2905146
SKU
PHX2905146
MPN
ELR H5-I-PT/500AC-3-IFS
Weight
0.298 kg
This product is Not Cancellable/Not Returnable
Series ELR-H
ELR H5-I-PT/500AC-3-IFS - Hybrid motor starter
Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC, output current: 3 A, adjustable overload shutdown, and Push-in connection, DIN rail connector provided.
- 22.5 mm wide
- Reduction in wiring
- Space saving
- Long service life
- 3-phase loop bridges
- Adjustable current for bimetal function
- Low-wear switching
Technical Specifications
Product properties
| Product family | CONTACTRON |
| Operating mode | 100% operating factor |
Electrical properties
| Number of phases | 3 |
| Motor starter type | Reversing starter |
| Maximum power dissipation for nominal condition | 2.5 W |
| Switching frequency | ≤ 2 Hz (Load-dependent) |
| Maximum power dissipation | 4.1 W |
| Minimum power dissipation | 0.88 W |
| Coordination type | 1 |
Supply
| Rated control circuit supply voltage US | 24 V DC |
| Control supply voltage range | 19.2 V DC ... 30 V DC |
| Rated control supply current IS | 60 mA |
| Protective circuit | Surge protection |
| Protective circuit | Reverse polarity protection; Parallel polarity protection diode |
Insulation characteristics
| Rated Insulation Voltage | 550 V |
| Rated surge voltage | 6 kV |
| Overvoltage category | III |
| Degree of pollution | 2 |
| Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit | Safe isolation (IEC 60947-1) |
| Isolation characteristics between the control input and control supply voltage to auxiliary circuit | Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC |
Emergency tripping
| Operate threshold | > 33 A |
| Response time | < 0.5 s |
AC output
| Rated operating voltage Ue | 500 V AC |
| Operating voltage range | 42 V AC ... 550 V AC |
| Rated operating current Ie | 3 A (AC-51) |
| Rated operating current Ie | 3 A (AC-53a) |
| Mains frequency | 50/60 Hz |
| Load current range | 180 mA ... 3 A (see to derating) |
| Trigger characteristic in acc. with IEC 60947-4-2 | Class 10 |
| Cooling time | 20 min. (for auto reset) |
| Leakage current | 0 mA |
| Protective circuit | Surge protection; Varistor |
Control circuits
| Connection Method | Push-in connection |
| Stripping length | 10 mm |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 14 |
Load circuit
| Connection Method | Push-in connection |
| Stripping length | 10 mm |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 14 |
Signaling
| Status display | Yellow LED |
| Operating voltage display | Green LED |
| Error indication | Red LED |
Dimensions
| Width | 22.5 mm |
| Height | 107.5 mm |
| Depth | 114 mm |
Material specifications
| Flammability rating according to UL 94 | V0 (Housing) |
Ambient conditions
| Degree of Protection | IP20 |
| Ambient Temperature (Operation) | -5 °C ... 60 °C (observe derating) |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m |
UKCA
| Certificate | UKCA-compliant |
UL approval
| Certificate | NLDX.E228652 |
| Certificate | NRNT.E172140 |
UL data
| SCCR | 100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault))) |
| SCCR | 5 kA (480 V AC (fuse: 20 A RK5 (standard fault))) |
| FLA | 3 A (480 V AC) |
| Group installation | 20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded) |
| Group installation | 30 A (class CC or J, SCCR 100kA (480 V AC), #24 - 14 AWG max, solid and stranded) |
| Category code | NLDX / NRNT |
| Horsepower ratings | 0.5 hp (208 V AC) |
| Horsepower ratings | 0.5 hp (230 V AC) |
| Horsepower ratings | 0.5 hp (240 V AC) |
| Horsepower ratings | 1.5 hp (480 V AC) |
Standards/regulations
| Standards/regulations | IEC 60947-1 |
| Standards/regulations | EN 60947-4-2 |
Mounting
| Mounting Type | DIN rail mounting |
| Assembly instructions | alignable, for spacing see derating |
| Mounting Position | vertical (horizontal DIN rail, motor output below) |
Accessories
ME 22,5 TBUS 1,5/ 5-ST-3,81 GY - DIN rail connector, color: gray, nominal current: 8 A (parallel contacts), rated voltage (III/2): 125 V, number of positions: 5, product range: TBUS5-22,5.., pitch: 3.81 mm, mounting: DIN rail mounting, locking: without, mounting: without, type of packaging: packed in cardboard, Item with gold-plated contacts, bus connectors for connecting with electronics housings, 5 parallel contacts
Why Proax for Phoenix Contact 2905146?
Proax is an authorized distributor of Phoenix Contact 2905146 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended