0.168 kg
Series SAC-5P
SAC-5P-MS/ 2,0-28R/FS SCO RAIL - Sensor/actuator cable
Sensor/actuator cable, 5-position, PE-X halogen-free, black, shielded (Tinned copper braided shield), Plug straight M12 SPEEDCON, coding: A, on Socket straight M12 SPEEDCON, coding: A, cable length: 2 m, For railway applications
- Easy and safe: 100 % electrically tested plug-in components
- Securely locked by special vibration brake
- Resistant to temperature influences – tested for an extended temperature range and for resistance to temperature shocks
- Reliable signal transmission – 360° shielding in environments with electromagnetic interference
Technical Specifications
Notes
General | Further products with variable cable type and variable cable length can be found in the accessories section |
Product properties
Application | Railway applications |
Number of Positions | 5 |
No. of cable outlets | 1 |
Shielded | yes |
Coding | A |
Insulation characteristics
Overvoltage category | II |
Degree of pollution | 3 |
Material specifications
Flammability rating according to UL 94 | V0 |
Seal material | NBR |
Material of grip body | PA 6.6 |
Contact Material | CuSn |
Contact surface material | Ni/Au |
Contact carrier material | PA 6.6 |
Material for screw connection | Zinc die-cast, nickel-plated |
Electrical properties
Insulation resistance | ≥ 100 MΩ |
Nominal voltage UN | 48 V AC |
Nominal voltage UN | 60 V DC |
Nominal current IN | 4 A |
Mechanical data
Insertion/withdrawal cycles | ≥ 100 |
Signaling
Status display | No |
Status display present | No |
Conductor connection
Tightening torque | 0.4 Nm (M12 connector) |
Connection 1
Type | Plug straight M12 SPEEDCON |
Number of Positions | 5 |
Locking Type | SPEEDCON |
Coding type | A |
Connection 2
Type | Socket straight M12 SPEEDCON |
Number of Positions | 5 |
Locking Type | SPEEDCON |
Coding type | A |
Cable/line
Cable Length | 2 m |
Shielded black RADOX® [28R]
Cable weight | 70 kg/km |
Number of Positions | 5 |
Shielded | yes |
Cable Type | Shielded black RADOX® [28R] |
Conductor structure signal line | 19x 0.18 mm |
AWG Signal Line | 20 |
Conductor Cross Section | 5x 0.5 mm² |
Wire diameter incl. insulation | 1.43 mm |
External Cable Diameter | 6.20 mm ±0.3 mm |
Outer sheath, material | PE-X |
External sheath, color | black |
Conductor material | Tin-plated Cu litz wires |
Material wire insulation | PE-X |
Single wire, color | white 1, white 2, white 3, white 4, white 5 |
Overall twist | 5 cores, twisted |
Max. conductor resistance | ≤ 40.1 Ω/km |
Nominal voltage, cable | 600 V AC (Core-ground, U0) |
Nominal voltage, cable | 1000 V AC (Core-ground, U) |
Nominal voltage, cable | ≤ 720 V AC (core-ground) |
Nominal voltage, cable | ≤ 1200 V AC (Core-ground, Um) |
Nominal voltage, cable | ≤ 900 V DC (Core-ground, V0) |
Nominal voltage, cable | ≤ 1500 V DC (Line-line) |
Test voltage | 3500 V AC (50 Hz, 5 min.) |
Test voltage | 8400 V DC (50 Hz, 5 min.) |
Minimum bending radius, fixed installation | 3 x D |
Minimum bending radius, flexible installation | 4 x D |
Smallest bending radius, fixed installation | 19 mm |
Smallest bending radius, movable installation | 25 mm |
Halogen-free | in accordance with EN 50267-2-1 |
Flame resistance | EN 60332-1-2 |
Flame resistance | EN 50266 |
Flame resistance | EN 60332-3-25 |
Flame resistance | NF C32-070, 2.1 |
Flame resistance | NF C32-070, 2.2 |
Flame resistance | UL 1685, 12 (FT4) |
Flame resistance | in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01) |
Fume corrosiveness | EN 50267-2-2 |
Fume toxicity | BS 6853 B.1 |
Fume toxicity | EN 50305, 9.2 |
Concentration of fumes | BS 6853 D.8.7 |
Concentration of fumes | EN 61034-2 |
Concentration of fumes | UL 1685, 12 (FT4) |
Resistance to Oil | according to IRM 902, 72 h at 100 °C |
Fire protection in rail vehicles | BS 6853 (Category Ia, Ib, II) |
Fire protection in rail vehicles | GM/RT 2130 (Category Ia, Ib, II) |
Fire protection in rail vehicles | EN 45545 (Risk level HL1 - HL3) |
Fire protection in rail vehicles | DIN 5510 (Fire protection level 1, 2, 3, 4) |
Fire protection in rail vehicles | NF F16-101 (Category A1, A2, B) |
Fire protection in rail vehicles | NF F16-101 (Class C/F0) |
Fire protection in rail vehicles | NFPA 130 |
Fire protection in rail vehicles | UNI CEI 11170 (Risk level LR1 - LR4) |
Other resistance | Resistance to fuels (according to IRM 903, 168 h at 70 °C) |
Ambient Temperature (Operation) | -50 °C ... 120 °C (cable, fixed installation) |
Ambient Temperature (Operation) | -25 °C ... 90 °C (Cable, flexible installation) |
Ambient conditions
Degree of Protection | IP65 |
Ambient Temperature (Operation) | -40 °C ... 85 °C (Plug / socket) |
M12
Standard designation | M12 connector |
Standards/specifications | IEC 61076-2-101 |
Standard designation | Shock, vibration |
Standards/specifications | EN 50155 |
Accessories
Why Proax for Phoenix Contact 1407337?
Proax is an authorized distributor of Phoenix Contact 1407337 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.