Featured
Official Distributor
SKU
MPN
UTTB 4
Weight
0.019 kg
Series UTTB
UTTB 4 - Double-level terminal block
Double-level terminal block, nom. voltage: 800 V, nominal current: 30 A, connection method: Screw connection, 1st and 2nd level, Rated cross section: 4 mm2, cross section: 0.14 mm2 - 6 mm2, mounting type: NS 35/7,5, NS 35/15, color: gray
- Since there are two function shafts per level, all potential distribution tasks can be implemented quickly
- For a clear overview, each terminal point supports large-surface labeling
- As an option, the levels can be connected using the FBS‑PV UT vertical bridge
- For example, two separate potentials can by routed side by side with the help of bridging between non-adjacent terminal blocks
- Tested for railway applications
Technical Specifications
Product properties
Product family | UTTB |
Area of application | Railway industry |
Area of application | Machine building |
Area of application | Plant engineering |
Area of application | Process industry |
Number of Connections | 4 |
Number of rows | 2 |
Potentials | 2 |
Insulation characteristics
Overvoltage category | III |
Degree of pollution | 3 |
Electrical properties
Rated surge voltage | 8 kV |
Maximum power dissipation for nominal condition | 1.02 W |
Connection data
Number of connections per level | 2 |
Nominal cross section | 4 mm² |
1st and 2nd level
Screw thread | M3 |
Tightening torque | 0.6 ... 0.8 Nm |
Stripping length | 9 mm |
Internal cylindrical gage | A4 |
Connection in acc. with standard | IEC 60947-7-1 |
Conductor cross section rigid | 0.14 mm² ... 6 mm² |
Cross section AWG | 26 ... 10 (converted acc. to IEC) |
Conductor cross section flexible | 0.14 mm² ... 6 mm² |
Conductor cross section, flexible [AWG] | 26 ... 10 (converted acc. to IEC) |
Conductor cross-section flexible (ferrule without plastic sleeve) | 0.14 mm² ... 4 mm² |
Flexible conductor cross section (ferrule with plastic sleeve) | 0.14 mm² ... 4 mm² |
2 conductors with same cross section, solid | 0.14 mm² ... 1.5 mm² |
2 conductors with same cross section, flexible | 0.14 mm² ... 1.5 mm² |
2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.14 mm² ... 1.5 mm² |
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² ... 2.5 mm² |
Nominal Current | 30 A |
Maximum Load Current | 36 A (with 6 mm² conductor cross section) |
Nominal Voltage | 800 V |
Nominal cross section | 4 mm² |
Rated data (ATEX/IECEx)
Identification | II 2 GD Ex eb IIC Gb |
Operating temperature range | -60 °C ... 110 °C |
Ex-certified accessories | 3047293 D-UTTB 2,5/4 |
Ex-certified accessories | 3047303 DP-UTTB 2,5/4 |
Ex-certified accessories | 3047316 ATP-UTTB 2,5/4 |
Ex-certified accessories | 1212587 SF-SL 0,6X3,5-100 S-VDE |
Ex-certified accessories | 3022276 CLIPFIX 35-5 |
Ex-certified accessories | 3022218 CLIPFIX 35 |
List of bridges | Plug-in bridge / FBS 2-6 / 3030336 |
List of bridges | Plug-in bridge / FBS 3-6 / 3030242 |
List of bridges | Plug-in bridge / FBS 4-6 / 3030255 |
List of bridges | Plug-in bridge / FBS 5-6 / 3030349 |
List of bridges | Plug-in bridge / FBS 10-6 / 3030271 |
List of bridges | Plug-in bridge / FBS 20-6 / 3030365 |
Bridge data | 25.5 A / 4 mm² |
Ex temperature increase | 40 K (28.5 A / 4 mm²) |
Rated voltage | 440 V |
for bridging with bridge | 440 V |
- At bridging between non-adjacent terminal blocks | 275 V |
- At bridging between non-adjacent terminal blocks via PE terminal block | 275 V |
- At cut-to-length bridging with cover | 220 V |
- At cut-to-length bridging with partition plate | 176 V |
Rated Insulation Voltage | 400 V |
Output | (Permanent) |
Ex level General
Rated current | 25.5 A |
Maximum Load Current | 31.5 A |
Ex connection data General
Torque range | 0.6 Nm ... 0.8 Nm |
Nominal cross section | 4 mm² |
Rated cross section AWG | 12 |
Connection capacity rigid | 0.14 mm² ... 6 mm² |
Connection capacity AWG | 26 ... 10 |
Connection capacity flexible | 0.14 mm² ... 4 mm² |
Connection capacity AWG | 26 ... 12 |
2 conductors with same cross section, solid | 0.14 mm² ... 1.5 mm² |
2 conductors with the same cross-section AWG rigid | 26 ... 16 |
2 conductors with same cross section, stranded | 0.14 mm² ... 1.5 mm² |
2 conductors with the same cross-section AWG flexible | 26 ... 16 |
Output | (Permanent) |
Ex level Level 1
Contact resistance | 0.35 mΩ |
Output | (Permanent) |
Ex level Level 2
Contact resistance | 0.2 mΩ |
Dimensions
Width | 6.2 mm |
End cover width | 2.2 mm |
Height | 69.9 mm |
Depth on NS 35/7,5 | 65 mm |
Depth on NS 35/15 | 72.5 mm |
Material specifications
Color | gray |
Flammability rating according to UL 94 | V0 |
Insulating material group | I |
Insulating material | PA |
Static insulating material application in cold | -60 °C |
Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
Surface flammability NFPA 130 (ASTM E 162) | passed |
Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
Surge voltage test
Result | Test passed |
Temperature-rise test
Requirement temperature-rise test | Increase in temperature ≤ 45 K |
Result | Test passed |
Short-time withstand current 4 mm² | 0.48 kA |
Short-time withstand current 6 mm² | 0.72 kA |
Result | Test passed |
Power-frequency withstand voltage
Test voltage setpoint | 2 kV |
Result | Test passed |
Mechanical data
Open side panel | Yes |
Mechanical strength
Result | Test passed |
Attachment on the carrier
DIN rail/fixing support | NS 35 |
Test force setpoint | 1 N |
Result | Test passed |
Test for conductor damage and slackening
Rotation speed | 10 rpm |
Revolutions | 135 |
Conductor cross section/weight | 0.14 mm² / 0.2 kg |
Conductor cross section/weight | 4 mm² / 0.9 kg |
Conductor cross section/weight | 6 mm² / 1.4 kg |
Result | Test passed |
Needle-flame test
Time of exposure | 30 s |
Result | Test passed |
Ambient conditions
Ambient Temperature (Operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
Ambient temperature (assembly) | -5 °C ... 70 °C |
Ambient temperature (actuation) | -5 °C ... 70 °C |
Permissible humidity (operation) | 20 % ... 90 % |
Permissible humidity (storage/transport) | 30 % ... 70 % |
Standards and Regulations
Connection in acc. with standard | IEC 60947-7-1 |
Mounting
Mounting Type | NS 35/7,5 |
Mounting Type | NS 35/15 |
Accessories
Why Proax for Phoenix Contact 3044814?
Proax is an authorized distributor of Phoenix Contact 3044814 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 50 |
Recommended
- Bloc de jonction à couteau de sectionnement, avec vis à alvéole pour la réception des points test, tension nominale: 24 V, intensité nominale: 30 A, type de raccordement: Raccordement vissé, Section de référence: 4 mm2, section : 0,14 mm2 - 6 mm2, type de raccordement: Raccordement vissé, Section de référence: 4 mm2, section : 0,14 mm2 - 6 mm2, montage: NS 35/7,5, NS 35/15, coloris: gris
- 3044801 - Disconnect terminal block, Current and voltage are determined by the plug used., With test socket screws for insertion of test plugs, nom. voltage: 500 V, nominal current: 30 A, connection method: Screw connection, Rated cross section: 4 mm2, cross section: 0.14 mm2 - 6 mm2, Disconnect zone, mounting: NS 35/7,5, NS 35/15, color: gray