Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2861467
Weight
0.094 kg
This product is Not Cancellable/Not Returnable
Series IB-IL-AO

IB IL AO 2/U/BP-PAC - Analog module

Inline, Analog output terminal, Analog outputs: 2, 0 V ... 10 V, -10 V ... 10 V, connection technology: 2-conductor, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connector and labeling field

  • 2 analog output channels
  • Connection of actuators in 2-conductor technology
  • Voltage ranges: 0 V ... 10 V, ±10 V
  • Output values can be represented in two different formats
  • Behavior of the outputs in the event of an error can be configured
  • Process data update including conversion time of the digital/analog converter < 1 ms
  • Very good output driver characteristics, making it also suitable for long actuator cables
Technical Specifications

Dimensions

Width12.2 mm
Height136.8 mm
Depth71.5 mm

Utilization restriction

CCCex noteUse in potentially explosive areas is not permitted in China.

Inline local bus

Number of interfaces2
Connection MethodInline data jumper
Transmission Speed500 kbps
Transmission physicsCopper

Module

ID code (dec.)91
ID code (hex)5B
Length code (hex)02
Length code (dec)02
Process data channel32 bit
Input address area4 Byte
Output address area4 Byte
Register length32 bit
Required parameter data 6 Byte
Required configuration data 5 Byte

Analog:

Output nameAnalog outputs
Output descriptionSingle-ended
Connection technology2-conductor
Note regarding the connection technologyshielded
Number of Outputs2
D/A conversion time< 100 ns
Protective circuitTransient protection of outputs
Data formatsIB IL, IB ST
Representation of output values16 bits (15 bits + sign)
DAC resolution13 bit
Process data update< 1 ms
Voltage output signal0 V ... 10 V
Voltage output signal-10 V ... 10 V
Load/output load voltage output> 2 kΩ
Permissible cable lengthmax. 500 m (The specifications refer to nominal operation after complying with installation instructions. The specifications refer to the following reference cable type: Shielded power station cable: LiYCY; 2 x 2 x 0,5 mm²; VDE0812)

Product properties

Product familyInline
Typemodular
Scope of deliveryincluding Inline connector and labeling field
Diagnostics messagesFailure of or insufficient communications power UL I/O error message sent to the bus coupler

Insulation characteristics

Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical properties

Maximum power dissipation for nominal condition1.8 W

Potentials

Power consumptiontyp. 0.68 W (No-load)
Power consumptiontyp. 0.85 W (Full load (RL = 2 kΩ))

Potentials: Communications power (UL)

Supply Voltage7.5 V DC (via voltage jumper)
Current drawmax. 40 mA
Current drawtyp. 33 mA

Potentials: Supply of analog modules (UANA)

Supply Voltage24 V DC (via voltage jumper)
Supply Voltage Range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 35 mA (Full load (RL = 2 kΩ))
Current drawmax. 28 mA (No-load)
Current drawtyp. 25 mA (Full load (RL = 2 kΩ))
Current drawtyp. 18 mA (No-load)

Electrical isolation/isolation of the voltage ranges

Test voltage: 7.5 V supply (bus logic), 24 V supply UANA / I/O500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logic), 24 V supply UANA / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.

Connection technology

Connection nameInline connector

Conductor connection

Connection MethodSpring-cage connection
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Inline connector

Connection MethodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Ambient conditions

Ambient Temperature (Operation)-25 °C ... 55 °C
Degree of ProtectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)

Standards and Regulations

Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact IB IL AO 2/U/BP-PAC?

Proax is an authorized distributor of Phoenix Contact IB IL AO 2/U/BP-PAC and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesIBILAO2UBPPAC
Pack Size1
Recommended

Available for order