Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
BAR-ANT-N-N-EX
Weight
0.173 kg

BAR-ANT-N-N-EX - Antenna barrier

Antenna barrier for control cabinet feed-through, type of protection: Ex i, degree of protection: IP65, barrier installation: zone 2 / 22, antenna installation: in dust and gas Ex area, frequency range: 0.3 GHz ... 6 GHz, connection: 2 x N (female), ATEX, IECEx approval

  • Compact housing design
  • International approvals
  • Use of standard antennas in the hazardous area of zone 0, 1, and 2
  • Universal use (frequency range of 0.3 ... 6 GHz)
  • Supply of all necessary certified components – including as a system solution
  • Inexpensive solution, as there is no need for expensive special antennas
Technical Specifications

Utilization restriction

CCCex noteUse in potentially explosive areas is not permitted in China.

Electrical properties

Frequency Range300 MHz ... 6000 MHz
Test voltage2.1 kV AC (50 Hz / 2 s)
Impedance50 Ω
Insulation voltage input/output265 V AC/DC
Insulation voltage input/output375 V (Peak value)
Maximum error voltage Um253 V AC/DC

Connection data

Connection MethodN (female)
Connection MethodN (female)

Safety data

Input power Pi≤ 2 W (HF input power, 33 dBm, IIC)
Input power Pi≤ 3.5 W (HF input power, 35.4 dBm, IIB)
Input power Pi≤ 6 W (HF input power, 37.7 dBm, I, IIA, III)
Max. internal inductance Linegligible
Max. internal capacitance Ci5.64 pF
Max. output power PoPout ≤ max. HF output power of the wireless module

Dimensions

Height67 mm
Diameter25.00 mm

Material specifications

Material (Housing)Brass, nickel-plated
Material ()CuZn
Material ()PTFE
Material (Seal)Silicon
Material ()CuSn
Material ()Au

Cable/line

400 MHz< 3.5 dB (400 MHz)
868 MHz< 1.2 dB (868 MHz)
900 MHz< 0.9 dB (900 MHz)
2.4 GHz< 0.2 dB (2.4 GHz)
5.8 GHz< 1.8 dB (5.8 GHz)

Ambient conditions

Degree of ProtectionIP65 (when installed)
Ambient Temperature (Operation)-40 °C ... 75 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Air pressure (operation)80 kPa ... 110 kPa

CE

CertificateCE-compliant

ATEX

Identification II (1) G [Ex ia Ga] IIC
Identification II (1) D [Ex ia Da] IIIC
Identification I (M1) [Ex ia Ma] I
Identification II 3 (1) G Ex ec [ia Ga] IIC T6 Gc
Identification II 3 (1) D Ex tc [ia Da] IIIC T80 °C Dc
CertificateIBExU 15 ATEX 1064 X
NotePlease follow the special installation instructions in the documentation!

IECEx

Identification[Ex ia Ga] IIC
Identification[Ex ia Da] IIIC
Identification[Ex ia Ma] I
IdentificationEx ec [ia Ga] IIC T6 Gc
IdentificationEx tc [ia Da] IIIC T80 °C Dc
CertificateIECEx IBE 15.0006X

Mounting

Assembly instructionsOutdoors and indoors
Assembly instructionsConnection-specific attachment plug
Assembly instructionsIn the installed state, the device is suitable for atmospheres containing gas or dust. Ensure that the HF input socket is in the IP54 housing (zone 2, in accordance with EN/IEC 60079-15) or in the IP6x housing (zone 22, in accordance with EN/IEC 60079-31).
Accessories

Why Proax for Phoenix Contact 2702198?

Proax is an authorized distributor of Phoenix Contact 2702198 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Best Sellersin Antennas and cables

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability