SKU
MPN
NEARFI PD 2A ETH B
Weight
0.602 kg
This product is Not Cancellable/Not Returnable
Series NEARFI-PD
NEARFI PD 2A ETH B - Inductive coupler
NearFi base, contactless power and real-time Ethernet coupler, 50 W (US), 100 Mbps, range ≤10 mm, M12 screw connection, IP65, can be combined with NEARFI PD 2A ETH R. Incompatible with NEARFI 2200 (new)
- Contactless - and therefore no wear and no maintenance
- Protocol-independent, latency-free Ethernet real-time communication with 100 Mbps (full duplex)
- High power in a compact housing
- All-round visible diagnostics with light ring on the housing
- High degree of mounting freedom with flexible proximity options
- Plug and Play - as easy as a plug
- Degree of protection IP65
Documents
Technical Specifications
Product properties
Application | Ethernet |
Application | Power |
MTTF | 115 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
MTTF | 60 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) |
MTTF | 27 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) |
Insulation characteristics
Overvoltage category | II |
Pollution degree | 2 |
Electrical properties
Maximum power dissipation for nominal condition | 4.08 W |
Supply
Supply Voltage Range | 19 V DC ... 30 V DC |
Typical current consumption | 170 mA (without remote coupler, at 24 V DC, at 25°C) |
Typical current consumption | 480 mA (with remote coupler, without load, at 24 V DC, at 25°C) |
Max. current consumption | ≤ 3.6 A (with remote coupler, 2 A load, input voltage of 19 V DC) |
Inrush Current | ≤ 0.8 A (8 ms at 24 V DC, without remote coupler) |
Inrush Current | ≤ 4.5 A (6 ms at 24 V DC, with remote coupler, without load) |
Protective circuit | Transient protection, polarity protection |
Digital
Description of the input | Digital input |
Number of Inputs | 1 |
Voltage input signal | 19 V DC ... 30 V DC |
Switching level "1" signal | 19 V DC ... 30 V DC |
Signal
Output name | Digital output |
Number of Outputs | 1 |
Voltage output signal | ≤ 24 V DC |
Supply
Connection Method | M12 male, A-coded |
Data: Ethernet interface, 100Base-T(X) in accordance with IEEE 802.3
Transmission Speed | 100 Mbps |
Connection Method | M12 female, D-coded |
Note on the connection method | Auto negotiation and autocrossing, fast startup (FSU, <500 ms) |
Note on the connection method | Typical bit error rate ≤10-12 |
No. of channels | 1 |
Transmission length | 100 m (shielded twisted pair) |
Transmission medium | Copper |
Protocols Supported | Protocol transparent: PROFINET, PROFINET IRT, PROFIsafe, EtherCAT®, Modbus/TCP, Powerlink, TSN, etc. |
Inductive: Power transmission
Switch-on time | < 450 ms (ETH Full Duplex operating mode) |
Range | min. 0 mm |
Range | ≤ 10 mm (at 55°C) |
Range | ≤ 12 mm (at 25 °C) |
Center offset | ± 5 mm |
Wireless modules that can be connected | 1 (Remote coupler) |
Frequency Range | 100 kHz ... 148.5 kHz (Power transmission) |
Test field strength | ~ 1.95 µA/m (within 10 m distance) |
Wireless
Wireless modules that can be connected | 1 (Remote coupler) |
Frequency | 60 GHz |
Frequency Range | 57 GHz ... 64 GHz (Data transmission) |
Transmission power | < 10 mW (EIRP) |
Delay time | ≤ 1 µs (typical) |
Dimensions
Width | 80 mm |
Height | 86 mm |
Depth | 39 mm |
Material specifications
Color (Housing) | black (RAL 9005) |
Material (Enclosure) | PBT |
Material (Enclosure) | Die-cast zinc |
Flammability rating according to UL 94 | V0 |
Cable/line
Other resistance | Resistant to welding splashes |
Mechanical tests
Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-6 | : 5 g per spatial direction, 10 Hz ... 150 Hz, amplitude ±0.34 mm |
Shock in accordance with EN 60068-2-27/IEC 60068-2-27 | : 30 g, 11 ms duration, half-sine shock pulse, three shocks per spatial direction |
Continuous shock in accordance with EN 60068-2-27/IEC 60068-2-27 | : 10 g, 16 ms duration, half-sine shock pulse, 1,000 shocks per spatial direction |
Ambient conditions
Degree of Protection | IP65 (Manufacturer's declaration) |
Impact strength | IK06 |
Ambient Temperature (Operation) | -20 °C ... 55 °C (observe derating) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | 2000 m |
Permissible humidity (operation) | 10 % ... 95 % |
Permissible humidity (storage/transport) | 10 % ... 95 % |
Air pressure (operation) | 80 kPa ... 108 kPa (up to 2000 m above sea level) |
Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above sea level) |
CE
Certificate | CE-compliant |
Wireless approval, Europe
Note | RED 2014/53/EU |
UL, USA
Identification | UL 61010 Recognized |
Identification | UL 61010-2-201, 2nd Edition |
Identification | UL 61010-1, 3rd Edition |
Certificate | E238705 |
UL, Canada
Identification | cUL 61010 Recognized |
Identification | CSA C22.2 NO. 61010-2-201:18, 2nd Edition |
Identification | CSA C22.2 NO. 61010-1, 3rd Edition |
Certificate | E238705 |
Wireless approval USA, FCC
Certificate | YG3PD2AETHB |
Wireless approval Canada, IC
Certificate | 4720B-PD2AETHB |
Wireless approval Japan, MIC
Identification | 006-001058 |
KC approval for South Korea
Certificate | R-R-PCK-1234232 |
CC-Link IE TSN
Identification | Class A |
EMC data
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Conducted noise emission | EN 55032 Class A, industrial applications |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 4 kV (Test Level 2) |
Discharge in air | ± 8 kV (Test Level 3) |
Comments | Criterion B |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 80 MHz ... 1 GHz (Test Level 3) |
Field intensity | 10 V/m |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | ± 2 kV (Test Level 3 - asymmetrical) |
Output | ± 2 kV (Test Level 3 - asymmetrical) |
Signal | ± 2 kV (Test Level 3 - asymmetrical) |
Comments | Criterion B |
Surge current load (surge)
Standards/regulations | EN 61000-4-5 |
Input | ± 0.5 kV (Test Level 1 - symmetrical) |
Input | ± 1 kV (Test Level 2 - asymmetrical) |
Output | ± 1 kV (Test Level 2 - asymmetrical) |
Signal | ± 1 kV (Test Level 2 - asymmetrical) |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Frequency Range | 0.15 MHz ... 80 MHz (Test Level 3 - asymmetrical) |
Comments | Criterion A |
Voltage | 10 V (80% amplitude modulation with 1 kHz) |
Emitted interference
Standards/regulations | EN 55016-2-3 |
Comments | Class A, industrial applications |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Standards and Regulations
Free from substances that could impair the application of coating | VDMA 24364:2018-05 |
Other resistance | Resistant to welding splashes |
Standards/regulations | EN 60204-1 (PELV) |
Standard designation | Protective extra-low voltage |
Mounting
Mounting Type | Panel mounting |
Assembly note | Observe derating |
Mounting Position | any |
Why Proax for Phoenix Contact 1234224?
Proax is an authorized distributor of Phoenix Contact 1234224 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended