1234229
SKU
PHX1234229
MPN
NEARFI P 2A R
Weight
0.566 kg
This product is Not Cancellable/Not Returnable
Series NEARFI-P
NEARFI P 2A R - Inductive coupler
NearFi remote, contactless power coupler, 50 W (US), range ≤10 mm, M12 screw connection, IP65, can be combined with NEARFI P 2A B. Incompatible with NEARFI 200 (new)
- Contactless - and therefore no wear and no maintenance
- High power in a compact housing
- All-round visible diagnostics with light ring on the housing
- High degree of mounting freedom with flexible proximity options
- Plug and Play - as easy as a plug
- Degree of protection IP65
Documents
Technical Specifications
Product properties
| Application | Power |
| MTTF | 331 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
| MTTF | 196 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) |
| MTTF | 98 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) |
Insulation characteristics
| Overvoltage category | II |
| Pollution degree | 2 |
Supply
| Protective circuit | Short-circuit/overload protection |
| Connection Method | M12 female, A-coded |
Inductive: Power transmission
| Switch-on time | < 50 ms |
| Range | min. 0 mm |
| Range | ≤ 10 mm (at 60 °C) |
| Range | ≤ 12 mm (at 25 °C) |
| Center offset | ± 10 mm |
| Wireless modules that can be connected | 1 (Base coupler) |
| Frequency Range | 100 kHz ... 148.5 kHz (Power transmission) |
Dimensions
| Width | 80 mm |
| Height | 86 mm |
| Depth | 39 mm |
Material specifications
| Color (Housing) | black (RAL 9005) |
| Material (Enclosure) | PBT |
| Material (Enclosure) | Die-cast zinc |
| Flammability rating according to UL 94 | V0 |
Cable/line
| Other resistance | Resistant to welding splashes |
Mechanical tests
| Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-6 | : 5 g per spatial direction, 10 Hz ... 150 Hz, amplitude ±0.34 mm |
| Shock in accordance with EN 60068-2-27/IEC 60068-2-27 | : 30 g, 11 ms duration, half-sine shock pulse, three shocks per spatial direction |
| Continuous shock in accordance with EN 60068-2-27/IEC 60068-2-27 | : 10 g, 16 ms duration, half-sine shock pulse, 1,000 shocks per spatial direction |
Ambient conditions
| Degree of Protection | IP65 (Manufacturer's declaration) |
| Impact strength | IK06 |
| Ambient Temperature (Operation) | -20 °C ... 60 °C (observe derating) |
| Ambient Temperature (Operation) | -20 °C ... 40 °C (in accordance with UL, observe derating) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Altitude | 2000 m |
| Permissible humidity (operation) | 10 % ... 95 % |
| Permissible humidity (storage/transport) | 10 % ... 95 % |
| Air pressure (operation) | 80 kPa ... 108 kPa (up to 2000 m above sea level) |
| Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above sea level) |
CE
| Certificate | CE-compliant |
Wireless approval, Europe
| Note | RED 2014/53/EU |
UL, USA
| Identification | UL 61010 Listed |
| Identification | UL 61010-2-201, 2nd Edition |
| Identification | UL 61010-1, 3rd Edition |
| Certificate | E238705 |
UL, Canada
| Identification | cUL 61010 Listed |
| Identification | CSA C22.2 NO. 61010-2-201:18, 2nd Edition |
| Identification | CSA C22.2 NO. 61010-1, 3rd Edition |
| Certificate | E238705 |
Wireless approval USA, FCC
| Certificate | YG3P2AR |
Wireless approval Canada, IC
| Certificate | 4720B-P2AR |
KC approval for South Korea
| Certificate | R-R-PCK-1234232 |
EMC data
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Conducted noise emission | EN 55032 Class A, industrial applications |
Electrostatic discharge
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | ± 4 kV (Test Level 2) |
| Discharge in air | ± 8 kV (Test Level 3) |
| Comments | Criterion B |
Electromagnetic HF field
| Standards/regulations | EN 61000-4-3 |
| Frequency Range | 80 MHz ... 1 GHz (Test Level 3) |
| Field intensity | 10 V/m |
| Comments | Criterion A |
Fast transients (burst)
| Standards/regulations | EN 61000-4-4 |
| Input | ± 2 kV (Test Level 3 - asymmetrical) |
| Output | ± 2 kV (Test Level 3 - asymmetrical) |
| Signal | ± 2 kV (Test Level 3 - asymmetrical) |
| Comments | Criterion B |
Surge current load (surge)
| Standards/regulations | EN 61000-4-5 |
| Input | ± 0.5 kV (Test Level 1 - symmetrical) |
| Input | ± 1 kV (Test Level 2 - asymmetrical) |
| Output | ± 1 kV (Test Level 2 - asymmetrical) |
| Signal | ± 1 kV (Test Level 2 - asymmetrical) |
| Comments | Criterion B |
Conducted interference
| Standards/regulations | EN 61000-4-6 |
| Frequency Range | 0.15 MHz ... 80 MHz (Test Level 3 - asymmetrical) |
| Comments | Criterion A |
| Voltage | 10 V (80% amplitude modulation with 1 kHz) |
Emitted interference
| Standards/regulations | EN 55016-2-3 |
| Comments | Class A, industrial applications |
Criteria
| Criterion A | Normal operating behavior within the specified limits. |
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Standards and Regulations
| Free from substances that could impair the application of coating | VDMA 24364:2018-05 |
| Other resistance | Resistant to welding splashes |
| Standards/regulations | EN 60204-1 (PELV) |
| Standard designation | Protective extra-low voltage |
Mounting
| Mounting Type | Panel mounting |
| Assembly note | Observe derating |
| Mounting Position | any |
Why Proax for Phoenix Contact 1234229?
Proax is an authorized distributor of Phoenix Contact 1234229 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended