ELR W3-230AC/500AC- 9 - Solid-state reversing contactor
Three-phase solid-state reversing contactor with 230 V AC input, 9 A output current, zero voltage switch, optionally with thermal fuse
- Optional thermal fuse
- Stable and short switching times
- Noise and wear-free switching
- Long service life
- Integrated protection circuit
- High switching frequency
- Integrated locking and load wiring
Technical Specifications
Product properties
Operating mode | 100% operating factor |
Electrical properties
Number of phases | 3 |
Test voltage (Input/output) | 5 kVrms (50 Hz, 60 s) |
Switching frequency | max. 1 Hz |
Reversing frequency | ≤ 2 Hz |
Insulation characteristics
Rated Insulation Voltage | 500 V |
Rated surge voltage | 6 kV |
Overvoltage category | III |
Degree of pollution | 2 |
Insulation characteristics between the control input voltage to the main circuit | Basic insulation |
Control
Input name | Control input right/left |
Mains frequency | 50 Hz |
Mains frequency | 60 Hz |
Rated actuating voltage UC | 230 V AC |
Triggering voltage range | 92 V AC ... 253 V AC |
Voltage range with reference to UC | 0.4 ... 1.1 |
Voltage range with reference to UC | 0.4 ... 1.1 |
Rated actuating current IC | 11.2 mA |
Switching threshold | 48 V AC (“0” signal) |
Switching threshold | 96 V AC (“1” signal) |
Protective circuit | Surge protection; Varistor |
Error indication | Red LED |
Status display | Yellow LED |
AC output
Rated operating voltage Ue | 500 V AC |
Operating voltage range | 48 V AC ... 575 V AC |
Rated operating current at AC-51 | 9 A |
Rated operating current at AC-53a | 9 A |
Peak offstate voltage | 1200 V |
Mains frequency | 40 Hz ... 100 Hz |
Load current range | 100 mA ... 9 A (see to derating) |
Leakage current | 6 mA |
Residual voltage | < 1.5 V |
Surge current | 300 A (t = 10 ms) |
Max. load value | 580 A2s |
Protective circuit | RCV circuit |
Surge voltage protection | > 575 V AC |
Control circuits
Connection Method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Tightening torque | 0.5 Nm ... 0.6 Nm |
Tightening torque | 5 lbf-in. ... 7 lbf-in. |
Load circuit
Connection Method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Tightening torque | 0.5 Nm ... 0.6 Nm |
Tightening torque | 5 lbf-in. ... 7 lbf-in. |
Signaling
Status display | Yellow LED |
Error indication | Red LED |
Dimensions
Width | 67.5 mm |
Height | 99 mm |
Depth | 114.5 mm |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 70 °C |
Ambient temperature (storage/transport) | -25 °C ... 70 °C |
UL approval
Certificate | NMFT.E323771 |
UL data
SCCR | 5 kA (20 A RK5 (standard fault) fuse) |
Standards/regulations
Standards/regulations | DIN EN 50178 |
Standards/regulations | EN 60947 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | Can be aligned with spacing = 20 mm |
Mounting Position | Vertical (horizontal DIN rail) |
Accessories
Why Proax for Phoenix Contact 2297329?
Proax is an authorized distributor of Phoenix Contact 2297329 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended