Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
SAC-5P-MS/ 1,0-28R/FS SCO RAIL
Weight
0.101 kg
Series SAC-5P

SAC-5P-MS/ 1,0-28R/FS SCO RAIL - Sensor/actuator cable

Sensor/actuator cable, 5-position, PE-X halogen-free, black, shielded (Tinned copper braided shield), Plug straight M12 SPEEDCON, coding: A, on Socket straight M12 SPEEDCON, cable length: 1 m, For railway applications

  • Easy and safe: 100 % electrically tested plug-in components
  • Securely locked by special vibration brake
  • Resistant to temperature influences – tested for an extended temperature range and for resistance to temperature shocks
  • Reliable signal transmission – 360° shielding in environments with electromagnetic interference
Technical Specifications

Product properties

ApplicationRailway applications
Number of Positions5
No. of cable outlets1
Shieldedyes
CodingA

Insulation characteristics

Overvoltage categoryII
Degree of pollution3

Material specifications

Flammability rating according to UL 94V0
Seal materialNBR
Material of grip bodyPA 6.6
Contact MaterialCuSn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material for screw connectionZinc die-cast, nickel-plated

Electrical properties

Insulation resistance≥ 100 MΩ
Nominal voltage UN48 V AC
Nominal voltage UN60 V DC
Nominal current IN4 A

Signaling

Status displayNo
Status display presentNo

Connection 1

TypePlug straight M12 SPEEDCON
Number of Positions5
Locking TypeSPEEDCON
Coding typeA

Connection 2

TypeSocket straight M12 SPEEDCON
Number of Positions5
Locking TypeSPEEDCON

Cable/line

Cable Length1 m

Shielded black RADOX® [28R]

Cable weight70 kg/km
Number of Positions5
Shieldedyes
Cable TypeShielded black RADOX® [28R]
Conductor structure signal line19x 0.18 mm
AWG Signal Line20
Conductor Cross Section5x 0.5 mm²
Wire diameter incl. insulation1.43 mm
External Cable Diameter6.20 mm ±0.3 mm
Outer sheath, materialPE-X
External sheath, colorblack
Conductor materialTin-plated Cu litz wires
Material wire insulationPE-X
Single wire, colorwhite 1, white 2, white 3, white 4, white 5
Overall twist5 cores, twisted
Max. conductor resistance≤ 40.1 Ω/km
Nominal voltage, cable600 V AC (Core-ground, U0)
Nominal voltage, cable1000 V AC (Core-ground, U)
Nominal voltage, cable≤ 720 V AC (core-ground)
Nominal voltage, cable≤ 1200 V AC (Core-ground, Um)
Nominal voltage, cable≤ 900 V DC (Core-ground, V0)
Nominal voltage, cable≤ 1500 V DC (Line-line)
Test voltage3500 V AC (50 Hz, 5 min.)
Test voltage8400 V DC (50 Hz, 5 min.)
Minimum bending radius, fixed installation3 x D
Minimum bending radius, flexible installation4 x D
Smallest bending radius, fixed installation19 mm
Smallest bending radius, movable installation25 mm
Halogen-freein accordance with EN 50267-2-1
Flame resistanceEN 60332-1-2
Flame resistanceEN 50266
Flame resistanceEN 60332-3-25
Flame resistanceNF C32-070, 2.1
Flame resistanceNF C32-070, 2.2
Flame resistanceUL 1685, 12 (FT4)
Flame resistancein accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Fume corrosivenessEN 50267-2-2
Fume toxicityBS 6853 B.1
Fume toxicityEN 50305, 9.2
Concentration of fumesBS 6853 D.8.7
Concentration of fumesEN 61034-2
Concentration of fumesUL 1685, 12 (FT4)
Resistance to Oilaccording to IRM 902, 72 h at 100 °C
Fire protection in rail vehiclesBS 6853 (Category Ia, Ib, II)
Fire protection in rail vehiclesGM/RT 2130 (Category Ia, Ib, II)
Fire protection in rail vehiclesEN 45545 (Risk level HL1 - HL3)
Fire protection in rail vehiclesDIN 5510 (Fire protection level 1, 2, 3, 4)
Fire protection in rail vehiclesNF F16-101 (Category A1, A2, B)
Fire protection in rail vehiclesNF F16-101 (Class C/F0)
Fire protection in rail vehiclesNFPA 130
Fire protection in rail vehiclesUNI CEI 11170 (Risk level LR1 - LR4)
Other resistanceResistance to fuels (according to IRM 903, 168 h at 70 °C)
Ambient Temperature (Operation)-50 °C ... 120 °C (cable, fixed installation)
Ambient Temperature (Operation)-25 °C ... 90 °C (Cable, flexible installation)

Ambient conditions

Degree of ProtectionIP65
Ambient Temperature (Operation)-40 °C ... 85 °C (Plug / socket)

M12

Standard designationM12 connector
Standards/specificationsIEC 61076-2-101
Standard designationShock, vibration
Standards/specificationsEN 50155

Why Proax for Phoenix Contact 1419831?

Proax is an authorized distributor of Phoenix Contact 1419831 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability