Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2903327
Weight
0.069 kg
This product is Not Cancellable/Not Returnable
Series RIF

RIF-1-RPT-LV-230AC/2X21AU - Relay Module

Preassembled relay module with Push-in connection, consisting of: relay base, multi-layer contact relay, plug-in display/interference suppression module, and retaining bracket. Contact switching type: 2 changeover contacts. Input voltage: 230 V AC

Technical Specifications

Notes

Notes on operationFBS 2-6... plug-in bridge for the input side (A2) and FBS-2-8... plug-in bridge for the output side (11/21)

Product properties

Product familyRIFLINE complete
ApplicationUniversal
Operating mode100% operating factor
Mechanical service lifeapprox. 107 cycles

Insulation characteristics

InsulationSafe isolation between input and output
InsulationBasic insulation between the changeover contacts
InsulationSafe isolation between input and output
InsulationBasic insulation between the changeover contacts
Overvoltage categoryIII
Pollution degree2

Electrical properties

Service life electricalsee diagram
Maximum power dissipation for nominal condition1.4 W
Test voltage (Winding/contact)2.5 kVrms (50 Hz, 1 min., winding/contact)
Test voltage (Changeover contact/changeover contact)2.5 kVrms (50 Hz, 1 min., changeover contact/changeover contact)
Rated surge voltage6 kV (Input/output)
Rated surge voltage4 kV (between the changeover contacts)

Coil side

Nominal input voltage UN230 V AC
Input voltage range184 V AC ... 264.5 V AC (20 °C)
Input voltage range in reference to UNsee diagram
Mains frequency50/60 Hz
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN6 mA
Typical response time3 ms ... 12 ms
Typical release time range3 ms ... 20 ms
Coil Voltage230 V AC
Protective circuitVaristor
Operating voltage displayYellow LED

Switching

Contact switching type2 changeover contacts
Type of switch contactSingle contact
Contact MaterialAgNi, hard gold-plated
Maximum Switching Voltage30 V AC
Maximum Switching Voltage36 V DC
Minimum Switching Voltage100 mV (10 mA)
Limiting Continuous Current50 mA
Maximum Inrush Current50 mA
Min. switching current1 mA (24 V)
Interrupting rating (ohmic load) max.1.2 W (at 24 V DC)
Utilization category CB Scheme (IEC 60947-5-1)AC15, 1.5 A/240 V (N/O contact)
Utilization category CB Scheme (IEC 60947-5-1)AC15, 2 A/250 V (N/C contact)
Utilization category CB Scheme (IEC 60947-5-1)DC13, 2 A/24 V (N/C contact)
Utilization category CB Scheme (IEC 60947-5-1)DC13, 0.2 A/250 V (N/O contact)

Switching: when the gold layer is destroyed

Notethe following values are applicable if a gold layer is destroyed
Contact MaterialAgNi
Maximum Switching Voltage250 V AC/DC
Minimum Switching Voltage5 V (at 10 mA)
Maximum Inrush Current12 A (20 ms, N/O contacts)
Min. switching current10 mA (At 5 V)
Interrupting rating (ohmic load) max.192 W (at 24 V DC)
Interrupting rating (ohmic load) max.96 W (at 48 V DC)
Interrupting rating (ohmic load) max.60 W (at 60 V DC)
Interrupting rating (ohmic load) max.44 W (at 110 V DC)
Interrupting rating (ohmic load) max.57 W (at 220 V DC)
Interrupting rating (ohmic load) max.2000 VA (for 250 V AC)
Switching capacity2 A (at 24 V, DC13)
Switching capacity0.2 A (at 110 V, DC13)
Switching capacity0.2 A (at 250 V, DC13)
Switching capacity2 A (at 24 V, AC15)
Switching capacity2 A (at 120 V, AC15)
Switching capacity2 A (at 250 V, AC15)

Connection data

Connection MethodPush-in connection
Stripping length8 mm
Conductor cross section rigid0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
Conductor cross section flexible0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block)
Conductor cross section AWG26 ... 16 (solid)
Conductor cross section AWG26 ... 16 (flexible)

Drill hole

Diameter3.2 mm
Width16 mm
Height96 mm
Depth75 mm

Material specifications

Colorgray (RAL 7042)
Flammability rating according to UL 94V2 (Housing)

Ambient conditions

Degree of protection (Relay base)IP20 (Relay base)
Degree of protection (Relay)RT III (Relay)
Ambient Temperature (Operation)-40 °C ... 50 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Corrosive gas test

IdentificationISA-S71.04. G3 Harsh Group
IdentificationEN 60068-2-60

Standards and Regulations

Standards/regulationsIEC 60947-5-1

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsin rows with zero spacing
Mounting Positionany
Accessories

Why Proax for Phoenix Contact RIF-1-RPT-LV-230AC/2X21AU?

Proax is an authorized distributor of Phoenix Contact RIF-1-RPT-LV-230AC/2X21AU and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesRIF1RPTLV230AC2X21AU
Pack Size10
Recommended
Sold in quantities of 10

Available for order