Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
2903908
Weight
0.288 kg
Series ELR-H

ELR H5-I-PT- 24DC/500AC-0,6 - Hybrid motor starter

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, and push-in connection.

  • 22.5 mm wide
  • Reduction in wiring
  • Space saving
  • Long service life
  • 3-phase loop bridges
  • Adjustable current for bimetal function
  • Low-wear switching
Technical Specifications

Notes

Notes on operationIf this device is to be used in combination with the CrossPowerSystem power distribution board, the device mount for the 16 A fuse (order designation: EM-CPS-DA-22,5F/16A; order number: 1002668) is required in order to attach the hybrid motor starter to the power distribution board.

Product properties

Product familyCONTACTRON
Operating mode100% operating factor

Electrical properties

Number of phases3
Motor starter typeReversing starter
Maximum power dissipation for nominal condition0.4 W
Switching frequency≤ 2 Hz (Load-dependent)
Maximum power dissipation1.5 W
Minimum power dissipation1.1 W
Coordination type1

Supply

Rated control circuit supply voltage US24 V DC
Control supply voltage range19.2 V DC ... 30 V DC
Rated control supply current IS40 mA
Protective circuitSurge protection
Protective circuitReverse polarity protection

Insulation characteristics

Rated Insulation Voltage500 V
Rated surge voltage6 kV
Overvoltage categoryIII
Degree of pollution2
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuitSafe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC (e.g., 230/400 V AC, 277/480 V AC)
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuitBasic insulation (IEC 60947-1) at operating voltage 300 V AC ... 500 V AC
Isolation characteristics between the control input and control supply voltage to auxiliary circuitSafe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC

Control

Input nameControl input right/left
Rated actuating voltage UC24 V DC
Triggering voltage range19.2 V DC ... 30 V DC
Rated actuating current IC5 mA (Input type 1)
Switching threshold9.6 V (“0” signal)
Switching threshold19.2 V (“1” signal)
Typical turn-off time< 30 ms
Protective circuitReverse polarity protection

AC output

Rated operating voltage Ue500 V AC
Operating voltage range42 V AC ... 550 V AC
Rated operating current Ie0.6 A (AC-51)
Rated operating current Ie0.6 A (AC-53a)
Mains frequency50/60 Hz
Load current range75 mA ... 600 mA (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2Class 10A
Cooling time20 min. (for auto reset)
Leakage current0 mA
Protective circuitSurge protection

Acknowledge output

NoteConfirmation: floating change-over contact, signal contact
Contact switching type1 changeover contact
Switching capacity in accordance with IEC 60947-5-13 A (230 V, AC15)
Switching capacity in accordance with IEC 60947-5-12 A (24 V, DC13)

Control circuits

Connection MethodPush-in connection
Stripping length10 mm
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14

Load circuit

Connection MethodPush-in connection
Stripping length10 mm
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14

Signaling

Status displayYellow LED
Operating voltage displayGreen LED
Error indicationRed LED

Dimensions

Width22.5 mm
Height107.5 mm
Depth114 mm

Material specifications

Flammability rating according to UL 94V0 (Housing)

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-25 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m

UKCA

CertificateUKCA-compliant

UL approval

CertificateNLDX.E228652

UL data

SCCR100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
SCCR5 kA (500 V AC (fuse: 20 A RK5 (standard fault)))
FLA0.6 A (500 V AC)
Group installation20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
Group installation30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded)
Category codeNLDX / NRNT

Standards/regulations

Standards/regulationsIEC 60947-1
Standards/regulationsIEC 60947-4-2

Mounting

Mounting TypeDIN rail mounting
Assembly instructionsalignable, for spacing see derating
Mounting Positionvertical (horizontal DIN rail, motor output below)
Accessories

Why Proax for Phoenix Contact ELR H5-I-PT- 24DC/500AC-0,6?

Proax is an authorized distributor of Phoenix Contact ELR H5-I-PT- 24DC/500AC-0,6 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Alternate NamesELRH5IPT24DC500AC06
Pack Size1
Recommended

Available for order