VAL-MS-AR 350 VF - Type 2 surge arrester
The VAL-MS-AR 350 VF is a hybrid SPD with a gas discharge tube in series with a metal oxide varistor and thermal monitor, ideal for applications where no leakage current can be tolerated.The VAL-MS BE-AR base provides a disconnect that separates the field wire from the protected mode for field diagnosis. Independent input and output terminals on the same side with ground terminals on the opposite end. All terminals are high-current screw clamping for stripped or ferruled, solid or stranded wires.
Product properties
Product family | VALVETRAB MS |
IEC test classification | II |
IEC test classification | T2 |
EN type | T2 |
Type | DIN rail module, two-section, divisible |
Surge protection fault message | optical |
Electrical properties
Nominal frequency fN | 50 Hz (60 Hz) |
Nominal voltage UN | 230 V AC |
Nominal current IN | 76 A (at 30°C ambient temperature) |
Connection data
Connection Method | Screw terminal block |
Tightening torque | 3 Nm ... 4.5 Nm (Ground) |
Tightening torque | 1.5 Nm ... 1.8 Nm (House) |
Tightening torque | 2.5 Nm ... 3 Nm (Field) |
Conductor cross section flexible | 1.5 mm² ... 35 mm² (16 mm strip length) |
Conductor cross section flexible | 0.5 mm² ... 15 mm² (10 mm strip length) |
Conductor cross section flexible | 1.5 mm² ... 25 mm² (14 mm strip length) |
Conductor cross section rigid | 1.5 mm² ... 35 mm² (16 mm strip length) |
Conductor cross section rigid | 0.5 mm² ... 15 mm² (10 mm strip length) |
Conductor cross section rigid | 1.5 mm² ... 25 mm² (14 mm strip length) |
Conductor cross section AWG | 15 ... 2 (16 mm strip length) |
Conductor cross section AWG | 20 ... 6 (10 mm strip length) |
Conductor cross section AWG | 12 ... 4 (14 mm strip length) |
Dimensions
Width | 17.7 mm |
Height | 153 mm |
Depth | 75 mm |
Material specifications
Color | black (RAL 9005) |
Color | black (RAL 9005) |
Flammability rating according to UL 94 | V0 |
Housing Material | PA |
Protective circuit
Direction of action | 1L-N/PE |
Nominal frequency fN | 50 Hz (60 Hz) |
Maximum continuous voltage UC | 350 V AC |
Rated load current IL | 55 A (with 6 AWG) |
Nominal discharge current In (8/20) µs | 10 kA |
Maximum discharge current Imax (8/20) µs | 20 kA |
Total discharge current Itotal (8/20) µs | 20 kA |
Total discharge current Itotal (10/350) µs | 3 kA |
Voltage protection level Up | ≤ 1.2 kV |
Total surge current (10/350) µs | 3 kA |
Total surge current (8/20) µs | 15 kA |
Max. backup fuse with branch wiring | 125 A (gG) |
Ambient conditions
Degree of Protection | IP20 (when disconnect closed) |
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -40 °C ... 80 °C |
Altitude | max. 3000 m |
Permissible humidity (operation) | 5 % ... 95 % |
Permissible humidity (storage/transport) | 5 % ... 95 % |
Shock (operation) | 10g |
Vibration (Operation) | 2g (0 Hz ... 200 Hz) |
Mounting
Mounting Type | DIN rail mounting with additional retaining screw |
Why Proax for Phoenix Contact 2801489?
Proax is an authorized distributor of Phoenix Contact 2801489 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Pack Size | 1 |
- VAL-MS-AR-T1/T2 75 - The VAL-MS-AR T1/T2 75 is a high-capacity SPD for Type 1 lightning as well as Type 2 switching surge currents, ideal for applications with both high load currents and high surge risk.VAL-MS BE-AR base provides a disconnect that separates the field wire from the protected mode for field diagnosis. Independent input and output terminals on the same side with ground terminals on the opposite end. All terminals are high-current screw clamping for stripped or ferruled, solid or stranded wires.
- VAL-MS-AR-T1/T2 75/FM - The VAL-MS-AR T1/T2 75/FM is a high-capacity SPD for Type 1 lightning as well as Type 2 switching surge currents, ideal for applications with high load currents and high surge risk.The VAL-MS BE-AR/FM base provides a disconnect that separates the field wire from the protected mode for field diagnosis and dry contacts for remote function monitoring. The base has independent input and output terminals on the same side with ground terminals on the opposite end. All terminals are high-current screw clamping for stripped or ferruled, solid or stranded wires.