SKU
MPN
CHARX PS-M2/3AC/1000DC/30KW
Weight
32 kg
Series CHARX-PS-M
CHARX PS-M2/3AC/1000DC/30KW - DC power module
CHARX power basic, Fast charging module for setting up DC charging stations, 19" rack mounting, input: 3-phase, output: 30 V DC...1000 V DC / 0 A...100 A
- Low installation costs with Plug and Play and efficient operation due to the high degree of efficiency
- Save space with the innovative design and high power density
- Scalable power for each charging point with the flexible assembly of system cabinets and connection of power modules
- The operation of large charging parks in the megawatt range is made possible by connecting multiple system cabinets together
Documents
Technical Specifications
Digital
Nominal Power Consumption | 31870 VA |
AC operation
Input voltage range | 3x 340 V AC ... 530 V AC |
Nominal input voltage range | 3x 400 V AC ... 480 V AC |
Input Frequency | 3x 50 Hz 60 Hz ±10 % |
Input Current | 3x 54 A (340 V AC) |
Input Current | 3x 46 A (400 V AC) |
Inrush current limitation | < 60 A |
Power factor (cos phi) | 0.99 |
Total distortion (THDi) | < 5 % (50% ... 100% output load) |
Insulation resistance | > 10 MΩ |
Supply system configuration | Star network (TN, TT, IT (PE)) |
Output data
Efficiency | > 95 % (POut >50%) |
Output voltage range | 30 V DC ... 1000 V DC |
Output current range | 0 A ... 100 A |
Output current residual ripple | ≤ 1 % |
Nominal power | 30 kW |
Power dissipation standby | < 14 W |
Protection against overvoltage at the output (OVP) | > 1040 V DC |
Derating | > 55 °C (3.2 A/K) |
Derating | > 55 °C (1 kW/K) |
Control deviation | < 0.5 % (Voltage deviation static load change 20% ... 100%) |
Control deviation | < 1 % (Current deviation Static load change 20 % ... 100 %) |
Control deviation | ± 0.2 % (Input voltage change ±20 %) |
Switch-on delay | < 8 s |
Overshoot behavior | ± 3 % (Switch-on procedure) |
Input
Designation | Input |
Identification | AC IN: L1 / L2 / L3 / PE |
Conductor connection
Connection Method | Push-lock connection |
rigid | 2.5 mm² ... 16 mm² |
rigid | 10 mm² (recommended) |
flexible | 2.5 mm² ... 25 mm² |
flexible | 10 mm² (recommended) |
rigid (AWG) | 13 ... 4 (Cu) |
rigid (AWG) | 8 (recommended) |
AWG | 7 |
Stripping length | 18 mm (rigid/flexible) |
Output
Designation | Output |
Identification | DC OUT: + / - |
Conductor connection
Connection Method | T-LOX knee lever connection |
rigid | 10 mm² ... 50 mm² |
rigid | 25 mm² (recommended) |
flexible | 16 mm² ... 50 mm² |
flexible | 25 mm² (recommended) |
rigid (AWG) | 8 ... 0 (Cu) |
rigid (AWG) | 4 (recommended) |
AWG | 3 |
Stripping length | 20 mm (10 mm² ... 25 mm² = 18 mm, 35 mm² ... 50 mm² = 20 mm) |
CAN-Bus
Interface | CAN bus |
Number of interfaces | 1 |
Connection Method | 2x RJ45 |
Supported protocols | CAN 2.0B |
Locking | Locking clip |
Transmission physics | wired |
Topology | Daisy Chain |
Transmission Speed | 125 kbps |
Transmission length | max. 20 m |
Termination resistor | 120 Ω (Terminating the end device) |
Number of power modules as CAN bus devices | max. 48 |
Electrical properties
Number of phases | 3 |
Electrical isolation between input and output | yes |
Insulation voltage input/output | 2121 V DC |
Insulation voltage input, output / housing | 2121 V DC |
Insulation voltage input, output/signal, communication | 4242 V DC |
Insulation voltage signal, communication/housing | 707 V DC |
Product properties
Product family | CHARX power basic |
MTBF (IEC 61709, SN 29500) | > 300000 h |
Service life | 90000 h (40°C, electrolytic capacitators) |
Service life | 70000 h (40 °C, fan) |
Hot PLUG connection | no |
Ventilation | no |
Internal fan | yes |
Flow Direction | from front to back |
Insulation characteristics
Protection class | I |
Pollution degree | 2 |
Item dimensions
Width | 483 mm |
Height | 134 mm |
Depth | 550 mm |
Rack unit | 3 U |
Mounting
Mounting Type | 19" rack mounting |
Material specifications
Housing Material | Zn-Al alloy |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -40 °C ... 70 °C |
Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Overtemperature protection (OTP) | > 75 °C |
Maximum altitude | ≤ 4000 m (Derating >2000 m: 10% / 1000 m) |
Permissible humidity (operation) | ≤ 95 % (non-condensing) |
Noise Level | < 60 dB (1 m) |
Overvoltage category
IEC 60664-1 | II |
Electric vehicle conductive charging system - Part 1: General requirements
Standard designation | Electric vehicle conductive charging system - Part 1: General requirements |
Standards/specifications | IEC 61851-1 |
Electric vehicle conductive charging system - Part 21-2: EMC requirements for off board electric vehicle charging systems
Standard designation | Electric vehicle conductive charging system - Part 21-2: EMC requirements for off board electric vehicle charging systems |
Standards/specifications | IEC 61851-21-2 (Class B) |
Electric vehicle conductive charging system – Part 23: DC electric vehicle charging station
Standard designation | Conductive charging systems for electric vehicles – Part 23: DC supply equipment for electric vehicles |
Standards/specifications | IEC 61851-23 |
Standard for Safety for Electric Vehicle (EV) Charging System Equipment
Standard designation | Standard for Safefy for Electric Vehicle (EV) Charging System Equipment |
Standards/specifications | ANSI/UL 2202 |
Approvals
Identification | IEC |
EMC data
EMC requirements for noise emission | EN 61000-6-3 |
EMC requirements for noise immunity | EN 61000-6-2 |
Why Proax for Phoenix Contact 1232243?
Proax is an authorized distributor of Phoenix Contact 1232243 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- CHARX control modular, AC charging controller, with Embedded Linux system, IEC 61851-1, ISO 15118, operating mode: Stand-Alone, Client, Server, interface: Ethernet (2x), CHARX control modular system bus, MICRO-USB type C, communication protocol: OCPP 1.6J, Modbus/TCP, MQTT, Connectable peripheral devices: Energy meter, RFID, DC residual current detection, DIN rail mounting
- CHARX control modular, AC charging controller, with Embedded Linux system, IEC 61851-1, ISO 15118, operating mode: Stand-Alone, Client, Server, interface: Ethernet (2x), Cellular communication (4G/2G), CHARX control modular system bus, MICRO-USB type C, communication protocol: OCPP 1.6J, Modbus/TCP, MQTT, Connectable peripheral devices: Energy meter, RFID, DC residual current detection, DIN rail mounting
- CHARX connect universal, DC CCS Typ 2, Vehicle charging inlet, up to 500 A in Boost mode, 200 A Permanent, 1000 V DC, Single wires, length: 2 m, locking actuator: 12 V, 4-pos., Front and rear mounting, M6, housing: black, for charging with direct current (DC), IEC 62196-2, IEC 62196-3, A protective cap is supplied as standard for the DC contacts.
- CHARX connect universal, AC/DC CCS Typ 2, Vehicle charging inlet, up to 250 A in Boost mode, 125 A Permanent, 1000 V DC, 32 A , 480 V AC, Single wires, length: 5 m, locking actuator: 12 V, 4-pos., Front and rear mounting, M6, housing: black, for charging with alternating current (AC) and with direct current (DC), IEC 62196-2, IEC 62196-3, A protective cap is supplied as standard for the DC and AC contacts.
- CHARX connect universal, AC/DC CCS Typ 2, Vehicle charging inlet, up to 500 A in Boost mode, 200 A Permanent, 1000 V DC, 32 A , 480 V AC, Single wires, length: 3 m, locking actuator: 12 V, 4-pos., Front and rear mounting, M6, housing: black, for charging with alternating current (AC) and with direct current (DC), IEC 62196-2, IEC 62196-3, A protective cap is supplied as standard for the DC and AC contacts.