Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
QUINT4-SYS-PS/1AC/24DC/2.5/SC
Weight
0.36 kg

QUINT4-SYS-PS/1AC/24DC/2.5/SC - Power supply unit

Primary-switched power supply, QUINT POWER, screw connection, DIN rail mounting, supply of devices possible via the TBUS DIN rail connector, protective coating, input: single-phase, output: 24 V DC/2.5 A

  • Also for operation in potentially explosive areas (zone 2)
  • Optionally for supplying devices via the TBUS DIN rail connector
  • Preventive function monitoring indicates critical operating states before errors occur
  • Starting of heavy loads with dynamic boost
  • High efficiency and long service life, with low power dissipation and low heating
Technical Specifications

AC operation

Nominal input voltage range100 V AC ... 240 V AC
Input voltage range100 V AC ... 240 V AC -15 % ... +10 %
Electric strength, max.300 V AC 30 s
Typical national grid voltage120 V AC
Typical national grid voltage230 V AC
Voltage type of supply voltageAC/DC
Inrush Currenttyp. 10 A (at 25 °C)
Inrush current integral (I2t)typ. 0.1 A2s
Inrush current limitation10 A
Frequency range (fN)50 Hz ... 60 Hz ±10 %
Frequency range (fN)16.7 Hz (acc. to EN 50163)
Mains buffering timetyp. 31 ms (120 V AC)
Mains buffering timetyp. 31 ms (230 V AC)
Current consumption0.85 A (100 V AC)
Current consumption0.7 A (120 V AC)
Current consumption0.39 A (230 V AC)
Current consumption0.37 A (240 V AC)
Protective circuitTransient surge protection; Varistor
Typical response time500 ms
Input fuse4 A (slow-blow, internal)
Recommended breaker for input protection6 A ... 16 A (Characteristic B, C, D, K or comparable)
Discharge current to PE< 0.25 mA (264 V AC, 60 Hz)
Discharge current to PE< 0.22 mA

DC operation

Input voltage range110 V DC ... 250 V DC -20 % ... +40 %
Voltage type of supply voltageAC/DC
Current consumption0.75 A (110 V DC)
Current consumption0.33 A (250 V DC)

Output data

Efficiencytyp. 93 % (120 V AC)
Efficiencytyp. 94 % (230 V AC)
Nominal Output Voltage24 V DC
Setting range of the output voltage (USet)24 V DC ... 27 V DC (constant capacity)
Nominal output current (IN)2.5 A
Static Boost (IStat.Boost)3.125 A (≤ 40°C)
Dynamic Boost (IDyn.Boost)4 A (≤ 60 °C (on ≤ 5 s/off ≥ 5 s))
Feedback voltage resistance≤ 32 V DC
Protection against overvoltage at the output (OVP)≤ 30 V DC ±2 %
Control deviation< 0.5 % (Static load change 10 % ... 90 %)
Control deviation< 2 % (Dynamic load change 10 % ... 90 %, (10 Hz))
Control deviation< 0.25 % (change in input voltage ±10 %)
Residual ripple< 40 mVPP (with nominal values)
Short-circuit-proofyes
No-load proofyes
Output Power60 W
Output Power75 W
Output Power96 W
Maximum no-load power dissipation< 1 W (120 V AC)
Maximum no-load power dissipation< 1 W (230 V AC)
Power loss nominal load max.< 5 W (120 V AC)
Power loss nominal load max.< 4 W (230 V AC)
Crest factortyp. 1.8 (120 V AC)
Crest factortyp. 1.84 (230 V AC)
Rise time50 ms (UOut = 10 % ... 90 %)

Signal (configurable)

Digital0 V DC 24 V DC 30 mA
Default24 V DC 30 mA 24 V DC for UOut > 0.9 x USet

Input

Connection MethodScrew connection
Conductor cross section, rigid min.0.14 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.14 mm²
Conductor cross section flexible max.2.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.0.25 mm²
Single conductor/terminal point, stranded, with ferrule, max.2.5 mm²
Conductor cross section AWG min.26
Conductor cross section AWG max.14
Stripping length8 mm
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Output

Connection MethodScrew connection
Conductor cross section, rigid min.0.14 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.14 mm²
Conductor cross section flexible max.2.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.0.25 mm²
Single conductor/terminal point, stranded, with ferrule, max.2.5 mm²
Conductor cross section AWG min.26
Conductor cross section AWG max.14
Stripping length8 mm
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Signal

Connection MethodScrew connection
Conductor cross section, rigid min.0.14 mm²
Conductor cross section, rigid max.2.5 mm²
Conductor cross section flexible min.0.14 mm²
Conductor cross section flexible max.2.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.0.25 mm²
Single conductor/terminal point, stranded, with ferrule, max.2.5 mm²
Conductor cross section AWG min.26
Conductor cross section AWG max.14
Stripping length8 mm
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

Signaling

Types of signalingLED

Signal output

POut> PThr (LED lights up yellow, output power > PThr, depending on the rotary selector switch setting)
UOut> 0.9 x USet (LED lights up green)
UOut< 0.9 x USet (LED flashes green)

Electrical properties

Number of phases1.00
Insulation voltage input/output4 kV AC (type test)
Insulation voltage input/output3 kV AC (routine test)
Switching frequency90.00 kHz ... 110.00 kHz (Auxiliary converter stage)
Switching frequency50.00 kHz ... 195.00 kHz (Main converter stage)
Switching frequency60.00 kHz ... 360.00 kHz (PFC stage)

Product properties

Product familyQUINT POWER
MTBF (IEC 61709, SN 29500)> 2000000 h (25 °C)
MTBF (IEC 61709, SN 29500)> 1161000 h (40 °C)
MTBF (IEC 61709, SN 29500)> 514000 h (60 °C)
Environmental protection directiveRoHS Directive 2011/65/EU
Environmental protection directiveWEEE
Environmental protection directiveReach

Insulation characteristics

Protection classII
Degree of pollution2

Life expectancy (electrolytic capacitors)

Current2.5 A
Temperature40 °C
Time323000 h
Additional text120 V AC
Current2.5 A
Temperature40 °C
Time346000 h
Additional text230 V AC
Current2.5 A
Temperature25 °C
Time915000 h
Additional text120 V AC
Current2.5 A
Temperature25 °C
Time980000 h
Additional text230 V AC

Dimensions

Width40 mm
Height99 mm
Depth114 mm

Installation dimensions

Installation distance right/left (active)15 mm / 15 mm (POut ≥50% )
Installation distance right/left (passive)5 mm / 5 mm (POut ≥50% )
Installation distance right/left (active, passive)0 mm / 0 mm (POut ≤50 %)
Installation distance top/bottom (active)30 mm / 30 mm (POut ≥50% )
Installation distance top/bottom (passive)30 mm / 30 mm (POut ≥50% )
Installation distance top/bottom (active, passive)30 mm / 30 mm (POut ≤50 %)

Mounting

Mounting TypeDIN rail mounting
With protective coatingNo

Material specifications

Flammability rating according to UL 94 (housing / terminal blocks)V0
Housing MaterialPlastic
Type of housingPolycarbonate
Hood versionPolycarbonate

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (start-up type tested)-40 °C
Maximum altitude≤ 5000 m (> 2000 m, observe derating)
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (Operation)5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)

Standards and Regulations

Rail applicationsEN 50121-3-2
Rail applicationsEN 50121-4
Rail applicationsEN 50121-5
Rail applicationsIEC 62236-3-2
Rail applicationsIEC 62236-4
Rail applicationsIEC 62236-5
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard – Safety extra-low voltageIEC 61010-1 (SELV)
Standard – Safety extra-low voltageIEC 61010-2-201 (PELV)
Standard - Safe isolationIEC 61558-2-16
Standard - Safe isolationIEC 61010-2-201
Standard - safety for equipment for measurement, control, and laboratory useIEC 61010-1
Standard - safety for equipment for measurement, control, and laboratory useIEC 61010-2-201 (SELV)
Standard - Safety of transformersEN 61558-2-16

Overvoltage category

EN 61010-1II (≤ 5000 m)
EN 62477-1III (≤ 2000 m)

ATEX

IdentificationUL 21 ATEX 2597 X
Identification II 3 G   Ex ec nC IIC T4 Gc

IECEx

IdentificationIECEx ULD 21.0023X
IdentificationEx ec nC IIC T4 Gc

UKEX

IdentificationUL21UKEX2208X

UL

IdentificationUL Listed UL 61010-1
IdentificationUL Listed UL 61010-2-201
IdentificationUL 1310 Class 2 Power Units
IdentificationANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location)

SIQ

IdentificationCB scheme (IEC 61010-1, IEC 61010-2-201)

EMC data

Interference emissionInterference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial)
Noise immunityImmunity in accordance with EN 61000-6-1 (residential), EN 61000-6-2 (industrial), and EN 61000-6-5 (power station equipment zone), IEC/EN 61850-3 (power supply)
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
EMC requirements, power plantIEC 61850-3
EMC requirements, power plantEN 61000-6-5
Conducted noise emissionEN 55016
Conducted noise emissionEN 61000-6-3 (Class B)
Noise emissionAdditional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply)
Noise emissionEN 55016
Noise emissionEN 61000-6-3 (Class B)

Harmonic currents

Standards/regulationsEN 61000-3-2
Standards/regulationsEN 61000-3-2 (Class A)
Frequency Range0 kHz ... 2 kHz

Flicker

Standards/regulationsEN 61000-3-3
Frequency Range0 kHz ... 2 kHz

Electrostatic discharge

Standards/regulationsEN 61000-4-2
Contact discharge8 kV (Test Level 4)
Discharge in air15 kV (Test Level 4)
CommentsCriterion A

Electromagnetic HF field

Standards/regulationsEN 61000-4-3
Frequency Range80 MHz ... 1 GHz
Test field strength20 V/m (Test Level X)
Frequency Range1 GHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A

Fast transients (burst)

Standards/regulationsEN 61000-4-4
Input4 kV (Test Level 4 - asymmetrical)
Output4 kV (Test Level X - asymmetrical)
Signal4 kV (Test Level X - asymmetrical)
CommentsCriterion A

Surge voltage load (surge)

Standards/regulationsEN 61000-4-5
Input1 kV (Test Level 3 - symmetrical)
Input2 kV (Test Level 3 - asymmetrical)
Output0.5 kV (Test Level 2 - symmetrical)
Output0.5 kV (Test Level 1 - asymmetrical)
CommentsCriterion B

Conducted interference

Standards/regulationsEN 61000-4-6
I/O/Sasymmetrical
Frequency Range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)

Power frequency magnetic field

Standards/regulationsEN 61000-4-8
Frequency16.67 Hz
Frequency50 Hz
Frequency60 Hz
Test field strength100 A/m
Additional text60 s
CommentsCriterion A
Frequency50 Hz
Frequency60 Hz
Frequency Range50 Hz ... 60 Hz
Test field strength1 kA/m
Additional text3 s
Frequency0 Hz
Test field strength300 A/m
Additional textDC, 60 s

Voltage dips

Standards/regulationsEN 61000-4-11
Voltage100 V AC
Frequency60 Hz
Voltage dip70 %
Number of periods0.5 / 1 / 30 periods
Additional textTest Level 2
CommentsCriterion A
Voltage dip40 %
Number of periods5 / 10 / 50 periods
Additional textTest Level 2
CommentsCriterion B
Voltage dip0 %
Number of periods0.5 / 1 / 5 / 50 periods
Additional textTest Level 2
CommentsCriterion B

Pulse-shape magnetic field

Standards/regulationsEN 61000-4-9
Test field strength1000 A/m
CommentsCriterion A

Attenuated sinusoidal oscillations (ring wave)

Standards/regulationsEN 61000-4-12
Input2 kV (symmetrical)
Input4 kV (asymmetrical)
CommentsCriterion A

Asymmetrical conducted disturbance variables

Standards/regulationsEN 61000-4-16
Test level 116.67 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
Voltage30 V (10 s)
Test level 216.67 Hz 50 Hz 60 Hz (Test Level 2)
Voltage300 V (1 s)
CommentsCriterion A

Attenuated oscillating wave

Standards/regulationsEN 61000-4-18
Voltage1 kV (symmetrical)
Voltage2.5 kV (asymmetrical)
Voltage1 kV (symmetrical)
CommentsCriterion A

Criteria

Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Criterion CTemporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.

Why Proax for Phoenix Contact 2904614?

Proax is an authorized distributor of Phoenix Contact 2904614 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability