Official Distributor
SKU
MPN
AXL F BK PN XC
Weight
0.23 kg
AXL F BK PN XC - Bus coupler
Axioline F, Bus coupler, PROFINET, RJ45 jack, Extreme conditions version, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connector
- 2 Ethernet ports (with integrated switch)
- Conformance with PROFINET specification V2.2
- Supports PROFIsafe
- PROFINET RT and IRT
- Minimum cycle time of PROFINET for RT and IRT is 250 μs
- Firmware can be updated
- Runtime in bus coupler is negligible (almost 0 µs)
- Typical cycle time of the Axioline F local bus is around 10 μs
- Web-based management
- Supports the operation of Axioline Smart Elements
- Supports Diag+
- Can be used under extreme ambient conditions
- Extended temperature range of -40 °C ... +70 °C (see “Tested successfully: use under extreme ambient conditions” in the data sheet)
- Partially coated PCBs
Technical Specifications
Dimensions
Width | 45 mm |
Height | 126.1 mm |
Depth | 74 mm |
Note on dimensions | The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715). |
PROFINET
Number of interfaces | 2 |
Connection Method | RJ45 jack |
Note on the connection method | Auto negotiation and autocrossing |
Transmission Speed | 100 Mbps (full duplex) |
Transmission physics | Ethernet in RJ45 twisted pair |
Axioline F local bus
Number of interfaces | 1 |
Connection Method | Bus base module |
Transmission Speed | 100 Mbps |
Service
Number of interfaces | 1 |
Connection Method | Micro USB type B |
System limits
Number of supported devices | max. 63 (per station) |
Number of local bus devices that can be connected | max. 63 |
PROFINET
Device function | PROFINET device |
Specification | Version 2.2 |
Conformance class | Conformance-Class C |
Device ID | 1000hex |
Vendor ID | 00B0hex |
Product properties
Product family | Axioline F |
Type | block modular |
Mounting Position | any (observe temperature derating) |
Scope of delivery | including bus base module and Axioline F connector |
Special Properties | Extreme conditions version |
Insulation characteristics
Overvoltage category | II (IEC 60664-1, EN 60664-1) |
Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
Potentials: Communications power UL feed-in (the supply of the Axioline F local bus UBus is generated from UL)
Supply Voltage | 24 V DC |
Supply Voltage Range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 570 mA (2.0 A on UBus, UL = 24 V) |
Power consumption | max. 14 W (2.0 A on UBus, UL = 24 V) |
Protective circuit | Surge protection; electronic |
Protective circuit | Reverse polarity protection; electronic |
Potentials: Axioline F local bus supply (UBus)
Supply Voltage | 5 V DC (via bus base module) |
Power Supply Unit | max. 2 A |
Electrical isolation/isolation of the voltage ranges
Test voltage: PROFINET interface 1 / PROFINET interface 2 | 1500 V AC, 50 Hz, 1 min. |
Test voltage: PROFINET interface 1 / 24 V communications voltage (UL) feed-in | 1500 V AC, 50 Hz, 1 min. |
Test voltage: PROFINET interface 2 / 24 V communications voltage (UL) feed-in | 1500 V AC, 50 Hz, 1 min. |
Test voltage: PROFINET interface 1 / functional ground | 1500 V AC, 50 Hz, 1 min. |
Test voltage: PROFINET interface 2 / functional ground | 1500 V AC, 50 Hz, 1 min. |
Test voltage: 24 V communications voltage (UL) feed-in / functional ground | 500 V AC, 50 Hz, 1 min. |
Connection technology
Connection name | Axioline F connector |
Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
Conductor connection
Connection Method | Push-in connection |
Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Stripping length | 8 mm |
Axioline F connector
Connection Method | Push-in connection |
Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² |
Conductor cross section, flexible | 0.2 mm² ... 1.5 mm² |
Conductor cross section AWG | 24 ... 16 |
Stripping length | 8 mm |
Ambient conditions
Ambient Temperature (Operation) | -25 °C ... 60 °C (Mounting position: wall mounting on horizontal DIN rail) |
Ambient Temperature (Operation) | -25 °C ... 55 °C (Mounting position: any) |
Ambient Temperature (Operation) | -40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.) |
Degree of Protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Standards and Regulations
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting
Mounting Type | DIN rail mounting |
Mounting Position | any (observe temperature derating) |
Accessories
Why Proax for Phoenix Contact 2701222?
Proax is an authorized distributor of Phoenix Contact 2701222 and one of Phoenix Contact's largest distributors in North America. Our highly skilled in-house technical team is ready to assist with any technical needs.
Have a question in mind? to help you get the right product as quickly as possible for your project. We're always here to help!
Short Lead Time
Highly Trained Staff
Live Chat
Technical Support
Local Inventory
60+ Years Experience
Additional Information
Pack Size | 1 |
Recommended