MPN
IB IL AO 2/UI-XC-PAC
Weight
0.091 kg
Series IB-IL-AO

IB IL AO 2/UI-XC-PAC - Analog module

Inline, Analog output terminal, Analog outputs: 2, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 500 kbps, Extreme conditions version, degree of protection: IP20, including Inline connector and labeling field

  • 2 analog output channels
  • Connection of actuators in 2-conductor technology
  • Current ranges: 0 mA ... 20 mA, 4 mA ... 20 mA, ±20 mA
  • Voltage ranges: 0 V ... 10 V, ±10 V
  • Can be used under extreme ambient conditions
  • Extended temperature range of -40 °C ... +70 °C (see “Tested successfully: use under extreme ambient conditions” in the data sheet)
  • Coated PCBs
Technical Specifications

Dimensions

Width12.2 mm
Height119.8 mm
Depth71.5 mm
Note on dimensionsHousing dimensions

Inline local bus

Number of interfaces2
Connection MethodInline data jumper
Transmission Speed500 kbps
Transmission physicsCopper

Module

ID code (dec.)91
ID code (hex)5B
Length code (hex)04
Length code (dec)04
Process data channel64 bit
Input address area8 Byte
Output address area8 Byte
Register length64 bit
Required parameter data 10 Byte
Required configuration data 5 Byte

Analog:

Output nameAnalog outputs
Connection technology2-conductor
Note regarding the connection technologyshielded
Number of Outputs2
D/A conversion timetyp. 10 µs
D/A converter resolution12 bit
Protective circuitShort-circuit and overload protection; Electronic
Protective circuitTransient protection; Suppressor diode
Data formatsIB IL, S7-compatible
Representation of output values12 bits (11 bits + sign bit)
Process data updatebus-synchronous
Current Output Signal0 mA ... 20 mA
Current Output Signal4 mA ... 20 mA
Current Output Signal-20 mA ... 20 mA
Load/Output Load Current Output≤ 450 Ω
Voltage output signal0 V ... 10 V
Voltage output signal-10 V ... 10 V
Load/output load voltage output> 1 kΩ
Permissible cable lengthmax. 250 m (The specifications refer to nominal operation after complying with installation instructions. The specifications refer to the following reference cable type: Shielded power station cable: LiYCY; 2 x 2 x 0,5 mm²; VDE0812)

Product properties

Product familyInline
Typemodular
Scope of deliveryincluding Inline connector and labeling field
Special PropertiesExtreme conditions version
Diagnostics messagesFailure of the internal I/O supply I/O error message sent to the bus coupler
Diagnostics messagesI/O supply failure Message in the diagnostic code (in the IB IL format)
Diagnostics messagesShort circuit/overload of the outputs Message in the diagnostic code (in the IB IL format)
Diagnostics messagesConfiguration invalid Message in the diagnostic code (in the IB IL format)

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Potentials

Power consumptiontyp. 1.32 W (Nominal voltage load (UOUT1/2 = 10 V, RL = 1 kΩ))
Power consumptiontyp. 1.97 W (Nominal current load (IOUT1/2 = 20 mA, RL = 0 Ω))

Potentials: Communications power (UL)

Supply Voltage7.5 V DC (via voltage jumper)
Current drawmax. 65 mA
Current drawtyp. 55 mA

Potentials: Supply of analog modules (UANA)

Supply Voltage24 V DC (via voltage jumper)
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 75 mA (Nominal current load (IOUT1/2 = 20 mA, RL = 0 Ω))
Current drawmax. 30 mA (No-load)
Current drawtyp. 38 mA (Nominal voltage load (UOUT1/2 = 10 V, RL = 1 kΩ))
Current drawmax. 45 mA (Nominal voltage load (UOUT1/2 = 10 V, RL = 1 kΩ))
Current drawtyp. 65 mA (Nominal current load (IOUT1/2 = 20 mA, RL = 0 Ω))
Current drawtyp. 24 mA (No-load)

Electrical isolation/isolation of the voltage ranges

Test voltage: 7.5 V supply (bus logics)/24 V analog supply (analog I/O)500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logic)/functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V analog supply (analog I/O)/functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameInline connector

Conductor connection

Connection MethodSpring-cage connection
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Inline connector

Connection MethodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 55 °C (Standard)
Ambient Temperature (Operation)-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2701389?

Proax is an authorized distributor of Phoenix Contact 2701389 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability