Official Distributor
SKU
MPN
ELR W3/ 9-400
Weight
0.777 kg
This product is Not Cancellable/Not Returnable
Series ELR-W
ELR W3/ 9-400 - Reversing load relay
Electronic reversing load relay, for direct driving of equipment in the 3-phase network, with light indicator and protection circuit, output: 110-440 V AC/3 x 9 A
- High switching frequency
- Noise and wear-free switching up to 500 V AC/9 A
- Protective circuit in input and output
- LEDs for forward and reverse running, operating voltage, and impermissible control
Technical Specifications
Product properties
Operating mode | 100% operating factor |
Insulation characteristics
Insulation | Basic insulation |
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation | Basic insulation |
Electrical properties
Number of phases | 3 |
Maximum power dissipation for nominal condition | 13.5 W |
Mains type | 3-phase |
Test voltage (Input/output) | 2.5 kV (50 Hz, 60 s) |
Reversing frequency | ≤ 10 Hz (at cos φ = 0.5) |
Control
Input name | Control input right/left |
Quiescent current | 40 mA |
Rated actuating voltage UC | 24 V DC |
Triggering voltage range | 19.2 V DC ... 30 V DC |
Voltage range with reference to UC | 0.8 ... 1.25 |
Voltage range with reference to UC | 0.8 ... 1.25 |
Rated actuating current IC | 7.5 mA |
Reaction time in normal load operation | 50 ms |
Reaction time in normal load operation | 50 ms |
Protective circuit | Reverse polarity protection; Polarity protection diode |
Protective circuit | Surge protection |
Operating voltage display | Green LED |
Error indication | Red LED |
Status display | Yellow LED |
Switch-over frequency | < 10 Hz (at cos φ > 0.5) |
Switchover time RL/LL (turn-on time) | 20 ms |
AC output
Rated operating voltage Ue | 400 V AC |
Operating voltage range | 110 V AC ... 440 V AC |
Peak offstate voltage | 1000 V |
Mains frequency | 50 Hz |
Mains frequency | 60 Hz |
Load Current | 9 A (see derating curve) |
Load current range | 150 mA |
Leakage current | typ. 7 mA |
Residual voltage | typ. 1.5 V |
Surge current | 230 A (tp = 10 ms, at 25 °C) |
Max. load value | 265 A2s |
Protective circuit | RC element; RC element |
Protective circuit | Surge protection |
Surge voltage protection | > 750 V |
Control circuits
Connection Method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 6 mm² |
Conductor cross section flexible | 0.2 mm² ... 4 mm² |
Conductor cross section AWG | 24 ... 10 |
Load circuit
Connection Method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 6 mm² |
Conductor cross section flexible | 0.2 mm² ... 4 mm² |
Conductor cross section AWG | 24 ... 10 |
Dimensions
Width | 62 mm |
Height | 84 mm |
Depth | 110 mm |
Material specifications
Color | green (RAL 6021) |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -20 °C ... 60 °C |
Ambient temperature (storage/transport) | -20 °C ... 70 °C |
Air clearances and creepage distances between the power circuits
Standards/regulations | EN 50178 |
EMC regulations
Standards/regulations | EN 61000-6-2 |
Standards/regulations | EN 61000-6-4 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | Can be aligned with > 20 mm spacing |
Mounting Position | Vertical (horizontal DIN rail) |
Why Proax for Phoenix Contact 2964173?
Proax is an authorized distributor of Phoenix Contact 2964173 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended