SKU
MPN
CAPAROC PM S-R EX
CAPAROC PM S-R EX - Power module
Power module with status output and reset input for supplying the CAPAROC circuit breaker system with 12 V DC or 24 V DC. EX e approval for zone 2. For DIN rail installation via the CAPAROC current rails.
- The customizable standard, thanks to individual combinations of the future-proof modular system
- Easy operation for everyone through tool-free assembly, uninterrupted installation, and transparent operating state
- Strikingly simple design-in with extensive support from the selection up to digital services
Technical Specifications
General
Note | LABS release – in accordance with test specification VW PV 3.10.7:2005-0 |
Note | When connecting the conductor, make sure that the CAPAROC modules are not pulled apart due to tensile force. Gaps must not be created between the modules. |
Note | Observe the specified conditions for use in potentially explosive areas. Install the device in a suitable approved housing with at least IP54 degree of protection that meets the requirements of IEC/EN 60079-0. Also observe the requirements of IEC/EN 60079-14. |
Product properties
Product family | CAPAROC |
Type | Plug-in module |
Number of slots | 2 |
Insulation characteristics
Protection class | III |
Pollution degree | 2 |
General
Operating Voltage | 10 V DC ... 30 V DC |
Rated voltage | 12 V DC |
Rated voltage | 24 V DC |
Rated current IN | 45 A DC (Total current input) |
Rated surge voltage | 0.5 kV |
Tripping method | E (electronic) |
Dielectric strength | 35 V DC (Load circuit) |
Efficiency | > 99 % |
Closed circuit current I0 | typ. 9 mA (no load at 24 V) |
Power dissipation | typ. 0.22 W (no load at 24 V) |
Power dissipation | < 1.5 W (in nominal operation at 24 V and 45 A) |
Temperature derating | 45 A (Total current at 40°C) |
Temperature derating | 30 A (Total current at 65 °C) |
MTBF (IEC 61709, SN 29500) | 18886912.65 h (at 25 °C with 21 % load) |
MTBF (IEC 61709, SN 29500) | 5907048.64 h (at 40°C with 34.25% load) |
MTBF (IEC 61709, SN 29500) | 933563.97 h (at 40°C with 100% load) |
Voltage drop | 0.03 V (at 45 A) |
Reset
Input voltage range | 7 V DC ... 30 V DC (Reset with falling edge) |
Current consumption | typ. 0.5 mA (at 24 V DC) |
Pulse length | ≥ 50 ms |
Stripping length | 8 mm |
Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.2 mm² ... 0.75 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.2 mm² ... 1.5 mm² |
Status output
Output Voltage | max. 30 V DC (Input voltage ±5% in the event of no error) |
Output Voltage | 0 V DC (Error) |
Output Current | max. 20 mA |
Stripping length | 8 mm |
Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.2 mm² ... 0.75 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.2 mm² ... 1.5 mm² |
Output Voltage | max. 30 V DC (Input voltage ±5% when I >80% at at least one channel) |
Output Current | max. 20 mA |
Stripping length | 8 mm |
Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.2 mm² ... 0.75 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.2 mm² ... 1.5 mm² |
Main circuit IN+
Connection Method | Push-in connection |
Stripping length | 18 mm |
Conductor cross section rigid | 0.5 mm² ... 16 mm² |
Conductor cross section AWG | 20 ... 8 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.5 mm² ... 16 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.5 mm² ... 16 mm² |
Main circuit IN-
Connection Method | Push-in connection |
Stripping length | 18 mm |
Conductor cross section rigid | 0.5 mm² ... 16 mm² |
Conductor cross section AWG | 20 ... 8 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.5 mm² ... 16 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.5 mm² ... 16 mm² |
Interfaces
Maximum system extension | ≤ 20 (CAPAROC modules alignable) |
Signaling
Power (PWR) LED green | lit (with no channel errors) |
Power (PWR) LED green | lit (Supply voltage in the nominal range) |
Power (PWR) LED green | flashing (3 x on deactivation of programming lock) |
Power (PWR) LED red | lit (Supply voltage outside the nominal range) |
Power (PWR) LED yellow | flashing (3 x on activation of programming lock) |
Dimensions
Width | 12.4 mm |
Height | 132.4 mm |
Depth | 111.3 mm (incl. DIN rail 7.5 mm) |
Material specifications
Color | light grey (RAL 7035) |
Material | PA 6 |
Material | PA 6 |
Material | PA 6 |
Material | PC |
Flammability rating according to UL 94 | V-0 |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -30 °C ... 65 °C |
Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Altitude | ≤ 4000 m (amsl) |
Humidity test | 96 h, 95 % RH, 40 °C |
Shock (operation) | 30g (11 ms period, half-sine shock pulse, according to IEC 60068-2-27) |
Shock (operation) | 25g (6 ms duration, half-sine shock pulse in accordance with IEC 60068-2-27, continuous shock) |
Vibration (Operation) | 5g (10 ... 150 Hz / 10 cycles / axis / X, Y, Z) |
UL approval
Identification | UL/C-UL Listed UL 508 |
Identification | UL 121201 Class I, Division 2, Groups A, B, C, D, T4A |
ATEX
Identification | TÜV 22 ATEX 8874 X |
Identification | II 3G Ex ec IIC T4 Gc |
IECEx
Identification | IECEx TUR 22.0049X |
Identification | II 3G Ex ec IIC T4 Gc |
UKCA Ex (UKEX)
Identification | TÜV 22 UKEX 7109 X |
Identification | II 3G Ex ec IIC T4 Gc |
Corrosive gas test
Identification | ISA S71.04.2013 G3 Harsh Group A |
Standards and Regulations
Standards/specifications | EN 61000-6-2 |
Note | EMC – Immunity for industrial areas |
Standards/specifications | EN 61000-6-3 |
Note | EMC – Emission for residential, business and commercial properties and small operations |
Standards/specifications | EN 60068-2-78 |
Note | Environmental influences – Moisture and heat, constant |
Standards/specifications | EN 50178 |
Note | Equipping power installations with electronic equipment |
Standards/specifications | EN 60068-2-27 |
Note | Environmental influences – Shocks |
Standards/specifications | IEC 60079-7 |
Note | Explosive atmospheres – Part 7: Equipment protection by increased safety “e” |
Standards/specifications | IEC 60079-0 |
Note | Explosive atmospheres – Part 0: Equipment – General requirements |
Mounting
Mounting Type | pluggable onto CAPAROC CR… current rail |
Why Proax for Phoenix Contact 1344363?
Proax is an authorized distributor of Phoenix Contact 1344363 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |