The figure shows a version with a screw connection
2904665
SKU
PHX2904665
MPN
PSR-PC50-1NO-1DO-24DC-SP
Weight
0.221 kg
Series PSR-PC
PSR-PC50-1NO-1DO-24DC-SP - Coupling relay
Coupling relay for SIL 3 low-demand applications, couples digital output signals to the I/O, 1 enabling current path, module for F&G applications, test pulse filter, width: 17.5 mm, pluggable Push-in terminal block
- Up to SIL 3 in accordance with IEC 61508
- Easy proof test according to IEC 61508 thanks to integrated signal contact
- Installation in zone 2 permitted
- Couples digital output signals from failsafe controllers to I/O devices (valves, etc.) for electrical isolation and power adaptation
Technical Specifications
Utilization restriction
| CCCex note | Use in potentially explosive areas is not permitted in China. |
Product properties
| Product family | PSRmini |
| Application | Safe switch on |
| Application | Low demand |
| Application | Ex |
| Installation location | IP 54 |
| Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
Times
| Typ. starting time with Us | 30 ms (when controlled via A1) |
| Typical release time | 30 ms (when controlled via A1) |
| Recovery time | 1 s |
Electrical properties
| Maximum power dissipation for nominal condition | 1.56 W |
| Nominal operating mode | 100% operating factor |
Air clearances and creepage distances between the power circuits
| Rated Insulation Voltage | 250 V AC |
| Rated surge voltage/insulation | 6 kV/safe isolation (through protective impedance) |
Supply
| Designation | A1/A2 |
| Rated control circuit supply voltage US | 20.4 V DC ... 26.4 V DC |
| Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
| Rated control supply current IS | typ. 65 mA |
| Inrush Current | ≤ 200 mA |
| Filter time | < 2 ms (Test pulse duration) |
| Filter time | ≥ 100 ms (Test pulse rate) |
| Protective circuit | Overload protection; Suppressor diode |
| Designation | 24V/A2 |
| Diagnostic supply voltage UD | 24 V DC -15 % / +10 % |
| Input current at UD | typ. 15 mA (24V/A2; depending on load M1 +100 mA) |
| Inrush current at UD | 2.5 A (24V/A2; for 10 µs) |
| Protective circuit | Overload protection; Suppressor diode |
Digital: Test points for proof test (T1, T2, T3)
| Number of Inputs | 3 (Test point for proof test) |
| Inrush Current | 200 mA (Inputs TP1, TP2 and TP3) |
| Current consumption | typ. 20 mA (Input TP1) |
| Current consumption | typ. 18 mA (Input TP2) |
| Current consumption | typ. 35 mA (Input TP3) |
Relay: Enabling current path
| Output description | safety-related N/O contacts |
| Number of Outputs | 1 (undelayed) |
| Contact switching type | 1 enabling current path |
| Contact Material | AgNi, gold-flashed |
| Switching voltage | min. 15 V AC/DC (without diagnostics) |
| Switching voltage | min. 20 V AC/DC (with diagnostics) |
| Switching voltage | max. 250 V AC |
| Switching voltage | max. 125 V DC |
| Switching capacity | min. 1.5 W |
| Inrush Current | min. 100 mA |
| Inrush Current | max. 5 A |
| Max. permissible overall conductor resistance | < 10 Ω (LO/LO' and NI/NI' and load resistance in the event of a short circuit) |
| Limiting Continuous Current | 5 A |
| Switching frequency | max. 0.5 Hz |
| Diagnostic threshold | 20 Ω ... 18 kΩ (lower/upper) |
| Mechanical service life | approx. 5x 10⁷ cycles |
Signal
| Output description | non-safety-related |
| Number of Outputs | 1 (digital) |
| Voltage | 23 V DC |
| Current | max. 100 mA |
| Short-circuit protection | no |
| Output fuse | 150 mA fast blow |
Connection technology
| pluggable | yes |
Conductor connection
| Connection Method | Push-in connection |
| Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6) |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6) |
| Conductor cross-section AWG | 24 ... 16 |
| Stripping length | 8 mm |
Signaling
| Status display | Green LED |
| Operating voltage display | Yellow LED |
| Error indication | Red LED |
Dimensions
| Width | 17.5 mm |
| Height | 117.4 mm |
| Depth | 114.5 mm |
Material specifications
| Color (Housing) | yellow (RAL 1018) |
| Housing Material | Polyamide |
Safety data: IEC 61508 - Low demand
| Safety Integrity Level (SIL) | 3 (15 % of total SIL) |
Ambient conditions
| Degree of Protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient Temperature (Operation) | -20 °C ... 55 °C |
| Ambient temperature (storage/transport) | -40 °C ... 65 °C |
| Maximum altitude | ≤ 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Shock | 15g |
| Vibration (Operation) | 2g |
ATEX
| Identification | II 3G Ex ec nC IIC T4 Gc |
| Certificate | UL 22 ATEX 2912X |
IECEx
| Identification | Ex ec nC IIC T4 Gc |
| Certificate | IECEx UL 22.0037X |
UL, USA/Canada
| Identification | cULus |
| Certificate | E140324 |
UL Ex, USA / Canada
| Identification | Class I, Zone 2, AEx nA nC IIC T4 / Ex nA nC IIC Gc T4 X |
| Identification | Class I, Div. 2, Groups A, B, C, D, T4 |
| Certificate | E360692 |
CE
| Identification | CE-compliant |
Environmental simulation test
| Identification | G3 |
| Certificate | ISA-S71.04 |
CCC / China-Ex
| Identification | Ex ec nC IIC T4 Gc |
| Certificate | 2022122304115695 |
DNV
| Identification | C, EMC2 |
| Certificate | 11253-14 HH |
Air clearances and creepage distances between the power circuits
| Standards/regulations | EN 60664-1, EN 60079-7, EN 60079-15 |
Mounting
| Mounting Type | DIN rail mounting |
| Mounting Position | vertical or horizontal |
Why Proax for Phoenix Contact 2904665?
Proax is an authorized distributor of Phoenix Contact 2904665 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended
PSR-PC32-2NO-1NC-24-230UC-SC - Coupling relay for SIL 3 high and low-demand applications, couples digital signals to the I/O, 24 V ... 230 V wide-range input, 2 enabling current paths (1x up to 60 V, 1x up to 250 V) 1 confirmation current path, safe state off applications, plug-in screw terminal block
PSR-PC32-2NO-1NC-24-230UC-SP - Coupling relay for SIL 3 high and low-demand applications, couples digital signals to the I/O, 24 V ... 230 V wide-range input, 2 enabling current paths (1x up to 60 V, 1x up to 250 V) 1 confirmation current path, safe state off applications, pluggable Push-in terminal block
PSR-PC20-1NO-1NC-24DC-SP - Coupling relay for SIL 3 high- and low-demand applications, couples digital output signals to the periphery, 1 enabling current path, 1 confirmation current path, 1 digital signal output, safe state off applications, test pulse filter, TBUS connection, pluggable Push-in terminal block