Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
PLC-RSC-24DC/21/EX
Weight
0.041 kg
Series PLC-RSC

PLC-RSC-24DC/21/EX - Relay Module

PLC-INTERFACE, consisting of DIN-rail-mountable basic terminal block in 6.2 mm with screw connection and plug-in miniature relay with 6 A power contact, 1 changeover contact, 24 V DC input voltage. Approved according to ATEX/IECEx (Zone 2) and Ex Zone Class I, Div. 2.

Technical Specifications

Utilization restriction

EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties

Product familyPLC-INTERFACE
ApplicationClass I, Division 2
Applicationpotentially explosive areas
Operating mode100% operating factor
Mechanical service life2x 107 cycles

Insulation characteristics: Standards/regulations

Overvoltage categoryIII
Pollution degree3

Electrical properties

Maximum power dissipation for nominal condition0.22 W
Test voltage (Winding/contact)4 kV AC (50 Hz, 1 min., winding/contact)

Coil side

Nominal input voltage UN24 V DC
Input voltage range18.5 V DC ... 33.6 V DC (20 °C)
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN9 mA
Typical response time5 ms
Typical release time8 ms
Protective circuitReverse polarity protection; Polarity protection diode
Protective circuitFreewheeling diode; Freewheeling diode
Operating voltage displayYellow LED

Switching

Contact switching type1 changeover contact
Type of switch contactSingle contact
Contact connection typePower contact
Contact MaterialAgSnO
Maximum Switching Voltage250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum Switching Voltage5 V (at 100 mA)
Limiting Continuous Current6 A
Maximum Inrush Current10 A (4 s)
Min. switching current10 mA (12 V)
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
Interrupting rating (ohmic load) max.20 W (at 48 V DC)
Interrupting rating (ohmic load) max.18 W (at 60 V DC)
Interrupting rating (ohmic load) max.23 W (at 110 V DC)
Interrupting rating (ohmic load) max.40 W (at 220 V DC)
Interrupting rating (ohmic load) max.1500 VA (for 250 V AC)
Switching capacity2 A (at 24 V, DC13)
Switching capacity0.2 A (at 110 V, DC13)
Switching capacity0.1 A (at 220 V, DC13)
Switching capacity3 A (at 24 V, AC15)
Switching capacity3 A (at 120 V, AC15)
Switching capacity3 A (at 230 V, AC15)

Connection data

Connection MethodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm² (Single ferrule)
Conductor cross section flexible2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG26 ... 14
Tightening torque0.6 Nm ... 0.8 Nm

Dimensions

Width6.2 mm
Height80 mm
Depth94 mm

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)

Ambient conditions

Degree of protection (Relay)RT III (Relay)
Degree of protection (Relay base)IP20 (Relay base)
Ambient Temperature (Operation)-40 °C ... 70 °C (UL)
Ambient Temperature (Operation)-40 °C ... 70 °C (ATEX / IECEx)
Ambient temperature (storage/transport)-40 °C ... 85 °C

CE

CertificateCE-compliant

ATEX

Identification II 3G Ex ec nC IIC T4 Gc
CertificateIBExU16ATEXB015 X

IECEx

IdentificationEx ec nC IIC T4 Gc
CertificateIECEx IBE 16.0029X

UKCA Ex (UKEX)

Identification II 3 G Ex ec nC IIC T4 Gc
CertificatePxCIF21UKEX2909514X

UL, USA

IdentificationClass I, Zone 2, AEx nA nC IIC T6

UL, USA/Canada

IdentificationClass I, Div. 2, Groups A, B, C, D

UL, Canada

IdentificationClass I, Zone 2, Ex nA nC IIC Gc T6 X

Shipbuilding approval

CertificateTAE0000196

Corrosive gas test

IdentificationISA-S71.04. G3 Harsh Group
IdentificationEN 60068-2-60

DNV GL data

TemperatureD
HumidityA
VibrationB/C
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data

Low Voltage DirectiveConformance with Low Voltage Directive
Electromagnetic compatibilityConformance with EMC directive

Standards/regulations

Standards/regulationsIEC 60947-5-1
Standards/regulationsEN 60079-0
Standards/regulationsEN 60079-7
Standards/regulationsEN 60079-15

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsin rows with zero spacing
Mounting Positionany
Accessories

Why Proax for Phoenix Contact 2909524?

Proax is an authorized distributor of Phoenix Contact 2909524 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size10
Recommended
Sold in quantities of 10

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability