2703014
SKU
PHX2703014
MPN
INJ 2112-T
Weight
0.459 kg
Series INJ
INJ 2112-T - Injector
PoE injector, 60 W, RJ45 jack on IDC terminal blocks, 10/100/1000 Mbps, DIN rail mounting, IP20, potential separation, shield contacting with strain relief, shield current monitoring, surge protection
- Extended temperature range of -40 °C ... +75 °C
- Fast connection of the PoE cable
- Wiring space covered with front panel cover
- Integrated surge protection to ensure high system availability
- Electrical isolation of the internal power supply unit for protection against short circuits on the PoE side
- 10/100/1000 Mbps
Technical Specifications
Dimensions
| Width | 30.2 mm |
| Height | 130 mm |
| Depth | 120 mm |
Utilization restriction
| CCCex note | Use in potentially explosive areas is not permitted in China. |
Material specifications
| Color (Housing) | light grey (RAL 7035) |
| Material (Housing) | Plastic |
| Flammability rating according to UL 94 | V0 |
Mounting
| Mounting Type | DIN rail mounting |
| Mounting Position | vertical |
Interfaces
| Basic Functions | PSE/Midspan, compliant with IEEE 802.3af, at |
Data: Power over Ethernet
| Serial transmission speed | 10/100/1000 Mbps |
| Frequency Range | 125 MHz |
| Connection Method | IDC connection |
| Note on the connection method | CAT5e |
| No. of channels | 1 |
| Pin assignment | 1:1 |
| Transmission length | 100 m (including patch cables) |
| Single conductor/terminal point, rigid | 0.14 mm² ... 0.34 mm² |
| Single-wire/terminal point, flexible | 0.14 mm² ... 0.34 mm² |
| Max. AWG conductor cross section, flexible | 22 |
| Min. AWG conductor cross section, flexible | 26 |
| Single-wire/terminal point, rigid AWG max. | 22 |
| Single-wire/terminal point, rigid AWG min. | 26 |
| Wire diameter incl. insulation | 1.6 mm (Terminal block is tested with PVC insulation - other insulation materials available on request) |
| Frequency of connections between conductors of the same cross section | 10 |
| Output nominal voltage | 54 V DC (PoE) |
| Output Power | 60 W |
| Maximum output power | 75 W (UL) |
Data: Ethernet
| Connection Method | RJ45 jack |
| Note on the connection method | CAT5e |
Product properties
| IEC test classification | C2 |
| MTTF | 1797 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
| MTTF | 733 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) |
| MTTF | 283 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) |
Electrical properties
| Electrical isolation | VCC // SCM + FE // PoE |
| Maximum power dissipation for nominal condition | 12 W (at 18 V DC) |
| Maximum power dissipation for nominal condition | 9 W (24 V DC ... 48 V DC) |
| Test voltage data interface/power supply | 1.5 kV AC (50 Hz, 1 min.) |
Supply
| Supply Voltage Range | 18 V DC ... 57 V DC |
| Nominal Supply Voltage | 24 V DC (SELV/PELV, restrictions for ATEX applications) |
| Nominal Supply Voltage | 48 V DC |
| Max. current consumption | 4.2 A |
| Max. current consumption | 2.73 A (24 V DC, Ex areas in accordance with UL-HazLoc) |
| Max. current consumption | 1.34 A (48 V DC, Ex areas in accordance with UL-HazLoc) |
| Power consumption | ≤ 75 W |
| Protective circuit | Reverse polarity protection |
Function
| Designation | Shield current monitoring |
| Switch-on threshold | ≥ 30 mA |
| Local diagnostics | Yellow LED |
| Precision | ± 5 % |
| Response time | 3 s |
| Current | ≤ 2 A |
| Power consumption | 270 mW (Shield current monitoring) |
Supply
| Connection Method | Push-in connection |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 2.5 mm² |
| Single conductor/terminal point, rigid | 0.2 mm² ... 2.5 mm² |
| Single-wire/terminal point, flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section, flexible [AWG] | 20 ... 12 |
Ambient conditions
| Degree of Protection | IP20 (Manufacturer's declaration) |
| Ambient Temperature (Operation) | -40 °C ... 45 °C (75°C, observe derating) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
| Altitude | ≤ 2000 m (Restrictions for ATEX applications) |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Air pressure (operation) | 80 kPa ... 110 kPa (Restrictions for ATEX applications) |
Standards and Regulations
| Standards/regulations | IEC 61643-21 |
CE
| Certificate | CE-compliant |
ATEX
| Identification | II 3G Ex ec nC IIC T4 Gc |
| Certificate | PxCIF19ATEX2703014X |
| Note | Please follow the special installation instructions in the documentation! |
UL, USA/Canada
| Identification | Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 |
| Identification | Class I, Div. 2, Groups A, B, C, D |
UL, USA
| Certificate | UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4 |
UL, Canada
| Certificate | CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16 |
Corrosive gas test
| Identification | ISA-S71.04-1985 G3 Harsh Group A |
Power over Ethernet
| Identification | IEEE 802.3af |
| Identification | IEEE 802.3at |
EMC data
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Electromagnetic compatibility | FCC Part 15B Class A |
| Electromagnetic compatibility | CISPR 22 |
Electrostatic discharge
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | ± 6 kV (Test Level 3) |
| Discharge in air | ± 8 kV (Test Level 3) |
| Indirect discharge | ± 6 kV |
| Comments | Criterion B |
Electromagnetic HF field
| Standards/regulations | EN 61000-4-3 |
| Frequency Range | 80 MHz ... 3 GHz (Test Level 3) |
| Field intensity | 10 V/m |
| Comments | Criterion A |
Fast transients (burst)
| Standards/regulations | EN 61000-4-4 |
| Input | ± 2.2 kV (1 minute) |
| Signal | ± 2.2 kV (1 minute) |
| Comments | Criterion B |
Surge current load (surge)
| Standards/regulations | EN 61000-4-5 |
| Input | ± 0.5 kV |
| Signal | ± 1 kV (Data line, asymmetrical) |
| Signal | ± 2 kV (I/O cable on field side only, asymmetric) |
| Comments | Criterion B |
Conducted interference
| Standards/regulations | EN 61000-4-6 |
| Frequency Range | 0.15 MHz ... 80 MHz |
| Comments | Criterion A |
| Voltage | 10 V |
Emitted interference
| Standards/regulations | EN 61000-6-4 |
| Comments | Class A, industrial applications |
| Standards/regulations | EN 61000-6-3 |
| Comments | Class B, domain of use: residential and small commercial |
Functionality
| Basic Functions | PSE/Midspan, compliant with IEEE 802.3af, at |
Signaling
| Optical representation | Yellow LED |
Why Proax for Phoenix Contact 2703014?
Proax is an authorized distributor of Phoenix Contact 2703014 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
| Pack Size | 1 |
Recommended