Official Distributor
SKU
MPN
ELR H5-I-PT- 24DC/500AC-3-P
Weight
0.303 kg
Series ELR-H
ELR H5-I-PT- 24DC/500AC-3-P - Hybrid motor starter
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 3 A and offers motor protection. Possible supply and relay extension via DIN rail connector.
Technical Specifications
Product properties
Product family | CONTACTRON |
Operating mode | 100% operating factor |
Electrical properties
Number of phases | 3 |
Motor starter type | Reversing starter |
Switching frequency | ≤ 2 Hz (Load-dependent) |
Maximum power dissipation | 4.1 W |
Minimum power dissipation | 0.88 W |
Coordination type | 1 |
Supply
Rated control circuit supply voltage US | 24 V DC |
Control supply voltage range | 19.2 V DC ... 30 V DC |
Rated control supply current IS | 60 mA |
Protective circuit | Surge protection |
Protective circuit | Reverse polarity protection |
Insulation characteristics
Rated Insulation Voltage | 550 V |
Rated surge voltage | 6 kV |
Overvoltage category | III |
Degree of pollution | 2 |
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit | Safe isolation (IEC 60947-1) |
Isolation characteristics between the control input and control supply voltage to auxiliary circuit | Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC |
Emergency tripping
Operate threshold | > 33 A |
Response time | < 0.5 s |
Control
Input name | Control input right/left |
Rated actuating voltage UC | 24 V DC |
Triggering voltage range | 19.2 V DC ... 30 V DC |
Rated actuating current IC | 7 mA |
Switching threshold | 9.6 V (“0” signal) |
Switching threshold | 19.2 V (“1” signal) |
Typical turn-off time | < 30 ms |
Protective circuit | Reverse polarity protection |
AC output
Rated operating voltage Ue | 500 V AC |
Operating voltage range | 42 V AC ... 550 V AC |
Rated operating current Ie | 3 A (AC-51) |
Rated operating current Ie | 3 A (AC-53a) |
Mains frequency | 50/60 Hz |
Load current range | 180 mA ... 3 A |
Trigger characteristic in acc. with IEC 60947-4-2 | Class 10 |
Cooling time | 20 min. (for auto reset) |
Leakage current | 0 mA |
Protective circuit | Surge protection; Varistor |
Acknowledge output
Note | Confirmation: floating change-over contact, signal contact |
Contact switching type | 1 changeover contact |
Switching capacity in accordance with IEC 60947-5-1 | 2 A (24 V, DC13) |
Control circuits
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Load circuit
Connection Method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Signaling
Status display | Yellow LED |
Operating voltage display | Green LED |
Error indication | Red LED |
Dimensions
Width | 22.5 mm |
Height | 107.5 mm |
Depth | 114 mm |
Material specifications
Flammability rating according to UL 94 | V0 (Housing) |
Ambient conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 70 °C (observe derating) |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 2000 m |
UL approval
Certificate | NLDX.E228652 |
Certificate | NRNT.E172140 |
UL data
SCCR | 100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault))) |
SCCR | 5 kA (480 V AC (fuse: 20 A RK5 (standard fault))) |
FLA | 3 A (480 V AC) |
Group installation | 20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded) |
Group installation | 30 A (class CC or J, SCCR 100kA (480 V AC), #24 - 14 AWG max, solid and stranded) |
Category code | NLDX / NRNT |
Horsepower ratings | 0.5 hp (208 V AC) |
Horsepower ratings | 0.5 hp (230 V AC) |
Horsepower ratings | 0.5 hp (240 V AC) |
Horsepower ratings | 1.5 hp (480 V AC) |
Ambient Temperature (Operation) | -25 °C ... 55 °C |
Standards/regulations
Standards/regulations | EN 60947-1 |
Standards/regulations | EN 60947-4-2 |
Mounting
Mounting Type | DIN rail mounting |
Assembly instructions | alignable, for spacing see derating |
Mounting Position | vertical (horizontal DIN rail, motor output below) |
Accessories
Why Proax for Phoenix Contact 2909562?
Proax is an authorized distributor of Phoenix Contact 2909562 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |