Official Distributor
SKU
MPN
SAC-5PY-M/2X10,0-920
Weight
1.153 kg
Series SAC-5PY
Bus system cable - SAC-5PY-M/2X10,0-920
Bus system cable, CANopen®, DeviceNet™, 5-position, PUR halogen-free, violet RAL 4001, shielded, Plug straight M12 SPEEDCON, coding: A, on free cable end and free cable end, cable length: 10 m, Connector unshielded, Shield connected to pin 1
Technical Specifications
Dimensions
Length of Cable | 10 m |
Center distance | 21 mm |
Ambient conditions
Ambient Temperature (Operation) | -25 °C ... 90 °C (Plug / socket) |
Ambient Temperature (Operation) | -25 °C ... 90 °C (Plug / socket) |
Degree of Protection | IP65 |
Degree of Protection | IP67 |
General
Rated current at 40°C | 4 A |
Rated voltage | 48 V AC |
Rated voltage | 60 V DC |
Number of Positions | 5 |
Color handle area | black |
Insulation resistance | ≥ 100 MΩ |
Coding | A - standard |
Standards/regulations | M12 connector IEC 61076-2-101 |
Signal type/category | CANopen® |
Signal type/category | DeviceNet™ |
Status display | No |
Overvoltage category | II |
Degree of pollution | 3 |
Material
Flammability rating according to UL 94 | HB |
Contact Material | CuSn |
Contact surface material | Ni/Au |
Contact carrier material | TPU GF |
Material of grip body | TPU, hardly inflammable, self-extinguishing |
Material, knurls | Zinc die-cast, nickel-plated |
Pin assignment
Contact | Color (signal designation) | Contact (optional) | 1 (Distributor) = SR (shield) |
Contact | Color (signal designation) | Contact (optional) | 2 (Distributor) = RD (V+) |
Contact | Color (signal designation) | Contact (optional) | 3 (Distributor) = BK (V-) |
Contact | Color (signal designation) | Contact (optional) | 4 (Distributor) = WH (CAN_H) |
Contact | Color (signal designation) | Contact (optional) | 5 (Distributor) = BU (CAN_L) |
Standards and Regulations
Standards/specifications | M12 connector IEC 61076-2-101 |
Cable
Cable Type | CANopen®/DeviceNet™, PUR, violet |
Cable type (abbreviation) | 920 |
UL AWM style | 21198 (80°C/300 V) |
Cable structure | 2xAWG24/19+2xAWG22/19 |
Conductor Cross Section | 2x 0.25 mm² (Data cable) |
Conductor Cross Section | 2x 0.34 mm² (Power supply) |
Conductor Cross Section | 1x 0.34 mm² (Drain wire) |
AWG Signal Line | 24 |
AWG Power Supply | 22 |
Conductor structure signal line | 19x 0.13 mm |
Conductor structure, voltage supply | 19x 0.15 mm |
Core diameter including insulation | 1.95 mm ±0.05 mm (Data cable) |
Core diameter including insulation | 1.4 mm ±0.05 mm (Power supply) |
Wire colors | Red-black, blue-white |
Twisted pairs | 2 cores to the pair |
Type of pair shielding | Plastic-coated aluminum foil, aluminum side outside |
Overall twist | 2 pairs around a drain wire in the center to the core |
Shielding | Tinned copper braided shield |
Optical shield covering | 80 % |
External cable diameter D | 6.7 mm ±0.3 mm |
Minimum bending radius, fixed installation | 5 x D |
Minimum bending radius, flexible installation | 10 x D |
Number of bending cycles | 5000000 |
Bending Radius | 70 mm |
Minimum bending radius, drag chain applications | 10 x D |
Traversing path | 4.5 m |
Traversing rate | 3 m/s |
Acceleration | 3 m/s² |
Ambient Temperature (Operation) | -20 °C ... 60 °C |
Cable weight | 90 kg/km |
External sheath, color | violet RAL 4001 |
Outer sheath, material | PUR |
Material conductor insulation | Foamed PE (Data cable) |
Material conductor insulation | PE (Power supply) |
Conductor material | Tin-plated Cu litz wires |
Insulation resistance | ≥ 5 GΩ*km (Data cable) |
Insulation resistance | ≥ 5 GΩ*km (Power supply) |
Loop resistance | ≤ 181.80 Ω/km (Data cable) |
Loop resistance | ≤ 114.80 Ω/km (Power supply) |
Cable capacity | nom. 40 nF/km (Data cable) |
Wave impedance | 120 Ω ±10 % (with 1 MHz) |
Attenuation | ≤ 22.9 dB/km (with 1 MHz) |
Attenuation | ≤ 16.4 dB/km (At 500 kHz) |
Attenuation | ≤ 9.5 dB/km (At 125 kHz) |
Nominal voltage, cable | ≤ 300 V (Peak value, not for high-power applications) |
Test voltage Core/Core | 2000 V (50 Hz, 1 min.) |
Test voltage Core/Shield | 2000 V (50 Hz, 1 min.) |
Other resistance | Low adhesion |
Flame resistance | UL 1581, Section 1060 and UL 2556, Section 9.3 (FT1) |
Flame resistance | UL 1581, Section 1100 and UL 2556, Section 9.1 (HFT/FT2) |
Flame resistance | IEC 60332-1-2 |
Flame resistance | in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01) |
Halogen-free | in accordance with DIN VDE 0472 part 815 |
Halogen-free | according to IEC 60754-1 |
Ambient Temperature (Operation) | -40 °C ... 80 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -30 °C ... 70 °C (Cable, flexible installation) |
Ambient Temperature (Operation) | -20 °C ... 60 °C (for installation) |
Ambient Temperature (Operation) | -20 °C ... 60 °C (cable, drag chain applications) |
Environmental Product Compliance
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 50 years |
China RoHS | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Accessories
Why Proax for Phoenix Contact 1436107?
Proax is an authorized distributor of Phoenix Contact 1436107 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended
- 1436068 - Bus system cable, CANopen®, DeviceNet™, 5-position, PUR halogen-free, red lilac RAL 4001, shielded (Tinned copper braided shield), Socket straight M12 SPEEDCON, coding: A, on Socket straight M12 SPEEDCON, coding: A and Plug straight M12 SPEEDCON, coding: A, cable length: 10 m, all connectors unshielded, Shield connected to pin 1
- 1436071 - Bus system cable, CANopen®, DeviceNet™, 5-position, PUR halogen-free, red lilac RAL 4001, shielded (Tinned copper braided shield), Socket straight M12 SPEEDCON, coding: A, on Socket straight M12 SPEEDCON, coding: A and Plug straight M12 SPEEDCON, coding: A, cable length: 15 m, all connectors unshielded, Shield connected to pin 1
- 1436013 - Bus system cable, CANopen®, DeviceNet™, 5-position, PUR halogen-free, red lilac RAL 4001, shielded (Tinned copper braided shield), Socket straight M12 SPEEDCON, coding: A, on Socket straight M12 SPEEDCON, coding: A and Plug straight M12 SPEEDCON, coding: A, cable length: 0.3 m, all connectors unshielded, Shield connected to pin 1
- 1414230 - Bus system cable, CANopen®, DeviceNet™, 5-position, PUR halogen-free, red lilac RAL 4001, shielded (Tinned copper braided shield), Socket straight M12, coding: A, on Socket straight M12, coding: A and Plug straight M12, coding: A, cable length: 0.3 m, all connectors unshielded, Shield connected to pin 1
- 1436026 - Bus system cable, CANopen®, DeviceNet™, 5-position, PUR halogen-free, red lilac RAL 4001, shielded (Tinned copper braided shield), Socket straight M12 SPEEDCON, coding: A, on Socket straight M12 SPEEDCON, coding: A and Plug straight M12 SPEEDCON, coding: A, cable length: 0.5 m, all connectors unshielded, Shield connected to pin 1
- 1436039 - Bus system cable, CANopen®, DeviceNet™, 5-position, PUR halogen-free, red lilac RAL 4001, shielded (Tinned copper braided shield), Socket straight M12 SPEEDCON, coding: A, on Socket straight M12 SPEEDCON, coding: A and Plug straight M12 SPEEDCON, coding: A, cable length: 1 m, all connectors unshielded, Shield connected to pin 1
- 1436042 - Bus system cable, CANopen®, DeviceNet™, 5-position, PUR halogen-free, red lilac RAL 4001, shielded (Tinned copper braided shield), Socket straight M12 SPEEDCON, coding: A, on Socket straight M12 SPEEDCON, coding: A and Plug straight M12 SPEEDCON, coding: A, cable length: 2 m, all connectors unshielded, Shield connected to pin 1
- 1436055 - Bus system cable, CANopen®, DeviceNet™, 5-position, PUR halogen-free, red lilac RAL 4001, shielded (Tinned copper braided shield), Socket straight M12 SPEEDCON, coding: A, on Socket straight M12 SPEEDCON, coding: A and Plug straight M12 SPEEDCON, coding: A, cable length: 5 m, all connectors unshielded, Shield connected to pin 1