Series INJ
INJ 1110-T - Injector
PoE injector, 60 W, two RJ45 jacks, 10/100/1000 Mbps, DIN rail mounting, IP20, expanded temperature range of -40°C ... 75°C, potential separation
- Extended temperature range of -40 °C ... +75 °C
- Extended supply voltage range of 18 V DC ... 57 V DC, redundant
- Electrical isolation of the internal power supply unit for protection against short circuits on the PoE side
- 10/100/1000 Mbps
Technical Specifications
Dimensions
Width | 30.2 mm |
Height | 130 mm |
Depth | 120 mm |
Utilization restriction
CCCex note | Use in potentially explosive areas is not permitted in China. |
Material specifications
Color (Housing) | light grey (RAL 7035) |
Material (Housing) | Plastic |
Flammability rating according to UL 94 | V0 |
Mounting
Mounting Type | DIN rail mounting |
Mounting Position | vertical |
Interfaces
Basic Functions | PSE/Midspan, compliant with IEEE 802.3af, at |
Data: Power over Ethernet
Serial transmission speed | 10/100/1000 Mbps |
Frequency Range | 125 MHz |
Connection Method | RJ45 jack |
Note on the connection method | CAT5e |
No. of channels | 1 |
Pin assignment | 1:1 |
Transmission length | 100 m (including patch cables) |
Output nominal voltage | 54 V DC (PoE) |
Output Power | 60 W |
Maximum output power | 75 W (UL) |
Data: Ethernet
Connection Method | RJ45 jack |
Note on the connection method | CAT5e |
Product properties
MTTF | 3062 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
MTTF | 1397 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) |
MTTF | 558 Years (SN 29500 standard, temperature 40°C, operating cycle 100%) |
Electrical properties
Electrical isolation | VCC // FE // PoE |
Maximum power dissipation for nominal condition | 12 W (at 18 V DC) |
Maximum power dissipation for nominal condition | 9 W (24 V DC ... 48 V DC) |
Test voltage data interface/power supply | 500 V (50 Hz, 1 min.) |
Supply
Supply Voltage Range | 18 V DC ... 57 V DC |
Nominal Supply Voltage | 24 V DC (SELV/PELV, restrictions for ATEX applications) |
Nominal Supply Voltage | 48 V DC |
Max. current consumption | 4.2 A |
Max. current consumption | 2.73 A (24 V DC, Ex areas in accordance with UL-HazLoc) |
Max. current consumption | 1.34 A (48 V DC, Ex areas in accordance with UL-HazLoc) |
Power consumption | ≤ 75 W |
Protective circuit | Reverse polarity protection |
Function
Current | ≤ 2 A |
Supply
Connection Method | Push-in connection |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 2.5 mm² |
Single conductor/terminal point, rigid | 0.2 mm² ... 2.5 mm² |
Single-wire/terminal point, flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section, flexible [AWG] | 20 ... 12 |
Stripping length | 10.00 mm |
Ambient conditions
Degree of Protection | IP20 (Manufacturer's declaration) |
Ambient Temperature (Operation) | -40 °C ... 45 °C (75°C, observe derating) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
Altitude | ≤ 2000 m (Restrictions for ATEX applications) |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Air pressure (operation) | 80 kPa ... 110 kPa (Restrictions for ATEX applications) |
CE
Certificate | CE-compliant |
ATEX
Identification | II 3 G Ex ec IIC T4 Gc |
Certificate | PxCIF19ATEX2703010X |
Note | Please follow the special installation instructions in the documentation! |
UL, USA/Canada
Identification | Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 |
Identification | Class I, Div. 2, Groups A, B, C, D |
UL, USA
Certificate | UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4 |
UL, Canada
Certificate | CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16 |
Corrosive gas test
Identification | ISA-S71.04-1985 G3 Harsh Group A |
Power over Ethernet
Identification | IEEE 802.3af |
Identification | IEEE 802.3at |
EMC data
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Electromagnetic compatibility | FCC Part 15B Class A |
Electromagnetic compatibility | CISPR 22 |
Electrostatic discharge
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV (Test Level 3) |
Discharge in air | ± 8 kV (Test Level 3) |
Comments | Criterion B |
Electromagnetic HF field
Standards/regulations | EN 61000-4-3 |
Frequency Range | 80 MHz ... 3 GHz (Test Level 3) |
Field intensity | 10 V/m |
Comments | Criterion A |
Fast transients (burst)
Standards/regulations | EN 61000-4-4 |
Input | ± 2.2 kV (1 minute) |
Signal | ± 2.2 kV (1 minute) |
Comments | Criterion B |
Surge current load (surge)
Standards/regulations | EN 61000-4-5 |
Input | ± 0.5 kV |
Signal | ± 1 kV (Data line, asymmetrical) |
Signal | ± 2 kV (I/O cable on field side only, asymmetric) |
Comments | Criterion B |
Conducted interference
Standards/regulations | EN 61000-4-6 |
Frequency Range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V |
Emitted interference
Standards/regulations | EN 61000-6-4 |
Comments | Class A, industrial applications |
Standards/regulations | EN 61000-6-3 |
Comments | Class B, domain of use: residential and small commercial |
Criteria
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Functionality
Basic Functions | PSE/Midspan, compliant with IEEE 802.3af, at |
Why Proax for Phoenix Contact 2703010?
Proax is an authorized distributor of Phoenix Contact 2703010 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended