Proax

Currency
0 Items
proax logo
Cart
Phoenix ContactOfficial Distributor

By Phoenix Contact

SKU
MPN
MACX MCR-TS-I-OLP-SP
Weight
0.205 kg

MACX MCR-TS-I-OLP-SP - Temperature measuring transducer

Output loop-powered temperature transducer for transmitting up to 2 sensor signals from RTD and TC sensors, as well as from resistance and voltage sensors via 4 mA ... 20 mA. HART, Signal conditioners with SIL functional safety, Standard configuration, Safety Integrity Level (SIL, IEC 61508): 2, Systematic Capability: 3, Push-in connection

Technical Specifications

Product properties

Product familyMACX Analog
No. of channels2
TypeSignal conditioners with SIL functional safety
ConfigurationSoftware
ConfigurationHART

Insulation characteristics

Overvoltage categoryII
Pollution degree2

Electrical properties

Step response (0–99%)0.8 s (TC)

Electrical isolation Input/output

Test voltage2 kV AC (50 Hz, 60 s)

Supply

Supply Voltage Rangeloop-powered, no external supply necessary
Supply Voltage Range12 V DC ... 42 V DC (Standard)
Supply Voltage Range12 V DC ... 32 V DC (SIL active)

Signal

Input SignalTemperature

Measurement

Number of Inputs2
Input voltage range-20 mV ... 100 mV (Minimum measuring span: 5 mV)
Sensor types (RTD) that can be usedPt, Ni, Cu sensors: 2, 3, 4-wire
Sensor types that can be used (TC)A, B, C, D, E, J, K, L, N, R, S, T, U
Temperature measuring range-250 °C ... 2500 °C (Range depending on the sensor type)
Temperature measuring range-200 °C ... 850 °C (Pt 100)
Temperature measuring range> 10 K (RTD)
Temperature measuring range> 50 K (TC)
Linear resistance measuring range10 Ω ... 2000 Ω (Minimum measuring span: 10 Ω)

Signal: Current

Configurable/programmableno
Current Output Signal4 mA ... 20 mA
Current Output Signal20 mA ... 4 mA
Max. current output signal23 mA
Load(UL - 11 V) / 0,023 A
HART codingFSK ± 0.5 mA
HART version7
Transmission Speed1200 Baud
Mains frequency filter50/60 Hz
Communication resistance≥ 250 Ω
Switch-on delay 10 s (HART)
Switch-on delay 28 s (Measured value)

Connection data

Connection MethodPush-in connection
Stripping length8 mm
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16

Ex data

Ex installation (EPL)Gc
Ex installation (EPL)Div. 2

Data communication (bypass)

Protocols SupportedHART

Signaling

Status displayLED red

Dimensions

Width12.5 mm
Height116 mm
Depth113.7 mm
Depth NS 35/7,5114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)

Material specifications

Colorgray (RAL 7042)

Ambient conditions

Degree of ProtectionIP20
Ambient Temperature (Operation)-40 °C ... 85 °C
Ambient Temperature (Operation)-40 °C ... 70 °C (SIL active)
Ambient temperature (storage/transport)-40 °C ... 100 °C
Altitude≤ 4000 m (Above sea level)
Climatic classB2
Permissible humidity (operation)5 % ... 95 % (non-condensing)

CE

CertificateCE-compliant

ATEX

Identification II 3G Ex nA IIC T6...T4 Gc

UL, USA/Canada

IdentificationUL 61010 Recognized

FM

IdentificationNI, Class I, Div. 2, Groups A, B, C, D

CSA

IdentificationNI / Class I / Div. 2 / ABCD T6/T5/T4

Shipbuilding approval

CertificateDNV GL TAA00002GX

Safety Integrity Level (SIL, IEC 61508)

Identification2

Systematic Capability

Identification3

DNV GL data

TemperatureD
HumidityB
VibrationA
EMCB
EnclosureA

Mounting

Mounting TypeDIN rail mounting
Accessories

Why Proax for Phoenix Contact 2908664?

Proax is an authorized distributor of Phoenix Contact 2908664 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.

Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!

Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information

Pack Size1
Recommended

Not in stock

Request lead time or order—we'll ensure quick delivery

Phoenix Contact Availability