MPN
ELR W3-230AC/500AC- 2I
Weight
0.313 kg
This product is Not Cancellable/Not Returnable
Series ELR-W

ELR W3-230AC/500AC- 2I - Hybrid motor starter

"4 in 1" three-phase semiconductor reversing contactor with 230 V AC input, 2 A output current, emergency stop function, and adjustable overload shutdown.

  • 22.5 mm wide
  • Safety level in accordance with IEC 61508-1: SIL 3, ISO 13849: PL e
  • Reduction in wiring
  • Long service life
  • Space saving
  • 3-phase loop bridges
  • Adjustable current for bimetal function
  • Low-wear switching
Technical Specifications

Product properties

Product familyCONTACTRON
Operating mode100% operating factor

Electrical properties

Number of phases3
Motor starter typeReversing starter
Maximum power dissipation for nominal condition2.2 W
Switching frequency≤ 2 Hz (Load-dependent)
Maximum power dissipation4.7 W
Minimum power dissipation2.6 W

Supply

Rated control circuit supply voltage US230 V AC
Control supply voltage range92 V AC ... 253 V AC
Rated control supply current IS4 mA
Mains frequency40/100 Hz
Protective circuitSurge protection

Insulation characteristics

Rated Insulation Voltage500 V
Rated surge voltage6 kV
Overvoltage categoryIII
Degree of pollution2
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuitSafe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuitBasic insulation (IEC 60947-1) at operating voltage 300 V AC ... 500 V AC
Isolation characteristics between the control input and control supply voltage to auxiliary circuitSafe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC

Control

Input nameControl input right/left
Rated actuating voltage UC230 V AC
Triggering voltage range92 V AC ... 253 V AC
Rated actuating current IC7 mA
Switching threshold44 V AC (“0” signal)
Switching threshold85 V AC (“1” signal)
Switching level< 5 V DC (For EMERGENCY STOP)
Typical response time< 35 ms
Typical turn-off time< 80 ms

AC output

Rated operating voltage Ue500 V AC
Operating voltage range42 V AC ... 550 V AC
Rated operating current Ie2.4 A (AC-51)
Rated operating current Ie2.4 A (AC-53a)
Mains frequency50/60 Hz
Load current range180 mA ... 2.4 A (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2Class 10A
Cooling time20 min. (for auto reset)
Leakage current0 mA
Residual voltage< 0.3 V
Surge current100 A (t = 10 ms)
Protective circuitSurge protection

Acknowledge output

NoteConfirmation: floating change-over contact, signal contact
Contact switching type1 changeover contact
Switching capacity in accordance with IEC 60947-5-13 A (230 V, AC15)
Switching capacity in accordance with IEC 60947-5-12 A (24 V, DC13)
Residual voltage< 0.5 V

Control circuits

Connection MethodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Tightening torque0.5 Nm ... 0.6 Nm
Tightening torque5 lbf-in. ... 7 lbf-in.

Load circuit

Connection MethodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Tightening torque0.5 Nm ... 0.6 Nm
Tightening torque5 lbf-in. ... 7 lbf-in.

Signaling

Status displayYellow LED
Operating voltage displayGreen LED
Error indicationRed LED

Dimensions

Width22.5 mm
Height107 mm
Depth114 mm

Material specifications

Flammability rating according to UL 94V0 (Housing)

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m

UKCA

CertificateUKCA-compliant

ATEX

Identification II (2) G [Ex e] [Ex d] [Ex px]
Identification II (2) D [Ex t] [Ex p]
CertificatePTB 07 ATEX 3145

UL approval

CertificateNLDX.E228652

Safety Integrity Level (SIL, IEC 61508)

Identification≤ 3
NoteSafe shutdown
Identification2
NoteMotor protection

Performance Level (ISO 13849)

Identification≤ e
NoteSafe shutdown

Category (ISO 13849)

Identification≤ 3
NoteSafe shutdown

UL data

SCCR100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
SCCR5 kA (500 V AC (fuse: 20 A RK5 (standard fault)))
FLA2.4 A (500 V AC)
Group installation20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
Group installation30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded)
Category codeNLDX

Standards/regulations

Standards/regulationsEN 60947
Standards/regulationsIEC 61508
Standards/regulationsISO 13849

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsCan be aligned with spacing = 20 mm
Mounting PositionVertical (horizontal DIN rail)

Why Proax for Phoenix Contact 2297044?

Proax is an authorized distributor of Phoenix Contact 2297044 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Available for order

Phoenix Contact Availability