Official Distributor
SKU
MPN
RAD-2400-IFS
Weight
0.206 kg
Series RAD
RAD-2400-IFS - Wireless module
Radioline - 2.4 GHz wireless transceiver with RS-232/RS-485 interface, can be extended with I/O modules, RSMA (female) antenna connection, point-to-point, star, and mesh networks up to 250 stations, range of up to 5 km (with a clear line of sight), for worldwide use
- License-free 2.4 GHz frequency band
- Range of several kilometers thanks to adjustable data rates for the wireless interface
- Quick and easy startup without programming
- High degree of reliability due to Trusted Wireless 2.0 technology (AES encryption, frequency hopping method, and coexistence management)
- Mesh networks of up to 250 devices
- Integrated RS-232/RS-485 interface
- Modular extension with up to 32 I/O extension modules supported
- Extended temperature range of -40 °C … +70 °C
- Approved for use in zone 2
- International approvals
Technical Specifications
Product properties
Application | I/O |
Application | RS-232 |
Application | RS-485 |
Operating mode | I/O data (Default setting, configuration via thumbwheel) |
Operating mode | Serial data (Activation and configuration via PSI-CONF software) |
Operating mode | PLC/Modbus RTU mode (Activation and configuration via PSI-CONF software) |
Operating mode | PLC / Modbus RTU dual mode (Activation and configuration via PSI-CONF software) |
MTTF | 733 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
MTTF | 340 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) |
MTTF | 135 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) |
Insulation characteristics
Overvoltage category | II |
Degree of pollution | 2 |
Electrical properties
Rated Insulation Voltage | 60 V (In accordance with EN/IEC 60079-7) |
Maximum power dissipation for nominal condition | 1.56 W |
Transient surge protection | Yes |
System limits
Designation | Wireless module |
Number of supported devices | ≤ 250 (Addressing via PSI-CONF software) |
Number of supported devices | ≤ 99 (Addressing via thumbwheel) |
Number of possible extension modules | ≤ 32 (per wireless module) |
Designation | Wireless network |
Number of supported devices | ≤ 99 (I/O extension modules per wireless network, serial interfaces deactivated) |
Number of supported devices | 0 (no I/O extension modules can be used) |
Number of supported devices | ≤ 99 (I/O extension modules per wireless network, access to extension modules via Modbus RTU protocol) |
Supply
Supply Voltage | 24 V DC |
Supply Voltage Range | 19.2 V DC ... 30.5 V DC |
Max. current consumption | ≤ 65 mA (at 24 V DC, at 25 °C, stand-alone) |
Max. current consumption | ≤ 6 A (at 24 V DC, with DIN rail connector at full capacity) |
Digital
Output name | RF link relay output |
Number of Outputs | 1 |
Contact switching type | Changeover contact |
Contact Material | PdRu, gold-plated |
Maximum Switching Voltage | 30 V AC/DC |
Maximum Switching Voltage | 60 V DC |
Max. switching current | 500 mA (30 V AC/DC) |
Max. switching current | 300 mA (60 V DC) |
Electrical service life | 5x 105 switching cycles with 0.5 A at 30 V DC |
Analog
Output name | RSSI voltage output |
Number of Outputs | 1 |
Voltage output signal | 0 V ... 3 V |
Connection data
Connection Method | Screw connection |
Stripping length | 7 mm |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Wireless
Range | ± 5 km (The range may be considerably above or below that stated, and depends on the environment, antenna technology, and the product used) |
Serial: RS-232
Data rate | 300 bps / 600 bps / 1.2 kbps / 2.4 kbps / 4.8 kbps / 9.6 kbps / 19.2 kbps / 38.4 kbps / 57.6 kbps / 93.75 kbps / 115.2 kbps |
Connection Method | COMBICON plug-in screw terminal block |
Connection technology | 3-conductor |
Transmission length | ≤ 15 m |
Serial: RS-485
Data rate | 300 bps / 600 bps / 1.2 kbps / 2.4 kbps / 4.8 kbps / 9.6 kbps / 19.2 kbps / 38.4 kbps / 57.6 kbps / 93.75 kbps / 115.2 kbps / 187.5 kbps |
Connection Method | COMBICON plug-in screw terminal block |
Connection technology | 2-conductor |
Transmission length | ≤ 1200 m |
Termination resistor | 390 Ω (switchable via DIP switches) |
Termination resistor | 150 Ω (switchable via DIP switches) |
Termination resistor | 390 Ω (switchable via DIP switches) |
Serial: Configuration interface
Connection Method | S-PORT (socket) |
Wireless
Interface description | Trusted Wireless |
Direction | Bi-directional |
Frequency | 2400 MHz |
Frequency Range | 2.4002 GHz ... 2.4785 GHz |
Channel distance | 1.3 MHz |
Number of channel groups | 8 |
Number of channels per group | 55 |
Transmit capacity, minimum | 0 dBm |
Transmit capacity, maximum | ≤ 20 dBm (100 mW, outside of Europe, adjustable via software) |
Transmit capacity, maximum | ≤ 19 dBm (Europe, can be set via software, depends on the data rate) |
Transmit capacity, maximum | 18 dBm (Default setting, adjustable) |
Data rate | 16 kbps (adjustable) |
Data rate | 125 kbps (Default setting, adjustable) |
Data rate | 250 kbps (adjustable) |
Minimum receiver sensitivity | -106 dBm (16 kbps) |
Minimum receiver sensitivity | -96 dBm (125 kbps) |
Minimum receiver sensitivity | -93 dBm (250 kbps) |
Antenna Connection Method | RSMA (female) |
Security | 128-bit data encryption |
Functions
Wireless licenses | Europe, USA, Canada, additional countries in the e-shop |
Wireless
Frequency band | 2.4 GHz |
Wireless Standard | Trusted Wireless |
Signaling
Status display | Green LED (supply voltage, PWR) |
Status display | Green LED (bus communication, DAT) |
Status display | Red LED (periphery error, ERR) |
Status display | 3x green, 1x yellow LED (LED bar graph receive quality, RSSI) |
Status display | Green LED (receive data, RX) |
Status display | Green LED (transmit data, TX) |
Dimensions
Width | 17.5 mm |
Height | 116 mm |
Depth | 114.5 mm |
Material specifications
Color (Housing) | gray (RAL 7042) |
Material (Housing) | PA 6.6-FR |
Flammability rating according to UL 94 | V0 |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -40 °C ... 70 °C (>55°C derating, see technical documentation) |
Ambient Temperature (Operation) | -40 °F ... 158 °F (>131°F derating, see technical documentation) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Ambient temperature (storage/transport) | -40 °F ... 185 °F |
Altitude | 2000 m |
Permissible humidity (operation) | 20 % ... 85 % |
Permissible humidity (storage/transport) | 20 % ... 85 % |
Shock | 16g, 11 ms |
Vibration (Operation) | in accordance with IEC 60068-2-6: 5g, 10 Hz ... 150 Hz |
CE
Certificate | CE-compliant |
UKCA
Certificate | UKCA-compliant |
ATEX
Identification | II 3 G Ex ec nC IIC T4 Gc |
Certificate | IBExU 15 ATEX B008 X |
Note | Please follow the special installation instructions in the documentation! |
IECEx
Identification | Ex ec nC IIC T4 Gc |
Certificate | IECEx IBE 13.0019X |
EAC Ex
Identification | 2Ex nA nC IIC T4 Gc X |
Certificate | RU C-DE.HB49.B.00033/20 |
UL, USA/Canada
Identification | 508 Listed |
Identification | Class I, Div. 2, Groups A, B, C, D T4A |
Identification | Class I, Zone 2, IIC T4 |
CCC / China-Ex
Identification | Ex ec nC IIC T4 Gc |
Certificate | 2022122310115624 |
Wireless approval, Europe
Note | RED 2014/53/EU |
Wireless approval USA, FCC
Certificate | YG3RAD2400A |
Note | FCC directive, part 15.247 |
Wireless approval for Argentina, RAMATEL
Certificate | C-27397 |
Wireless approval Australia, RCM
Certificate | - |
Wireless approval Brazil, ANATEL
Certificate | 06279-19-06497 |
Wireless approval India, WPC
Certificate | NER-ETA/314 |
Wireless approval Canada, IC
Certificate | 4720B-RAD2400A |
Note | ISC directive RSS 210 |
Wireless approval Morocco, ANRT
Certificate | MR 10464 ANRT 2015 |
Wireless approval Mexico, IFT
Certificate | IFT RCPPHRA17-1112 |
KC approval for South Korea
Certificate | MSIP-CRI-PCK-2901541 |
KC-s
Certificate | KTL 20-KA4BO-0146X |
Wireless approval Taiwan, NCC
Certificate | CCAJ18LP1990T7 |
Wireless approval United Arab Emirates, TRA
Certificate | ER0126713 |
Corrosive gas test
Identification | ISA-S71.04-1985 G3 Harsh Group A |
EMC data
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV (Test Level 3) |
Discharge in air | ± 8 kV (Test Level 3) |
Indirect discharge | ± 6 kV |
Comments | Criterion B |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 26 MHz ... 3 GHz (Test Level 3) |
Field intensity | 10 V/m |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | ± 2 kV (Test Level 3) |
Signal | ± 2 kV |
Comments | Criterion B |
Surge current load (surge)
Standards/regulations | EN 61000-4-5 |
Input | ± 0.5 kV (symmetrical) |
Input | ± 1 kV (asymmetrical) |
Signal | ± 1 kV (asymmetrical) |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Frequency Range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V |
Emitted interference
Emitted radio interference in acc. with EN 55011 | EN 55016-2-3 Class A industrial applications |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Standards and Regulations
Standard designation | Ex Directive (ATEX) |
Standards/specifications | EN 60079-0 |
Standard designation | Ex Directive (ATEX) |
Standards/specifications | EN 60079-15 |
Standards/specifications | EN 300328 |
Standards/specifications | EN 61000-6-4 |
Standards/specifications | EN 61000-6-2 |
Standards/specifications | EN 50371 |
Standards/specifications | EN 60950-1 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | on standard DIN rail NS 35 in accordance with EN 60715 |
Accessories
- 2316275 - Radioline - I/O extension module, 4 NAMUR digital input module used in Radioline and PROFIBUS PA MUX I/O systems. Fulfills the NAMUR proximity sensor standard EN 60947-5-6, and communication to the head stations for Radioline systems and the FB-MUX/HS...PA via the T-BUS connector installed on the DIN rail. This module has channel-to-channel isolation.
- 2906796 - Surge protection, consisting of protective plug and base element, with integrated status indicator and knife disconnection for three signal wires with common reference potential. For HF applications and telecommunications interfaces without supply voltage. Indirect grounding via gas discharge tube, EX e approval for zone 2. Can be used in safety-related circuits up to SIL 3.
Why Proax for Phoenix Contact 2901541?
Proax is an authorized distributor of Phoenix Contact 2901541 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended