Official Distributor
SKU
MPN
1407337
Weight
0.168 kg
Series SAC-5P
SAC-5P-MS/ 2,0-28R/FS SCO RAIL - Sensor/actuator cable
Sensor/actuator cable, 5-position, PE-X halogen-free, black, shielded (Tinned copper braided shield), Plug straight M12 SPEEDCON, coding: A, on Socket straight M12 SPEEDCON, coding: A, cable length: 2 m, For railway applications
- Easy and safe: 100 % electrically tested plug-in components
- Securely locked by special vibration brake
- Resistant to temperature influences – tested for an extended temperature range and for resistance to temperature shocks
- Reliable signal transmission – 360° shielding in environments with electromagnetic interference
Technical Specifications
Notes
General | Further products with variable cable type and variable cable length can be found in the accessories section |
Product properties
Application | Railway applications |
Number of Positions | 5 |
No. of cable outlets | 1 |
Shielded | yes |
Coding | A |
Insulation characteristics
Overvoltage category | II |
Degree of pollution | 3 |
Material specifications
Flammability rating according to UL 94 | V0 |
Seal material | NBR |
Material of grip body | PA 6.6 |
Contact Material | CuSn |
Contact surface material | Ni/Au |
Contact carrier material | PA 6.6 |
Material for screw connection | Zinc die-cast, nickel-plated |
Electrical properties
Insulation resistance | ≥ 100 MΩ |
Nominal voltage UN | 48 V AC |
Nominal voltage UN | 60 V DC |
Nominal current IN | 4 A |
Mechanical data
Insertion/withdrawal cycles | ≥ 100 |
Signaling
Status display | No |
Status display present | No |
Conductor connection
Tightening torque | 0.4 Nm (M12 connector) |
Connection 1
Type | Plug straight M12 SPEEDCON |
Number of Positions | 5 |
Locking Type | SPEEDCON |
Coding type | A |
Connection 2
Type | Socket straight M12 SPEEDCON |
Number of Positions | 5 |
Locking Type | SPEEDCON |
Coding type | A |
Cable/line
Cable Length | 2 m |
Shielded black RADOX® [28R]
Cable weight | 70 kg/km |
Number of Positions | 5 |
Shielded | yes |
Cable Type | Shielded black RADOX® [28R] |
Conductor structure signal line | 19x 0.18 mm |
AWG Signal Line | 20 |
Conductor Cross Section | 5x 0.5 mm² |
Wire diameter incl. insulation | 1.43 mm |
External Cable Diameter | 6.20 mm ±0.3 mm |
Outer sheath, material | PE-X |
External sheath, color | black |
Conductor material | Tin-plated Cu litz wires |
Material wire insulation | PE-X |
Single wire, color | white 1, white 2, white 3, white 4, white 5 |
Overall twist | 5 cores, twisted |
Max. conductor resistance | ≤ 40.1 Ω/km |
Nominal voltage, cable | 600 V AC (Core-ground, U0) |
Nominal voltage, cable | 1000 V AC (Core-ground, U) |
Nominal voltage, cable | ≤ 720 V AC (core-ground) |
Nominal voltage, cable | ≤ 1200 V AC (Core-ground, Um) |
Nominal voltage, cable | ≤ 900 V DC (Core-ground, V0) |
Nominal voltage, cable | ≤ 1500 V DC (Line-line) |
Test voltage | 3500 V AC (50 Hz, 5 min.) |
Test voltage | 8400 V DC (50 Hz, 5 min.) |
Minimum bending radius, fixed installation | 3 x D |
Minimum bending radius, flexible installation | 4 x D |
Smallest bending radius, fixed installation | 19 mm |
Smallest bending radius, movable installation | 25 mm |
Halogen-free | in accordance with EN 50267-2-1 |
Flame resistance | EN 60332-1-2 |
Flame resistance | EN 50266 |
Flame resistance | EN 60332-3-25 |
Flame resistance | NF C32-070, 2.1 |
Flame resistance | NF C32-070, 2.2 |
Flame resistance | UL 1685, 12 (FT4) |
Flame resistance | in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01) |
Fume corrosiveness | EN 50267-2-2 |
Fume toxicity | BS 6853 B.1 |
Fume toxicity | EN 50305, 9.2 |
Concentration of fumes | BS 6853 D.8.7 |
Concentration of fumes | EN 61034-2 |
Concentration of fumes | UL 1685, 12 (FT4) |
Resistance to Oil | according to IRM 902, 72 h at 100 °C |
Fire protection in rail vehicles | BS 6853 (Category Ia, Ib, II) |
Fire protection in rail vehicles | GM/RT 2130 (Category Ia, Ib, II) |
Fire protection in rail vehicles | EN 45545 (Risk level HL1 - HL3) |
Fire protection in rail vehicles | DIN 5510 (Fire protection level 1, 2, 3, 4) |
Fire protection in rail vehicles | NF F16-101 (Category A1, A2, B) |
Fire protection in rail vehicles | NF F16-101 (Class C/F0) |
Fire protection in rail vehicles | NFPA 130 |
Fire protection in rail vehicles | UNI CEI 11170 (Risk level LR1 - LR4) |
Other resistance | Resistance to fuels (according to IRM 903, 168 h at 70 °C) |
Ambient Temperature (Operation) | -50 °C ... 120 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -25 °C ... 90 °C (Cable, flexible installation) |
Ambient conditions
Degree of Protection | IP65 |
Ambient Temperature (Operation) | -40 °C ... 85 °C (Plug / socket) |
M12
Standard designation | M12 connector |
Standards/specifications | IEC 61076-2-101 |
Standard designation | Shock, vibration |
Standards/specifications | EN 50155 |
Accessories
Why Proax for Phoenix Contact SAC-5P-MS/ 2,0-28R/FS SCO RAIL?
Proax is an authorized distributor of Phoenix Contact SAC-5P-MS/ 2,0-28R/FS SCO RAIL and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Alternate Names | SAC5PMS2028RFSSCORAIL |
Pack Size | 1 |
Recommended