
Number of Outputs | 1 (undelayed) |
Contact switching type | 1 confirmation current path |
Contact Material | AgCuNi, + Au |
Switching voltage | min. 3.3 V AC/DC |
Switching voltage | max. 26.4 V DC |
Switching capacity | min. 3.3 mW |
Inrush Current | min. 1 mA |
Inrush Current | max. 100 mA |
Limiting Continuous Current | 100 mA |
Output fuse | 150 mA fast blow |
Connection technology
pluggable | yes |
Conductor connection
Connection Method | Screw connection |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross-section AWG | 24 ... 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Signaling
Status display | 1 x green LED, 1 x yellow LED |
Operating voltage display | 1 x yellow LED |
Dimensions
Width | 17.5 mm |
Height | 112.2 mm |
Depth | 114.5 mm |
Material specifications
Color (Housing) | yellow (RAL 1018) |
Housing Material | Polyamide |
Safety data
Stop category | 0 |
Safety data: EN 50156-2
Safety Integrity Level (SIL) | 3 (Reference IEC 61508) |
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL) | 3 (< 15% of the overall SIL) |
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL) | 3 (< 15% of the overall SIL) |
Ambient conditions
Degree of Protection | IP20 |
Min. degree of protection of inst. location | IP54 |
Ambient Temperature (Operation) | -40 °C ... 70 °C (observe derating) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Maximum altitude | ≤ 2000 m (Above sea level) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Shock | 15g |
Vibration (Operation) | 10 Hz ... 150 Hz, 2g |
ATEX
Identification | II 3G Ex ec nC IIC T4 Gc |
Certificate | UL 22 ATEX 2912X |
IECEx
Identification | Ex ec nC IIC T4 Gc |
Certificate | IECEx UL 22.0037X |
UL, USA/Canada
Identification | cULus |
Certificate | E140324 |
UL Ex, USA / Canada
Identification | Class I, Zone 2, AEx nA nC IIC T4 / Ex nA nC IIC Gc T4 X |
Identification | Class I, Div. 2, Groups A, B, C, D, T4 |
Certificate | E360692 |
CE
Identification | CE-compliant |
Environmental simulation test
Identification | G3 |
Certificate | ISA-S71.04 |
CCC / China-Ex
Identification | Ex ec nC IIC T4 Gc |
Certificate | 2022122304115695 |
Air clearances and creepage distances between the power circuits
Standards/regulations | EN 60664-1, EN 60079-7, EN 60079-15 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | See derating curve |
Mounting Position | vertical or horizontal |
Why Proax for Phoenix Contact 2700581?
Proax is an authorized distributor of Phoenix Contact 2700581 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- PSR-PC32-2NO-1NC-24-230UC-SP - Coupling relay for SIL 3 high and low-demand applications, couples digital signals to the I/O, 24 V ... 230 V wide-range input, 2 enabling current paths (1x up to 60 V, 1x up to 250 V) 1 confirmation current path, safe state off applications, pluggable Push-in terminal block
- PSR-PC20-1NO-1NC-24DC-SP - Coupling relay for SIL 3 high- and low-demand applications, couples digital output signals to the periphery, 1 enabling current path, 1 confirmation current path, 1 digital signal output, safe state off applications, test pulse filter, TBUS connection, pluggable Push-in terminal block